Skip to main content

FIMER PVS-60-TL

60 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
60.00
Typical for its class
Euro eff. (%)
98.4
Strong · top 15%
MPPT
3
Weak · bottom 17%
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
70.0
Typical · median 75.0 kg
Warranty (yrs)
-
Not published

The FIMER PVS-TL series comprises three-phase string inverters built for commercial and industrial installations, where both mounting flexibility and reliable operation under heavy rooftop and facility loads matter most. The compact, lightweight design allows for fast installation even in hard-to-reach locations, without the need for additional lifting equipment. These units stand out with single string current monitoring, enabling immediate diagnostics at the individual module string level and shortening service response times. The optional integrated arc fault circuit interrupter (AFCI) boosts fire safety for the installation, which is especially important in large-area commercial facilities. The built-in export power limitation function allows the system's output to be matched to grid operator requirements without extra external devices. The series offers multiple MPPT inputs, giving designers greater freedom when laying out strings under uneven shading or varying roof orientations. Thanks to remote communication and integration with a monitoring platform, installers and facility managers can track system performance continuously and quickly spot deviations from normal operation. This is a solution for installation companies seeking proven European technology with low servicing costs throughout the installation's entire lifecycle.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.4% 98.2% Strong · top 15% 44
MPPT trackers 3 4 Weak · bottom 17% 214
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.2 1.2 Typical 264
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 60 kW Continuous output
Max AC power 66.00 kW Short-term output above the rating
Max apparent power 66.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 320...480 V
Max AC current 80.0 A
Grid frequency 50 Hz Range 47...53 Hz / 57...63 Hz
Power factor 0...1 inductive/capacitive with maximum Sn
Harmonic distortion (THD) 3.0 %
Max DC input power 61.80 kW DC/AC ratio 1.03
Max DC voltage 1000 V Caps the string length
MPPT voltage range 480 to 800 V
Start-up voltage 420 V
MPPT trackers 3 5 strings each
Max input current per MPPT 36.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 55.0 A Must exceed the panel's Isc
European efficiency 98.4 % Weighted across part loads
Max efficiency 98.6 % Best single operating point
Dimensions 750 × 1100 × 257 mm Height × width × depth
Weight 70.0 kg 1.2 kg per kW
Enclosure IP65
Cooling forced-air
Noise 75 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS-485Ethernet (RJ45)WLAN (IEEE802.11 b/g/n)Modbus RTU/TCPSunspecAurora Protocol
Protection DC switchSurge protection
Certifications CEIEC/EN 62109-1IEC/EN 62109-2EN 61000-6-2EN 61000-6-3EN 61000-3-11EN 61000-3-12EN 62311EN 301 489-1EN 301 489-17EN 300 328CEI 0-21CEI 0-16DIN V VDE V 0126-1-1VDE-AR-N 4105G59/3EN 50438RD 1565RD 413UTE C15-7-712-1AS/NZS 4777.3BDEWNRS-097-2-1IEC 61727IEC 61683IEC 62116Synergrid C10/11CLC-TS-50549-1/-2G99EN 50549-1/-2

Pros and cons

5 positive · 2 caution
What owners get
Wide power range 10-175 kW

The PVS-TL series spans from 10 kW (PVS-10-TL) up to 175 kW (PVS-175-TL), covering commercial, industrial, and large-roof installations on a single, familiar service platform.

ABB technology heritage

FIMER acquired ABB's string inverter business in 2020, meaning the PVS-TL series is built on a proven, extensively field-tested electronic platform previously used in ABB products across European markets.

Extensive MPPT inputs

Depending on the model, the series offers from 2-4 MPPTs (e.g., PVS-20/30/33-TL) up to 12 MPPTs in the 75-125 kW variants, giving significant string design flexibility under uneven shading conditions.

Optional AFCI and export power limitation

Units can be equipped with an optional arc-fault circuit interrupter (UL 1699B compliant in US variants) plus a built-in export power limitation function, eliminating the need for external control devices.

Compact, lightweight mounting design

The low unit weight allows installation without additional lifting equipment, shortening install time in hard-to-access locations such as industrial roof applications.

Trade-offs
Discontinued, limited service support

The PVS-TL series was discontinued (2021-2024) following FIMER's financial difficulties. Resellers such as Solarics list models like the PVS-10-TL and PVS-120-TL as End-of-Life, indicating limited availability of genuine spare parts and manufacturer support.

AFCI offered as optional, not standard

The arc-fault circuit interrupter is available as an optional add-on across most models (e.g., PVS-10/12.5/15-TL, PVS-20/30/33-TL) rather than standard equipment, adding cost for installations requiring enhanced fire safety.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER PVS-60-TL 60 kW 98.4% 3 70.0 kg You are here
SUN2000-60KTL-M0 60 kW 98.7% 6 74.0 kg +3 MPPT, 4.0 kg heavier
SG60KTL-182 60 kW 98.7% 1 60.0 kg -2 MPPT, 10.0 kg lighter
GW60KN-MT 60 kW 98.5% 4 64.0 kg +1 MPPT, 6.0 kg lighter
Solis-60K-4G 60 kW 98.5% 4 63.0 kg +1 MPPT, 7.0 kg lighter
BNT060KTL 60 kW 98.5% - 51.0 kg 19.0 kg lighter
XG60KTR 60 kW 98.5% 4 50.0 kg +1 MPPT, 20.0 kg lighter
XG60KTRL 60 kW 98.5% 4 50.0 kg +1 MPPT, 20.0 kg lighter
MAX 60KTL3 LV 60 kW 98.4% - 82.0 kg 12.0 kg heavier

About the PVS-TL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Are FIMER PVS-TL inverters still available for purchase?
The PVS-TL series has been discontinued from active production. FIMER went through financial difficulties and restructuring in 2023, and its assets were subsequently acquired by the McLaren Applied group. In practice, new PVS-TL units are now available mainly from distributor stock, so installers should confirm spare parts availability and long-term service support before purchasing.
How many MPPT inputs does the FIMER PVS-TL inverter have, and what does that mean for system design?
The number of MPPT inputs varies by model within the PVS-TL series, ranging from 2 on the smaller 10-15 kW units up to 12 on the larger industrial 75-125 kW models. More MPPT inputs let designers split a system into independent strings facing different orientations or experiencing different shading levels, increasing total energy yield on irregular commercial roofs and industrial buildings.
Does the PVS-TL inverter have a built-in arc fault circuit interrupter (AFCI)?
Yes, on most PVS-TL models AFCI is offered as an optional feature added to the base configuration, while US market variants often include it as standard. The detector identifies dangerous arcs, for example from damaged string connectors, and automatically disconnects the DC side, reducing fire risk on commercial buildings with large roof areas.
How does per-string current monitoring on the PVS-TL differ from standard inverter monitoring?
Standard monitoring only reports parameters for the whole inverter, while the PVS-TL measures current on each individual string separately. This lets a technician immediately see which specific module chain has stopped performing correctly, without physically checking every string on the roof. It cuts fault diagnosis time from hours to minutes, which matters on large installations on industrial halls.
Can the FIMER PVS-TL inverter limit exported power to the grid?
Yes, the PVS-TL includes a built-in export power limitation function without requiring additional external meters or controllers. This is useful when the grid operator imposes a cap on power fed back from the installation, which is common for large commercial systems connected to weaker sections of the low- or medium-voltage grid.
What are the alternatives to FIMER PVS-TL now that the series has been discontinued?
Since the PVS-TL is no longer manufactured, installers looking for comparable three-phase string inverters for commercial and industrial use typically consider manufacturers such as Huawei, SMA, Sungrow, or Fronius, which offer similar power ranges and per-string monitoring features. When replacing a failed PVS-TL unit, check MPPT voltage ranges and connector compatibility with the existing DC wiring.