Skip to main content

Senergy SE 4K6TL-D1/G3

4.6 kW Grid-tie Single-phase
Datasheet PDF
Rated AC (kW)
4.60
Typical for its class
Euro eff. (%)
97.4
Typical · median 97.1%
MPPT
2
Typical · median 2
Max DC (V)
550
Typical · median 600 V
Weight (kg)
7.2
Strong · 11.3 kg below median
Warranty (yrs)
5
Typical · median 5 yrs

The Senergy SE KTL-D1/G3 series consists of single-phase inverters built for residential installations, where both performance and everyday ease of use matter. The units feature dual MPPT trackers, allowing independent optimization of two PV strings, even under uneven sunlight or partial roof shading. A wide input voltage range makes the inverter compatible with large, modern PV modules and various grid configurations, simplifying component selection for installers. Thanks to its IP66 protection rating and fanless natural cooling, the device can be mounted outdoors in demanding weather conditions without risk of dust or moisture entering the enclosure. The transformerless topology results in a compact footprint, low weight, and high energy conversion efficiency. The series also offers an optional AFCI 2.0 function for arc-fault detection, boosting system safety, along with remote management via a mobile app that enables quick commissioning, consumption monitoring, and remote firmware upgrades. It's a solid choice for installers seeking an inverter that combines reliability, configuration flexibility, and modern diagnostic tools in one compact unit.

Ranking

1,295 inverters from 3 to 6 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.4% 97.1% Typical 291
MPPT trackers 2 2 Typical 73
Max DC input voltage 550 V 600 V Typical 739
Weight per kW 1.6 4.0 Strong · top 3% 42
Warranty 5 yrs 5 yrs Typical 145
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 4.6 kW Continuous output
Max apparent power 5.06 kVA
Phases Single-phase
Nominal AC voltage 230 V 160-300V (Adjustable)
Max AC current 23.0 A
Grid frequency 50 Hz Range 45-55Hz/55-65Hz (Adjustable)
Power factor 0.8 leading - 0.8 lagging (Adjustable)
Harmonic distortion (THD) 3.0 %
Max DC input power 6.90 kW DC/AC ratio 1.50
Max DC voltage 550 V Caps the string length
MPPT voltage range 40 to 540 V
Start-up voltage 50 V
MPPT trackers 2 1 string each
Max input current per MPPT 20.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 30.0 A Must exceed the panel's Isc
European efficiency 97.4 % Weighted across part loads
Max efficiency 98.2 % Best single operating point
Dimensions 282 × 297 × 145 mm Height × width × depth
Weight 7.2 kg 1.6 kg per kW
Enclosure IP66
Cooling natural
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485Wi-Fi4GLAN
Protection AFCIDC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications IEC 62109-1IEC 62109-2IEC 61727IEC 62116IEC 60068IEC 61683VDE 4105PORTARIA n°140PORTARIA n°515

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT tracker

Two independent MPPT trackers allow separate optimization of two PV strings, which matters in practice for uneven irradiance, partial roof shading, or mismatched string orientation - a common scenario in residential installations with irregular roof geometry.

Transformerless topology

The absence of a low-frequency transformer results in lower weight and a more compact footprint, along with higher DC/AC conversion efficiency compared to older transformer-based single-phase inverter designs in this class.

IP66 enclosure with fanless cooling

IP66 ingress protection allows outdoor mounting without risk of dust or moisture penetration, while natural convective cooling eliminates a moving part (fan) that is typically a source of failures and noise in facade-mounted inverters.

Wide DC input voltage range

A wide input voltage window improves compatibility with modern, high-power PV modules (e.g., half-cut, bifacial) and various string configurations, simplifying system design for installers without requiring dedicated module selection.

AFCI 2.0 and mobile app management

The optional arc-fault detection feature (AFCI 2.0) improves fire safety for the installation, and the mobile app with energy consumption monitoring and remote firmware updates simplifies servicing without an on-site technician visit.

Trade-offs
Single-phase design only

The SE KTL-D1/G3 series is available only in a single-phase variant, limiting its use to smaller residential installations and forcing a switch to a different series (e.g., the three-phase DL3/T3) for higher installed capacity or three-phase grid connections.

AFCI 2.0 offered as an option, not standard

Arc-fault detection is marked as optional, meaning the base unit does not guarantee this protection out of the box - in some markets with NEC-like requirements, this may require additional configuration or cost compared to competitors offering AFCI as a standard feature.

Alternatives

All Senergy inverters
Inverter Power Euro eff. MPPT Weight Difference
Senergy SE 4K6TL-D1/G3 4.6 kW 97.4% 2 7.2 kg You are here
HYX-S4K6-S1 4.6 kW 97.6% - 11.6 kg 4.4 kg heavier
HYX-S4K6-S 4.6 kW 97.6% 2 11.6 kg 4.4 kg heavier
MIN 4600TL-X2 (Pro) 4.6 kW 97.5% 2 10.8 kg 3.6 kg heavier
4600P 4.6 kW 97.5% - 19.0 kg 11.8 kg heavier
HPS-4600P 4.6 kW 97.5% 2 8.2 kg Similar on paper
GW4600-SS 4.6 kW 97.4% 1 18.0 kg -1 MPPT, 10.8 kg heavier
XG4.6KTL 4.6 kW 97.4% 2 13.0 kg 5.8 kg heavier
SE 4K6TL-S1/G3 4.6 kW 97.4% 1 7.0 kg -1 MPPT

About the SE KTL-D1/G3 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the dual MPPT tracker in the Senergy SE KTL-D1/G3 differ from single-MPPT inverters?
Two independent MPPT trackers let you connect two separate PV strings and optimize each one independently. This keeps the system efficient even when one roof section is partially shaded or has a different orientation than the other. With a single-MPPT inverter, shading on one string drags down the whole array's output, whereas here the second tracker keeps working unaffected.
Can the Senergy SE KTL-D1/G3 inverter be installed outdoors?
Yes, the unit has an IP66 protection rating, meaning full protection against dust and powerful water jets, making it suitable for outdoor mounting, for example on a house facade. It also uses natural cooling without a fan, so there are no moving parts that could get clogged or fail in harsh weather conditions.
What is AFCI 2.0 on the SE KTL-D1/G3 inverter and is it worth having?
AFCI 2.0 is an optional arc-fault detection function on the DC side, identifying dangerous arcing that can occur from damaged wiring. The inverter automatically detects the anomaly and disconnects the array, reducing fire risk. This extra safety layer is especially valuable on wooden roof structures or with older wiring.
Can the Senergy SE KTL-D1/G3 inverter be managed remotely from a phone?
Yes, the series supports remote management via a mobile app, enabling quick setup during installation, real-time monitoring of energy production and consumption, and remote firmware updates. Installers or homeowners can check inverter status without physically approaching the device.
Is the transformerless SE KTL-D1/G3 inverter less durable than a transformer-based inverter?
The transformerless topology doesn't mean lower durability; it mainly delivers lower weight, a compact footprint, and higher conversion efficiency compared to transformer-based inverters. Skipping the transformer reduces energy losses during DC-to-AC conversion, and with proper system protection this has no negative impact on the unit's lifespan.
Which PV modules are compatible with the Senergy SE KTL-D1/G3 inverter?
A wide input voltage range allows connection of large, modern high-power PV modules across various string configurations, without needing a narrow, dedicated module lineup. This gives installers more flexibility in module selection and makes it easier to design a system tailored to a specific roof and budget.