Skip to main content
HYXiPower HYX-S4K6-S

HYXiPower HYX-S4K6-S

4.6 kW Grid-tie Single-phase
Datasheet PDF
Rated AC (kW)
4.60
Typical for its class
Euro eff. (%)
97.6
Strong · top 18%
MPPT
2
Typical · median 2
Max DC (V)
600
Typical · median 600 V
Weight (kg)
11.6
Strong · 6.4 kg below median
Warranty (yrs)
-
Not published

The HYX-S-S series comprises single-phase string inverters built for residential solar installations where both performance and ease of installation matter. The lineup stands out with an 18A input per MPPT, allowing seamless compatibility with today's high-power modules built on half-cut cells, without throttling their output potential. Thanks to 160% PV oversizing, installers gain significant flexibility when designing strings and can extend daily energy generation, effectively lowering the system's LCOE. Safety is reinforced by 300-meter AFCI arc-fault detection with a 0.5-second shutdown, paired with a rugged, weatherproof IP66 enclosure. The inverter also simplifies service and maintenance through intelligent IV diagnostics, which pinpoint faults down to the individual string level, along with real-time monitoring via a dedicated app. A compact, lightweight design and plug-and-play installation shorten setup time, making this series an appealing choice for installers who value reliability and investors looking for low operating costs in residential PV systems.

Ranking

1,005 inverters from 3 to 6 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.6% 97.1% Strong · top 18% 110
MPPT trackers 2 2 Typical 59
Max DC input voltage 600 V 600 V Typical 261
Weight per kW 2.5 3.9 Strong · top 22% 218
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 4.6 kW Continuous output
Max apparent power 5.06 kVA
Phases Single-phase
Nominal AC voltage 230 V
Max AC current 23.0 A
Grid frequency 60 Hz
Power factor 0.8 leading...0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 7.36 kW DC/AC ratio 1.60
Max DC voltage 600 V Caps the string length
MPPT voltage range 80 to 560 V
Start-up voltage 100 V
MPPT trackers 2 1 string each
Max input current per MPPT 18.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 24.0 A Must exceed the panel's Isc
European efficiency 97.6 % Weighted across part loads
Max efficiency 98.2 % Best single operating point
Dimensions 360 × 340 × 136 mm Height × width × depth
Weight 11.6 kg 2.5 kg per kW
Enclosure IP66
Cooling natural
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS4854GWi-Fi
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
High-current 18A MPPT tracker

Each MPPT tracker accepts up to 18A, allowing connection of high-power half-cut modules without current clipping. This exceeds the typical 13-16A found in competing string inverters of comparable power class.

160% PV oversizing ratio

A DC/AC ratio of up to 160% gives installers significant flexibility in string design and extends daily energy generation window, materially shortening payback time in residential PV installations.

AFCI with 300m range and 0.5s trip time

Arc-fault detection with a 300-meter range and automatic shutdown within 0.5 seconds matches safety performance seen in leading residential inverter solutions.

Smart IV diagnostics at string level

Built-in IV curve diagnostics pinpoint faults at the individual string level without physical inspection, reducing service time and lowering operating costs for installers.

IP66 enclosure and plug-and-play install

IP66-rated dust and water-jet resistance allows outdoor mounting without extra shielding, while the compact, lightweight plug-and-play design shortens installation time compared to conventional string inverters.

Trade-offs
Limited series power range

The HYX-S-S series spans roughly 2-6 kW, restricting its application to small and mid-size residential installations. Larger prosumer systems require other series from the manufacturer or competing three-phase solutions.

Shorter brand track record in Europe

HYXiPower has a notably shorter presence on European markets compared to established Tier-1 brands (e.g., Huawei, SMA, Fronius), meaning less long-term field reliability data and a potentially less developed local service network.

Inverter Power Euro eff. MPPT Weight Difference
HYXiPower HYX-S4K6-S 4.6 kW 97.6% 2 11.6 kg You are here
HYX-S4K6-S1 4.6 kW 97.6% - 11.6 kg Similar on paper
MIN 4600TL-X2 (Pro) 4.6 kW 97.5% 2 10.8 kg Similar on paper
4600P 4.6 kW 97.5% - 19.0 kg 7.4 kg heavier
GW4600-SS 4.6 kW 97.4% 1 18.0 kg -1 MPPT, 6.4 kg heavier
XG4.6KTL 4.6 kW 97.4% 2 13.0 kg 1.4 kg heavier
XG4.6KTL-S 4.6 kW 97.3% 1 6.0 kg -1 MPPT, 5.6 kg lighter
STS-4.6KTL-SE 4.6 kW 97.3% 2 11.5 kg Similar on paper
MIN 4600TL-X 4.6 kW 97.1% 2 10.8 kg -0.5 pp efficiency

About the HYX-S-S series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What module power rating works best with the HYX-S-S series inverters?
Thanks to 160% PV oversizing on the DC side, HYX-S-S inverters pair well with high-power modules, including half-cut panels above 500 W. This oversizing lets installers connect more module power than the inverter's AC rating, extending daily energy generation and improving system payback, especially on roofs with limited surface area.
Can the HYX-S-S inverter handle half-cut cell modules without derating their output?
Yes. The inverter supports 18A per MPPT tracker, a higher rating than many competing models, allowing safe connection of half-cut modules with high current output without limiting their potential. This means installers don't need to downgrade panel selection or split strings into smaller groups just to stay within input current limits.
What is arc fault detection (AFCI) in the HYX-S-S and does it improve installation safety?
AFCI detects sparking and arc faults in the DC circuit, which can occur from damaged connectors or worn cabling. The HYX-S-S monitors a 300-meter radius and shuts down within 0.5 seconds upon detecting a fault. This significantly reduces fire risk in residential installations, particularly on roofs covered with flammable materials.
Can the HYX-S-S inverter be installed outdoors and how does it handle moisture?
Yes, the enclosure has an IP66 rating, meaning full dust protection and resistance to powerful water jets from any direction. The inverter can be safely mounted on an exterior wall, garage, or facade exposed to rain, without needing an additional protective canopy.
How can I identify which PV string has a fault in a system using the HYX-S-S inverter?
The inverter uses smart IV diagnostics, analyzing the current-voltage curve of each connected string and comparing it to expected values. This lets a technician remotely pinpoint a string with a damaged panel, a bad connection, or shading issues without climbing onto the roof, substantially cutting diagnosis time and service cost.
Is the HYX-S-S inverter difficult for installers to mount?
No, the series is built as plug and play, with a lightweight, compact housing that doesn't require extra help to lift or secure. DC and AC connectors are ready for quick hookup, and initial configuration is done via a mobile app, which shortens installation and commissioning time for a typical single-family home to a single working day.