Skip to main content

Ingeteam 3TL M

3 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
3.00
Strong · top 21%
Euro eff. (%)
95.1
Weak · bottom 3%
MPPT
2
Strong · top 22%
Max DC (V)
550
Typical · median 550 V
Weight (kg)
26.0
Weak · 15.2 kg above median
Warranty (yrs)
5
Typical · median 5 yrs

The INGECON SUN STORAGE 1Play TL M series consists of single-phase hybrid inverters built for PV+battery systems, eliminating the need for a separate photovoltaic inverter. The series stands out with its dual MPPT system, which makes it possible to draw maximum power from roof arrays with different panel orientations or partial shading, a common challenge in typical residential installations. At the core of the unit is a built-in EMS (Energy Management System), which intelligently manages energy flows between the panels, battery, and grid, including scheduling of battery charge and discharge times. The series offers flexible operating modes: self-consumption with the option to add storage at a later stage, stand-alone operation with support for a backup generator, and UPS mode with an almost instantaneous switch to backup power, making it an appealing choice for households with unstable grid supply. Additional strengths include a peak shaving functionality that reduces peak loads and EV charger integration via Modbus TCP and Wi-Fi communication. The IP65-rated enclosure allows both indoor and outdoor mounting, a feature installers will appreciate when looking for a versatile solution for single-family homes and small commercial installations.

Ranking

449 inverters up to 3 kW
Metric This inverter Median Position in class Rank in class
European efficiency 95.1% 96.9% Weak · bottom 3% 266
MPPT trackers 2 1 Strong · top 22% 6
Max DC input voltage 550 V 550 V Typical 125
Weight per kW 8.7 5.5 Weak · bottom 18% 362
Warranty 5 yrs 5 yrs Typical 29
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 3 kW Continuous output
Phases Single-phase
Nominal AC voltage 230 V 172-264V
Max AC current 13.0 A
Grid frequency 50 Hz Range 40-70Hz
Power factor 0 ~ 1
Max DC input power 11.50 kW DC/AC ratio 3.83
Max DC voltage 550 V Caps the string length
MPPT voltage range 80 to 480 V
MPPT trackers 2 1 string each
Max input current per MPPT 15.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 20.0 A Must exceed the panel's Isc
European efficiency 95.1 % Weighted across part loads
Max efficiency 95.5 % Best single operating point
Battery port Yes
Battery voltage 40-460V
Max charge current 66.0 A
Max discharge current 66.0 A
Grid-forming Yes
Dimensions 470 × 360 × 180 mm Height × width × depth
Weight 26.0 kg 8.7 kg per kW
Enclosure IP65
Cooling forced-air
Operating temperature -20 to 65 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS-485Wi-FiEthernetCAN Bus 2.0Modbus TCP
Protection DC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications CEEN 61000-6-1EN 61000-6-2EN 61000-6-3EN 61000-6-4EN 61000-3-11EN 61000-3-12EN 62109-1EN62109-2AS62040.1FCC Part 15DIN V VDE V 0126-1-1EN 50438CEI 0-21VDE-AR-N4105:2011-08G59/3G83/2AS4777.2:2015IEC 62116UNE 206007-1:2013UNE 206006:2011UNE 217001 IN:2015NRS097-2-1ABNT NBR 16149ABNT NBR 16150P.O.12.2G99EN 50549-1

Pros and cons

5 positive · 3 caution
What owners get
Dual MPPT for mixed-orientation roofs

Two independent MPPT trackers efficiently handle panels with different orientations or partial shading, a common issue in residential installations and less often found in competing single-phase hybrids of this power class.

Built-in EMS, no extra controller needed

The integrated energy management system coordinates PV-battery-grid flows and schedules charge/discharge cycles, removing the need for an external energy controller and lowering BoS costs.

UPS mode with instant switchover

Automatic switch to battery backup power makes the unit attractive for customers on unstable grids, while the additional off-grid mode with generator support extends use cases beyond typical on-grid systems.

Peak shaving and EV charger integration

Peak load shaving plus Modbus TCP/Wi-Fi communication with EV chargers let the inverter act as part of a broader home energy ecosystem, a feature not standard at this price point.

Broad battery compatibility

Confirmed support for Pylontech US2000/US3000/FORCE-L1/FORCE-L2, LG Chem RESU, and BYD LVS gives installers flexibility in battery storage choice without being locked to a single manufacturer.

Trade-offs
Short standard warranty (5 years)

The manufacturer offers a 5-year base warranty with paid extensions up to 15-20 years, whereas some tier-1 hybrid competitors (e.g., Huawei, SolarEdge) include 10-12 years as standard at no extra cost.

Mixed feedback on warranty service

Available user reviews (e.g., a 2.8/5 rating on SolarQuotes) cite isolated cases of unresolved warranty claims, and with few independent long-term tests, it's hard to fully assess after-sales support quality.

Limited list of compatible storage units

Despite supporting several battery brands (Pylontech, LG Chem, BYD), the list is closed and requires verification against current manufacturer documentation - there's no open communication standard, unlike inverters supporting a wider range of CAN/RS485 protocols.

Alternatives

All Ingeteam inverters
Inverter Power Euro eff. MPPT Weight Difference
Ingeteam 3TL M 3 kW 95.1% 2 26.0 kg You are here
SE3000H 3 kW 98.8% - 12.0 kg +3.7 pp efficiency, 14.0 kg lighter
HYX-H3K-HSA2 3 kW 98.2% - 38.0 kg +3.1 pp efficiency, 12.0 kg heavier
Sigen Hybrid 3.0 SP2 3 kW 98.0% 2 11.5 kg +2.9 pp efficiency, 14.5 kg lighter
MOD 3000TL3-HU 3 kW 97.8% 2 19.0 kg +2.7 pp efficiency, 7.0 kg lighter
SPM 3000TL-HU 3 kW 97.6% 2 26.0 kg +2.5 pp efficiency
SUN2000L-3KTL 3 kW 97.6% 2 10.6 kg +2.5 pp efficiency, 15.4 kg lighter
MOD 3000TL3-XH 3 kW 97.5% 2 12.5 kg +2.4 pp efficiency, 13.5 kg lighter
AF3K-MTH 3 kW 97.5% 2 22.0 kg +2.4 pp efficiency, 4.0 kg lighter

About the SUN STORAGE 1Play TL M series

7 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Does the INGECON SUN STORAGE 1Play TL M require a separate PV inverter?
No. The 1Play TL M is a hybrid unit that combines a PV inverter and a battery storage inverter in a single enclosure. Its dual MPPT handles solar panel input directly, while the built-in EMS manages battery charging and discharging simultaneously. This lets installers deploy one device instead of two, reducing both installation time and BoS costs compared to AC-coupled retrofit setups.
Which battery storage systems are compatible with the 1Play TL M series?
The inverter supports a battery DC voltage range of roughly 40 to 460 V and a maximum charge/discharge current of up to 66 A, allowing it to work with both lead-acid batteries and popular lithium-ion systems such as Pylontech, BYD, or LG. Communication runs over CAN or RS485, so it is worth checking the manufacturer's current compatibility list for your specific battery model before purchasing.
How does the UPS mode work and how fast does it switch to backup power?
UPS mode automatically switches the home to battery backup almost instantly after a grid outage is detected, with an interruption short enough to be unnoticeable for most household devices. This feature is especially useful in areas with frequent grid instability, since it allows selected circuits to keep running off-grid as long as the battery holds enough charge.
Can the 1Play TL M inverter be installed outdoors?
Yes, the enclosure carries an IP65 rating, meaning it is fully dust-tight and protected against water jets, so it can be safely mounted either inside a garage or utility room or directly on an exterior wall. This gives installers more flexibility in choosing the mounting location, especially in single-family homes with limited indoor technical space.
What does the peak shaving function do, and is it actually useful?
Peak shaving automatically supplements the grid with battery power during periods of high demand, for example when a heat pump, water heater, and EV charger run at the same time. This helps limit the peak power drawn from the grid, which matters for contracts with a power demand limit or for avoiding a costly upgrade of the electrical connection.
Can an EV charger be connected to the 1Play TL M inverter?
Yes, the series supports EV charger integration via Modbus TCP or Wi-Fi, enabling smart charging management based on energy currently available from the solar panels or the battery. In practice, this lets the system prioritize charging the vehicle with excess solar power instead of relying on more expensive grid electricity.
Does the 1Play TL M need an additional bidirectional meter when operating with a battery?
The built-in EMS independently manages energy flows between the panels, battery, and grid, but a dedicated energy sensor, supplied or specified by the manufacturer, is typically installed for precise household energy balance measurement. This allows the system to dynamically schedule battery charging and discharging based on actual home consumption patterns.