Skip to main content

Sigenergy 166M1

166.6 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
166.60
Typical for its class
Euro eff. (%)
98.4
Typical · median 98.5%
MPPT
9
Typical · median 8
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
100.0
Typical · median 99.0 kg
Warranty (yrs)
-
Not published

The Sigen PV series is built for large-scale commercial and industrial installations, where both raw power and ease of scaling matter equally. Inverters in this line feature a built-in energy management system (EMS), allowing up to 100 units to be connected in parallel without an external data logger - a real time-saver when designing and commissioning sprawling PV farms. Its high rated output sets a new industry benchmark for commercial-grade inverters, helping maximize project value while reducing the number of devices needed on site. Safety is reinforced by an advanced arc fault circuit interrupter (AFCI) with detection range up to 500 meters, a feature that matters most on large string arrays with long cable runs. An IP66-rated enclosure paired with smart air cooling allows outdoor deployment without extra protective housing, regardless of weather conditions. Nine independent MPPT trackers give installers the flexibility to adapt string configurations to irregular roof layouts or ground-mount terrain. The Sigen PV series fits projects where reliability, scalability, and low long-term maintenance costs are the priority throughout the lifetime of the solar installation.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.4% 98.5% Typical 96
MPPT trackers 9 8 Typical 70
Max DC input voltage 1100 V 1100 V Typical 113
Weight per kW 0.6 0.7 Typical 95
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 166.6 kW Continuous output
Max AC power 183.26 kW Short-term output above the rating
Max apparent power 183.26 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 278.4 A
Grid frequency 50 Hz
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 1.0 %
Max DC input power 270.00 kW DC/AC ratio 1.62
Max DC voltage 1100 V Caps the string length
MPPT voltage range 160 to 1000 V
Start-up voltage 180 V
MPPT trackers 9 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
European efficiency 98.4 % Weighted across part loads
Max efficiency 98.8 % Best single operating point
Dimensions 668 × 1019 × 340 mm Height × width × depth
Weight 100.0 kg 0.6 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 5000 m
Interfaces Wi-FiEthernet
Protocols WLANFast EthernetRS485Sigen CommMod (4G/3G/2G)
Protection AFCISurge protection
Certifications IEC/EN 62109-1IEC/EN 62109-2IEC/EN 61000-6-1IEC/EN 61000-6-2

Pros and cons

5 positive · 2 caution
What owners get
Built-in EMS for up to 100 units in parallel

The integrated energy management system allows parallel connection of up to 100 inverters without an external data logger, reducing design and commissioning time while cutting extra communication hardware costs for large PV farms.

AFCI detection range up to 500 m

The advanced arc-fault circuit interrupter (AFCI) with a detection range of up to 500 meters exceeds typical commercial/industrial segment standards, which matters for extensive PV strings and long cable runs on large rooftop and ground-mount installations.

IP66 enclosure with smart air cooling

IP66 ingress protection combined with intelligent air cooling allows outdoor installation without additional protective housing regardless of weather conditions - standard across the M1 lineup of the Sigen PV series (50-125 kW).

9 MPPT trackers in a single inverter

Nine independent MPPT trackers provide high flexibility for string configuration, which is useful for unconventional roof or ground layouts where modules face varying orientations and tilt angles.

High unit power rating up to 125 kW

Series models (50, 60, 80, 100, 110, 125 kW) with max DC voltage up to 1100 V allow fewer devices on site for the same installed capacity, reducing installation and AC/DC wiring costs.

Trade-offs
Young manufacturer with limited track record

Sigenergy was founded in 2022, meaning a shorter field-operation history compared to established tier-1 competitors like Huawei, Sungrow, or SMA. For commercial projects evaluated over a 20-25 year horizon, the lack of long-term reliability data can be a meaningful risk factor in bankability assessments.

Standard warranty capped at 10 years, extension sold separately

The base warranty for PV series models (e.g., 50 kW, 99.9 kW, 125 kW) is 10 years, with extension to 20 years requiring a separately purchased warranty package. Some tier-1 competitors in the C&I segment offer a longer standard warranty without an extra fee.

Inverter Power Euro eff. MPPT Weight Difference
Sigenergy 166M1 166.6 kW 98.4% 9 100.0 kg You are here
PVS-166-TL US 166.5 kW - 12 153.0 kg +3 MPPT, 53.0 kg heavier
XGI 1500-166/166-UL 166 kW - 1 122.0 kg -0.6 kW, -8 MPPT, 22.0 kg heavier
165 TL3 165 kW 99.0% 1 78.2 kg -1.6 kW, +0.6 pp efficiency, -8 MPPT
STT-165KTL-SE-HV 165 kW 98.3% 10 92.0 kg -1.6 kW, +1 MPPT, 8.0 kg lighter
SHP 165-US-21 165 kW - 1 99.0 kg -1.6 kW, -8 MPPT, 1.0 kg lighter
STT-170KTL-SE-HV 170 kW 98.3% 10 92.0 kg +3.4 kW, +1 MPPT, 8.0 kg lighter
Sunny Highpower PEAK3 SHP 172-21 172 kW 98.9% 1 99.0 kg +5.4 kW, +0.5 pp efficiency, -8 MPPT
Sunny Highpower Storage SHPS 172-21 172 kW 98.9% - 99.0 kg +5.4 kW, +0.5 pp efficiency, 1.0 kg lighter

About the Sigen PV series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How many Sigen PV inverters can be connected in parallel in a single installation?
The built-in EMS allows up to 100 Sigen PV units to be connected in parallel without an external data logger. This is a major advantage for large-scale PV farms, since installers don't need to purchase and configure a separate data acquisition device for multiple inverters, which speeds up design and commissioning of large commercial or industrial installations.
Can Sigen PV inverters be installed outdoors without a canopy or protective enclosure?
Yes, the enclosure carries an IP66 ingress protection rating, and intelligent air cooling is managed internally, allowing Sigen PV inverters to be mounted outdoors without additional shelter. They perform reliably in a range of weather conditions, including high humidity and dust, which are common at large PV farms on open ground or industrial rooftops.
How does the arc fault circuit interrupter (AFCI) in Sigen PV inverters work and what is its range?
The AFCI in the Sigen PV series detects electric arcing along cable runs up to 500 meters, which matters for extensive PV strings in large commercial installations. The system reacts automatically to detected hazards, improving fire safety, especially where DC wiring runs long distances between the panels and the inverter.
How many MPPT trackers does the Sigen PV series have, and is it suitable for unusual roof layouts?
The Sigen PV series features nine independent MPPT trackers, allowing flexible string configuration for unusual surfaces such as roofs with obstructions, varying tilt angles, or partial shading. This lets designers optimize each group of panels independently instead of compromising by combining them into a single lower-performing string.
Which installations benefit most from choosing a Sigen PV inverter instead of several smaller units?
The high rated power of the Sigen PV series allows a large installation to be served with fewer devices, reducing installation materials, wiring, and site space compared to using many smaller inverters. The built-in EMS and the ability to parallel up to 100 units also lower maintenance costs over the operational lifetime of a PV farm.
Do Sigen PV inverters require an external data logger to monitor performance?
No, thanks to the built-in energy management system (EMS), Sigen PV inverters do not require an additional data logger even when operating up to 100 units in parallel. This reduces extra hardware and potential points of failure, which matters for large installations where monitoring needs to remain stable and simple to maintain.