Skip to main content

FIMER UNO-DM-6.0-TL-PLUS-US-Q

6 kW Grid-tie Single-phase
Datasheet PDF
Rated AC (kW)
6.00
Strong · top 12%
Euro eff. (%)
-
Not published
MPPT
2
Typical · median 2
Max DC (V)
600
Typical · median 600 V
Weight (kg)
21.5
Typical · median 18.0 kg
Warranty (yrs)
-
Not published

The FIMER UNO-DM-PLUS series is a family of compact single-phase inverters built for residential installations and small commercial systems, where fast mounting and minimal footprint matter most. All power ratings in the family share nearly identical, lightweight enclosures, making it easy for installers to standardize their workflow across different projects. The inverter features two independent MPPT channels, allowing flexible combination of strings with different tilt angles or shading conditions to maximize real-world energy yield. Built-in WLAN connectivity plus free lifetime access to the Aurora Vision monitoring platform remove the need for extra accessories for remote system oversight. An additional load-control output helps boost self-consumption of generated energy, a key advantage as electricity prices rise and net-metering rules continue to shift. A version with an integrated DC disconnect switch is also available, cutting installation time and the number of components needed on site. Compliance with multiple national grid codes makes this series a versatile choice for installers working across various European markets, who are looking for a proven, compact, premium-class solution without unnecessary installation complexity.

Ranking

1,005 inverters from 3 to 6 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 97.1% Not published -
MPPT trackers 2 2 Typical 59
Max DC input voltage 600 V 600 V Typical 261
Weight per kW 3.6 3.9 Typical 429
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 6 kW Continuous output
Max apparent power 6.65 kVA
Phases Single-phase
Nominal AC voltage 240 V 211-264V
Max AC current 30.0 A
Grid frequency 60 Hz Range 50-64Hz
Power factor >0.995, adj. +/-0.8
Harmonic distortion (THD) 2.0 %
Max DC input power 8.00 kW DC/AC ratio 1.33
Max DC voltage 600 V Caps the string length
MPPT voltage range 200 to 580 V
Start-up voltage 200 V
MPPT trackers 2
Max input current per MPPT 20.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 24.0 A Must exceed the panel's Isc
Max efficiency 97.4 % Best single operating point
CEC efficiency 97.0 % California Energy Commission weighting
Dimensions 729 × 553 × 222 mm Height × width × depth
Weight 21.5 kg 3.6 kg per kW
Enclosure Type 4X
Cooling natural
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces Wi-FiEthernet
Protocols Wireless (WLAN IEEE 802.11 b/g/n)ModBus TCP (SunSpec)ModBus RTU (SunSpec)RS485EthernetAurora Protocol
Protection AFCIDC switchSurge protection
Certifications UL1741IEEE1547.1CSA-C22.2 N.107.1-01UL1998UL1699B-2018FCC Part 15 Class BUL 1741 SAIEEE 1547Rule 21Rule 14 (HI)CTUVUS

Pros and cons

5 positive · 2 caution
What owners get
Dual independent MPPT trackers

Two MPPT inputs (on 3.3-5.0/6.0 kW variants) allow connecting PV strings with different orientation, tilt, or shading, which in a typical pitched-roof installation delivers higher real-world yield than single-tracker designs in this class.

Built-in WLAN, no extra accessories needed

An integrated WLAN module and free access to the Aurora Vision monitoring platform remove the need for external loggers or paid communication cards, lowering BoS cost compared to competitors requiring paid monitoring subscriptions.

Compact, lightweight, unified housing

A nearly identical enclosure across the entire power range simplifies installation standardization and spare mounting hardware inventory for installers working on multiple projects.

Optional integrated DC disconnect

The version with a built-in DC disconnect switch reduces installation time and the number of components needed on site, which is especially valued in time-pressured residential installs.

Load control output

An additional load-management output (e.g., for a water heater) increases self-consumption of PV energy, which is increasingly relevant given changing prosumer billing schemes such as net-billing in Poland.

Trade-offs
Discontinued, limited service availability

Launched in 2016, the series has been discontinued; following FIMER's financial troubles (administration in 2023 and acquisition by MA Solar Italy in January 2025), spare parts and service support for older models are more limited than for current tier-1 manufacturer lineups.

Lacks modern communication interfaces

Unlike current premium-class inverters with native RS485/Modbus TCP or home energy management system integration, the UNO-DM-PLUS relies mainly on WLAN and an optional Ethernet module, limiting integration with newer HEMS platforms.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER UNO-DM-6.0-TL-PLUS-US-Q 6 kW - 2 21.5 kg You are here
SolarEdge SE6000H (HD‑Wave, single phase) 6 kW 99.0% - 10.6 kg 10.9 kg lighter
XG6KTR-S 6 kW 98.3% 2 12.0 kg 9.5 kg lighter
BNT006KTL 6 kW 98.0% 2 16.0 kg 5.5 kg lighter
StecaGrid 6013 6 kW 98.0% 1 12.0 kg -1 MPPT, 9.5 kg lighter
SPI6K-B 6 kW 98.0% 2 18.5 kg 3.0 kg lighter
STT-6KTL-P 6 kW 98.0% 2 23.0 kg 1.5 kg heavier
HNS6000TL 6 kW 97.9% 2 10.0 kg 11.5 kg lighter

About the UNO-DM-PLUS series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the FIMER UNO-DM-PLUS inverter still available for purchase?
The FIMER UNO-DM-PLUS series has been discontinued and is no longer offered as a new product through standard sales channels. Availability is now limited to remaining distributor stock or the secondary market. When choosing a replacement for an existing installation, it is worth consulting an installer about the compatibility of newer FIMER models with already installed panels and DC wiring.
How do the two MPPT trackers on the UNO-DM-PLUS differ, and when should they be used?
The two independent MPPT trackers let you connect two separate panel strings that operate independently of one another. This is useful when panels are mounted on two roof sections with different tilt angles or orientations, or when part of the array is partially shaded, for example by chimneys. As a result, each string reaches its own optimal operating point, increasing real energy yield compared to a single shared MPPT tracker.
Does the UNO-DM-PLUS require an additional module for remote internet monitoring?
No, the inverter has a built-in WLAN module and free access to the Aurora Vision monitoring platform, so there is no need to purchase external communication cards or data loggers. Simply connect the inverter to a home Wi-Fi network to track energy production, the status of both MPPT trackers, and any alarms in real time via the mobile app or browser, with no subscription fees.
Is the UNO-DM-PLUS version with an integrated DC disconnect safer and easier to install?
The version with an integrated DC disconnect lets you cut DC current from the panels directly at the inverter housing, eliminating the need for a separate disconnect box on the wall or in a switchboard. This shortens installation time, reduces the number of components on site, and simplifies maintenance, since the DC disconnection is performed in one easily accessible location in line with safety requirements.
Is the UNO-DM-PLUS series suited for residential or commercial installations?
The UNO-DM-PLUS is a compact single-phase inverter designed mainly for residential installations and small commercial systems, such as small offices or retail units. Its light weight and standardized housing across power ratings simplify mounting on a wall or in a garage, and the additional load control output helps increase self-consumption of solar energy in single-family homes.
Can the UNO-DM-PLUS be installed across different European countries in terms of grid codes?
Yes, the UNO-DM-PLUS complies with numerous national grid codes used across Europe, allowing installers to use a single model across multiple markets without choosing separate regional variants. This simplifies logistics for installation companies operating internationally, though it is always worth verifying the current requirements of the local grid operator before installation.