The CHS2 series is a complete, integrated energy storage system for commercial and industrial applications, combining a hybrid inverter, LiFePO4 batteries, and a control cabinet in a single, factory-assembled enclosure. This design eliminates tedious on-site assembly and configuration - the unit arrives essentially ready to commission, shortening deployment time and reducing the risk of installation errors. Thanks to DC coupling of the PV array with the energy storage and support for 200% PV oversizing across six MPPT trackers, the CHS2 system makes the most of available roof or ground space and boosts energy yield even with a limited grid connection. The series stands out with a robust safety package: integrated AFCI protection against arc-fault fires, class II AC and DC surge protection, plus battery cell health monitoring, carbon monoxide detection, and cabinet-level fire protection. CHS2 can run alongside a diesel generator without extra equipment, supports AC coupling, and thanks to intelligent scheduling modes and a wide operating temperature range, it performs well both for UPS-style backup switching and for energy arbitrage strategies or participation in virtual power plant (VPP) services. It's a solution built for businesses and installers looking for a ready-made, scalable storage system rather than piecing together separate components.
Ranking
Specifications
Pros and cons
CHS2 combines a hybrid inverter, LiFePO4 batteries and a control cabinet in one factory-prepared enclosure, eliminating on-site assembly of separate components and shortening deployment time for C&I installations compared to systems built from discrete parts.
The system supports DC coupling of PV with the energy storage and up to 200% PV oversizing across six MPPT trackers, maximizing roof or ground utilization and output even with limited grid connection capacity - confirmed in the manufacturer's global datasheet.
Integrated AFCI for arc-fault fire protection, Class II AC and DC surge protection, battery cell monitoring, and carbon monoxide and fire detection at the cabinet level - standard equipment confirmed in SAJ's EU and AU documentation, which is uncommon at this price point for C&I storage systems.
CHS2 supports generator input and AC coupling without additional components, with grid/off-grid switching within 20 ms, making the system flexible for UPS backup roles, energy arbitrage, and virtual power plant (VPP) grid-service participation.
The system architecture supports up to 4 battery clusters running in parallel per cabinet (cluster capacity from 57.3 to 186.2 kWh per datasheets), and units can be paralleled for larger installations, simplifying capacity expansion without changing the system architecture.
CHS2 relies on air cooling rather than liquid cooling, which larger C&I ESS competitors use for better thermal stability at high ambient temperatures and high charge currents - this may limit battery longevity in hot climates under sustained full load.
In the commercial and industrial storage segment, SAJ has a smaller market share and service network than tier-1 global leaders in this category (e.g., Huawei, Sungrow), which can mean longer service response times or limited spare-parts availability in regions outside China and Europe.