Skip to main content

SAJ CH2-29.9K-T4

30 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
30.00
Strong · top 15%
Euro eff. (%)
97.3
Weak · bottom 20%
MPPT
-
Not published
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
76.0
Typical · median 38.0 kg
Warranty (yrs)
10
Strong · top 18%

The CHS2 series is a complete, integrated energy storage system for commercial and industrial applications, combining a hybrid inverter, LiFePO4 batteries, and a control cabinet in a single, factory-assembled enclosure. This design eliminates tedious on-site assembly and configuration - the unit arrives essentially ready to commission, shortening deployment time and reducing the risk of installation errors. Thanks to DC coupling of the PV array with the energy storage and support for 200% PV oversizing across six MPPT trackers, the CHS2 system makes the most of available roof or ground space and boosts energy yield even with a limited grid connection. The series stands out with a robust safety package: integrated AFCI protection against arc-fault fires, class II AC and DC surge protection, plus battery cell health monitoring, carbon monoxide detection, and cabinet-level fire protection. CHS2 can run alongside a diesel generator without extra equipment, supports AC coupling, and thanks to intelligent scheduling modes and a wide operating temperature range, it performs well both for UPS-style backup switching and for energy arbitrage strategies or participation in virtual power plant (VPP) services. It's a solution built for businesses and installers looking for a ready-made, scalable storage system rather than piecing together separate components.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.3% 98.0% Weak · bottom 20% 367
MPPT trackers - 2 Not published -
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 2.5 1.8 Typical 429
Warranty 10 yrs 5 yrs Strong · top 18% 8
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 30 kW Continuous output
Max apparent power 30.00 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 43.3 A
Grid frequency 50 Hz Range 45-55
Power factor 0i - 1 - 0c
Harmonic distortion (THD) 3.0 %
Max DC input power 60.00 kW DC/AC ratio 2.00
Max DC voltage 1000 V Caps the string length
MPPT voltage range 180 to 850 V
Start-up voltage 200 V
Max input current per MPPT 45.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 56.5 A Must exceed the panel's Isc
European efficiency 97.3 % Weighted across part loads
Max efficiency 98.0 % Best single operating point
Battery port Yes
Battery voltage 180-800
Max charge current 150.0 A
Max discharge current 150.0 A
Dimensions 630 × 630 × 290 mm Height × width × depth
Weight 76.0 kg 2.5 kg per kW
Enclosure IP55, IP66(Inverter)
Cooling Air Conditioner
Operating temperature -30 to 50 °C
Max humidity 95 %
Max altitude 2000 m
Interfaces Wi-FiEthernet
Protocols RS485EthernetWi-Fi
Protection AFCIDC switchSurge protection
Warranty 10 years Standard manufacturer cover
Certifications VDE4105IEC61727/62116VDE0126AS4777.2CEI 0 21EN50549-1G98G99C10-11UNE217002NBR16149/NBR16150IEC62109-1/-2NBT32004-2018EN61000-6-1EN61000-6-2EN61000-6-3EN61000-6-4

Pros and cons

5 positive · 2 caution
What owners get
Factory-integrated all-in-one system

CHS2 combines a hybrid inverter, LiFePO4 batteries and a control cabinet in one factory-prepared enclosure, eliminating on-site assembly of separate components and shortening deployment time for C&I installations compared to systems built from discrete parts.

200% PV oversizing across 6 MPPT trackers

The system supports DC coupling of PV with the energy storage and up to 200% PV oversizing across six MPPT trackers, maximizing roof or ground utilization and output even with limited grid connection capacity - confirmed in the manufacturer's global datasheet.

Extensive safety package

Integrated AFCI for arc-fault fire protection, Class II AC and DC surge protection, battery cell monitoring, and carbon monoxide and fire detection at the cabinet level - standard equipment confirmed in SAJ's EU and AU documentation, which is uncommon at this price point for C&I storage systems.

Generator operation and AC coupling without extra hardware

CHS2 supports generator input and AC coupling without additional components, with grid/off-grid switching within 20 ms, making the system flexible for UPS backup roles, energy arbitrage, and virtual power plant (VPP) grid-service participation.

Modular storage scalability

The system architecture supports up to 4 battery clusters running in parallel per cabinet (cluster capacity from 57.3 to 186.2 kWh per datasheets), and units can be paralleled for larger installations, simplifying capacity expansion without changing the system architecture.

Trade-offs
Air-cooled design, no liquid-cooling option

CHS2 relies on air cooling rather than liquid cooling, which larger C&I ESS competitors use for better thermal stability at high ambient temperatures and high charge currents - this may limit battery longevity in hot climates under sustained full load.

Smaller brand footprint in the C&I ESS segment

In the commercial and industrial storage segment, SAJ has a smaller market share and service network than tier-1 global leaders in this category (e.g., Huawei, Sungrow), which can mean longer service response times or limited spare-parts availability in regions outside China and Europe.

Alternatives

All SAJ inverters
Inverter Power Euro eff. MPPT Weight Difference
SAJ CH2-29.9K-T4 30 kW 97.3% - 76.0 kg You are here
HYX-H29K9-HSA2 30 kW 98.2% - 38.0 kg +0.9 pp efficiency, 38.0 kg lighter
H2-30K-T3-DE 30 kW 97.6% 3 50.0 kg 26.0 kg lighter
CHS2-29.9K-T4-X 30 kW 97.3% - - Similar on paper
HYX-H30K-HSA2 30 kW 98.2% - 38.0 kg +0.9 pp efficiency, 38.0 kg lighter
AF30K-TH 30 kW 98.1% 2 36.0 kg +0.8 pp efficiency, 40.0 kg lighter
SUN-30K-SG02HP3-EU-AM3 30 kW 98.0% 3 46.0 kg +0.7 pp efficiency, 30.0 kg lighter
SigenStor EC 30.0 TP 30 kW 98.0% - 36.0 kg +0.7 pp efficiency, 40.0 kg lighter
Sigen Hybrid 30.0 TP 30 kW 98.0% - 36.0 kg +0.7 pp efficiency, 40.0 kg lighter

About the CHS2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the CHS2 system differ from a traditional setup with separately installed inverter and batteries?
CHS2 is a fully integrated system - the hybrid inverter, LiFePO4 batteries, and control cabinet come pre-assembled in a single factory-built enclosure. This eliminates time-consuming on-site assembly and configuration of separate components, shortening deployment time and reducing the risk of installation errors. Instead of combining individual parts, installers receive a ready-made unit that only needs to be connected and commissioned on site.
How many PV panels can be connected to the CHS2 system, and what does 200% oversizing mean?
CHS2 supports six MPPT inputs and allows PV oversizing of up to 200% relative to the inverter's rated power. This means that even with a limited grid connection capacity, installers can fit double the panel capacity, making maximum use of available roof or ground space and boosting total energy production, especially during periods of lower irradiance.
What fire safety protections does the CHS2 series include?
The CHS2 system features integrated AFCI protection against arc-fault fires, Type II surge protection on both AC and DC sides, and continuous battery cell monitoring. The cabinet also includes carbon monoxide and fire detection sensors, which matters for commercial and industrial installations where system safety is critical.
Can the CHS2 work with a backup generator during power outages?
Yes, CHS2 supports generator operation without requiring additional hardware, and it also supports AC coupling. This allows the system to switch between grid, energy storage, and generator power, making it well suited for commercial and industrial sites that need uninterrupted power, such as in UPS-style backup applications.
What business use cases does CHS2 support beyond emergency backup power?
Thanks to intelligent work scheduling and a wide operating temperature range, CHS2 is used for UPS-style emergency switching, but also for energy arbitrage strategies - charging batteries during low-price hours and discharging during peak hours - as well as participation in virtual power plant (VPP) grid services, letting businesses generate extra revenue from their energy storage asset.
What efficiency and energy capacity does the CHS2 system offer?
The CHS2 system uses LiFePO4 battery cells, known for long cycle life and strong thermal stability, which matters for industrial applications with heavy cyclic loads. Available power and capacity configurations vary by model, so exact efficiency and energy capacity figures should always be confirmed in the datasheet of the specific CHS2 variant selected for a given project.