Skip to main content
SolaX X1-SMT-6K-G2

SolaX X1-SMT-6K-G2

6 kW Grid-tie Single-phase
Datasheet PDF
Rated AC (kW)
6.00
Strong · top 12%
Euro eff. (%)
97.5
Typical · median 97.1%
MPPT
3
Strong · top 5%
Max DC (V)
600
Typical · median 600 V
Weight (kg)
19.5
Typical · median 18.0 kg
Warranty (yrs)
-
Not published

The X1-SMART-G2 series comprises single-phase inverters built for residential solar installations, designed around flexible expansion and everyday ease of use. What sets it apart is parallel operation of up to 5 inverters without the need for an external EMS, letting homeowners scale system capacity as household energy demand grows, without having to replace the unit. With smart load management for devices such as heat pumps and EV chargers, the series helps make the best use of self-generated power and reduces reliance on the grid. A design featuring three independent MPPT trackers suits installations with roof sections facing different orientations, while 200% PV oversizing gives system designers real freedom in matching module capacity to inverter power. Built-in I-V curve diagnostics make it easy to spot string-level issues without extra equipment, cutting down on service time. Safety is reinforced by Type II surge protection on both the AC and DC sides, plus an optional AFCI function that detects arc faults. It's a solid fit for installers and homeowners who value straightforward plug-and-play wiring along with near real-time energy consumption monitoring.

Ranking

1,005 inverters from 3 to 6 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.5% 97.1% Typical 155
MPPT trackers 3 2 Strong · top 5% 11
Max DC input voltage 600 V 600 V Typical 261
Weight per kW 3.2 3.9 Typical 366
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 6 kW Continuous output
Max apparent power 6.60 kVA
Phases Single-phase
Nominal AC voltage 230 V
Max AC current 30.0 A
Grid frequency 50 Hz Range 50±5 Hz / 60±5 Hz
Power factor ~1 (0.8 lagging to 0.8 leading)
Harmonic distortion (THD) 3.0 %
Max DC input power 12.00 kW DC/AC ratio 2.00
Max DC voltage 600 V Caps the string length
MPPT voltage range 40 to 560 V
Start-up voltage 50 V
MPPT trackers 3 1 string each
Max input current per MPPT 20.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 25.0 A Must exceed the panel's Isc
European efficiency 97.5 % Weighted across part loads
Max efficiency 98.2 % Best single operating point
Dimensions 370 × 515 × 170 mm Height × width × depth
Weight 19.5 kg 3.2 kg per kW
Enclosure IP66
Cooling natural
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernet
Protocols RS485DRMCTMeterWiFiLAN4GWiFi+LANWiFi+4G
Protection AFCISurge protection
Certifications IEC/EN 62109-1/-2AS 4777.2:2020G99INMETROIEC61727

Pros and cons

5 positive · 2 caution
What owners get
Parallel operation up to 5 units, no EMS

The X1-SMART-G2 series supports connecting up to 5 inverters in parallel without an external EMS, enabling single-phase installations to scale to roughly 50 kW without hardware replacement - uncommon in this residential inverter class.

200% PV oversizing and 3x MPPT trackers

Three independent MPPT trackers plus allowance for PV module oversizing up to 200% relative to inverter power give installers significant design flexibility for roofs with multiple orientations and azimuths.

Built-in I-V curve diagnostics

Integrated I-V curve scanning allows string-level fault detection (e.g., shading, damaged modules) without additional meters, reducing service time compared to competing models lacking this feature.

Type II AC/DC surge protection plus optional AFCI

The series includes Type II surge protection on both AC and DC sides and optional AFCI arc-fault detection, matching safety standards used by Tier-1 manufacturers such as Huawei or Fronius.

Smart load management

Native prioritization of loads such as heat pumps or EV chargers maximizes PV self-consumption without requiring a separate external EMS controller, lowering total system cost.

Trade-offs
AFCI is optional, not standard

Arc-fault circuit detection (AFCI) is an optional feature rather than built in by default as with some competitors (e.g., SMA Sunny Boy), requiring extra configuration or cost where this protection is mandated.

T-variant models limited to 2 MPPT

Per manufacturer documentation, the 'T' variants (e.g., 7KT-10KT) have only two MPPT trackers, while the rest of the series offers three - this can limit design flexibility for certain roof configurations depending on the chosen variant.

Alternatives

All SolaX inverters
Inverter Power Euro eff. MPPT Weight Difference
SolaX X1-SMT-6K-G2 6 kW 97.5% 3 19.5 kg You are here
SolarEdge SE6000H (HD‑Wave, single phase) 6 kW 99.0% - 10.6 kg +1.5 pp efficiency, 8.9 kg lighter
SolarEdge EV Charging Single Phase Inverter SE6000H (aka H6000SE / SE6000H) 6 kW 99.0% - 11.9 kg +1.5 pp efficiency, 7.6 kg lighter
XG6KTR-S 6 kW 98.3% 2 12.0 kg +0.8 pp efficiency, -1 MPPT, 7.5 kg lighter
BNT006KTL 6 kW 98.0% 2 16.0 kg +0.5 pp efficiency, -1 MPPT, 3.5 kg lighter
StecaGrid 6013 6 kW 98.0% 1 12.0 kg +0.5 pp efficiency, -2 MPPT, 7.5 kg lighter
SPI6K-B 6 kW 98.0% 2 18.5 kg +0.5 pp efficiency, -1 MPPT, 1.0 kg lighter
STT-6KTL-P 6 kW 98.0% 2 23.0 kg +0.5 pp efficiency, -1 MPPT, 3.5 kg heavier
HNS6000TL 6 kW 97.9% 2 10.0 kg +0.4 pp efficiency, -1 MPPT, 9.5 kg lighter

About the X1-SMART-G2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Can several X1-SMART-G2 inverters be connected in one installation without an additional EMS system?
Yes, the X1-SMART-G2 series supports parallel operation of up to 5 units without needing an external EMS system. The inverters communicate with each other directly, letting you scale installation capacity as household demand grows, for example after adding a heat pump or EV charger, without replacing an already installed unit with a larger one.
What does 200% PV oversizing mean on the X1-SMART-G2 inverters?
This is the maximum allowed PV array capacity relative to the inverter's nominal AC power output, reaching up to 200 percent. In practice, this gives system designers significant flexibility: more or higher-power modules can be installed than the inverter's rated power alone would suggest, boosting energy yield during low-irradiance periods without risking overload.
How does smart load management work on the X1-SMART-G2 for devices like a heat pump or EV charger?
The inverter automatically prioritizes self-generated power for selected home appliances, such as a heat pump or EV charger, switching them on when there is excess PV production. This way, more of the energy produced is consumed on-site, and grid draw is reduced, which translates into real savings on electricity bills.
What is I-V curve diagnostics on the X1-SMART-G2 and what is it used for?
This is a built-in function that measures the current-voltage characteristic of each PV string without requiring extra test equipment. It lets a technician quickly spot soiling, module damage, or wiring issues directly from app readings, shortening diagnosis time and reducing the number of service visits needed to locate a fault.
Is the X1-SMART-G2 suitable for a home with panels on roof sections facing different directions?
Yes, the design with three independent MPPT trackers allows strings with different orientation and tilt angles to be connected to a single unit. Each tracker optimizes its own string independently, so panels facing, for instance, east and west don't limit each other's output the way they could with a single shared tracker.
What protections does the X1-SMART-G2 series have, and is the AFCI option worth adding?
The inverters come with built-in Type II surge protection on both the AC and DC sides, guarding against voltage spikes from the grid or lightning strikes. The optional AFCI module detects arc faults in DC wiring that can lead to fires. It's especially worth adding for longer cable runs or installations on wooden roof structures.