Skip to main content
INVT XG6KTR-S

INVT XG6KTR-S

6 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
6.00
Strong · top 12%
Euro eff. (%)
98.3
Strong · top 3%
MPPT
2
Typical · median 2
Max DC (V)
1100
Strong · top 4%
Weight (kg)
12.0
Strong · 6.0 kg below median
Warranty (yrs)
-
Not published

The INVT XG3-15KTR-S series is a three-phase on-grid inverter built for residential and small commercial installations where configuration flexibility and operating safety both matter. The unit relies on a dual MPPT tracker, allowing independent management of two module strings with different orientation or shading - a direct answer to the common problem of complex roof geometries, where one string loses yield due to shade or a different tilt angle. A wide input voltage range makes it easier to match various panel configurations, including newer modules with higher voltages. Safety is handled through a built-in AFCI function that detects arc faults, plus Type II surge protection on both the DC and AC sides, shielding the installation from the effects of lightning strikes. The IP66-rated enclosure allows outdoor mounting without extra housing, even in harsh weather conditions. Low current harmonic distortion and a high power factor translate into stable interaction with the grid. Standard RS485 communication, along with optional WiFi, GPRS, and Ethernet, gives installers freedom to choose how they monitor system performance. It is a solution for installers looking for a reliable, versatile inverter for mixed-use projects, where durability and ease of servicing are the priority.

Ranking

1,005 inverters from 3 to 6 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.3% 97.1% Strong · top 3% 18
MPPT trackers 2 2 Typical 59
Max DC input voltage 1100 V 600 V Strong · top 4% 1
Weight per kW 2.0 3.9 Strong · top 11% 100
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 6 kW Continuous output
Max AC power 6.60 kW Short-term output above the rating
Max apparent power 6.60 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 9.6 A
Grid frequency 50 Hz
Power factor 0.8 leading ~ 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 9.60 kW DC/AC ratio 1.60
Max DC voltage 1100 V Caps the string length
MPPT voltage range 180 to 1000 V
Start-up voltage 200 V
MPPT trackers 2 1 string each
Max input current per MPPT 18.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 25.0 A Must exceed the panel's Isc
European efficiency 98.3 % Weighted across part loads
Max efficiency 98.4 % Best single operating point
Dimensions 390 × 481 × 190 mm Height × width × depth
Weight 12.0 kg 2.0 kg per kW
Enclosure IP66
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485WiFiGPRSEthernet
Protection AFCISurge protection
Certifications IEC/EN 62109-1/2IEC/EN 61000-6-1/3IEC61683IEC60068IEC61727/IEC62116EN50549CEI0-21C10/C11VDE 4105VDE 0124G98/G99RD244UNE217001UNE217002NC RfGTOR ErzeugerAS4777ABNTNB/T 32004BIS

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT for complex roof layouts

Two independent MPPT trackers (180-1000 V range, 18 A per tracker) support two strings with different orientation or shading without degrading overall system performance.

IP66 enclosure for outdoor mounting

IP66 protection rating allows outdoor installation without an additional enclosure, reducing installation cost and simplifying service compared to units requiring extra weatherproofing.

High max efficiency of 98.7%

Per the manufacturer's datasheet, the inverter reaches a maximum efficiency of 98.7%, a competitive figure within the 15 kW three-phase on-grid inverter class.

Flexible monitoring communication

Standard RS485 complemented by optional WiFi, GPRS, and Ethernet modules gives installers freedom to choose the remote monitoring method without switching platforms.

Type II DC/AC surge protection

Built-in Type II surge protection on both DC and AC sides shields the installation from lightning-induced surges, which matters for open-roof installations.

Trade-offs
Only 2 MPPT trackers

Competing tier-1 15 kW models (e.g., Huawei SUN2000-15KTL-M2 with 4 MPPT) offer more independent trackers, giving greater flexibility for complex string layouts than the two strings supported by the XG3-15KTR-S.

AFCI listed as an optional feature

Per the manufacturer's datasheet, arc-fault detection (AFCI) is an optional feature rather than standard equipment - some markets (e.g., California, Germany) require it as standard, which may add configuration or cost.

Alternatives

All INVT inverters
Inverter Power Euro eff. MPPT Weight Difference
INVT XG6KTR-S 6 kW 98.3% 2 12.0 kg You are here
SolarEdge SE6000H (HD‑Wave, single phase) 6 kW 99.0% - 10.6 kg +0.7 pp efficiency, 1.4 kg lighter
BNT006KTL 6 kW 98.0% 2 16.0 kg 4.0 kg heavier
StecaGrid 6013 6 kW 98.0% 1 12.0 kg -1 MPPT
SPI6K-B 6 kW 98.0% 2 18.5 kg 6.5 kg heavier
STT-6KTL-P 6 kW 98.0% 2 23.0 kg 11.0 kg heavier
HNS6000TL 6 kW 97.9% 2 10.0 kg -0.4 pp efficiency, 2.0 kg lighter
ASW6K-LT-G2 Pro 6 kW 97.9% 2 16.0 kg -0.4 pp efficiency, 4.0 kg heavier

About the XG3-15KTR-S series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum PV array power that can be connected to the INVT XG3-15KTR-S?
The XG3-15KTR-S supports DC input oversizing of up to about 160% of its rated power, meaning up to roughly 24 kW of panels against the 15 kW AC rated output. This allows installers to fit more modules than the inverter's nominal power would suggest, boosting energy yield during low-irradiance hours and making better use of available roof space.
What is the benefit of the dual MPPT trackers in the XG3-15KTR-S, and when should they be used?
The two independent MPPT trackers let you connect two separate strings with different orientation, tilt angle, or shading levels - for example, one half of the roof facing east and the other west. Each string is optimized independently, so shading or a different angle on one string doesn't drag down the performance of the other. This is especially useful on multi-pitch roofs or roofs with obstructions like chimneys or dormers.
Can the INVT XG3-15KTR-S inverter be installed outdoors?
Yes, the enclosure has an IP66 protection rating, meaning full resistance to dust and powerful water jets from any direction. The inverter can be mounted directly on an exterior wall or in a garage without an additional protective enclosure, even in humid or high-rainfall regions. It's still recommended to avoid locations with prolonged direct sun exposure to maximize the electronics' lifespan.
What does the AFCI feature in the XG3-15KTR-S do, and is it a mandatory safety feature?
AFCI (Arc Fault Circuit Interrupter) detects dangerous electrical arcing, such as from a damaged MC4 connector or a frayed DC cable, and automatically shuts down the array before a fire can start. Many EU countries already require or recommend this feature for rooftop installations. It comes built into the XG3-15KTR-S by default, so installers don't need to source a separate arc-fault protection device.
What monitoring options does the XG3-15KTR-S support?
The inverter has a built-in RS485 port for wired communication, plus optional WiFi, GPRS, and Ethernet modules. This gives installers flexibility based on site conditions - WiFi where home network coverage is good, GPRS where there's no wired internet, and Ethernet or RS485 for larger commercial installations that need a stable connection to the monitoring platform.
Does the XG3-15KTR-S protect the system against lightning-induced surges?
Yes, the inverter includes built-in Type II surge protection on both the DC and AC sides. This shields both the panels and DC wiring as well as the building's AC grid connection from voltage spikes caused by nearby lightning strikes or grid-side surges. This safety feature matters most in storm-prone regions, where it reduces the risk of damage to the inverter's sensitive electronics.