The blueplanet gridsave GEN2 series is the second generation of KACO's industrial battery inverters, built for commercial and industrial energy storage installations. The key upgrade over the previous generation is an extended DC voltage window up to 1450 V, giving system designers greater flexibility in battery configuration while reducing losses on the DC side. These units operate as a bidirectional battery inverter handling both charging and discharging in grid-following mode, making them a natural fit for peak shaving, grid balancing, and integration with photovoltaic systems. Digital security has been strengthened through enhanced cybersecurity for the Modbus TCP/Sunspec-based communication, which matters when managing a fleet of storage assets remotely. The transformerless design and IP66-rated enclosure allow outdoor installation in demanding environments, while three hardware variants, M, L, and XL, differentiate the DC protection scope (fuse, contactor, pre-charge circuit) to match project requirements. The series also follows a future-proof certification roadmap aligned with evolving grid codes, helping investors plan long-term deployments without the risk of the hardware becoming quickly outdated.
Ranking
Specifications
Pros and cons
GEN2 raises the maximum DC voltage to 1,450 V (versus roughly 1,315 V on the prior TL3-S generation), enabling longer battery strings, lower conduction losses, and simpler configuration for commercial/industrial storage systems.
SiC-based power electronics push maximum efficiency to 98.9%, a clear improvement over GEN1 (around 98.5-98.7% on the 92-137 kW models), translating into lower round-trip energy losses.
The inverter handles simultaneous charging and discharging in real time, making it directly applicable to peak shaving, energy arbitrage, and grid balancing without additional management hardware.
For remote battery storage fleet management, strengthened communication security reduces the risk of unauthorized access to operating parameters, which is increasingly relevant under tightening EU cybersecurity requirements (e.g., NIS2).
Differentiated DC protection levels (fuse, contactor, pre-charge circuit) across three variants let investors choose the protection level needed without paying for unused features in simpler projects.
Maximum output per unit in the 92-137 kVA class is significantly lower than utility-scale competitors such as Sungrow (e.g., SC2500UD-MV at ~2.5 MVA per block), requiring multiple KACO units in parallel for large storage projects and increasing BoS complexity and cost.