Skip to main content

FIMER FIMER PVR-80-TL

80 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
80.00
Strong · top 22%
Euro eff. (%)
98.2
Typical · median 98.2%
MPPT
6
Typical · median 4
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
125.0
Weak · 50.0 kg above median
Warranty (yrs)
-
Not published

The PVR-65/75/80-TL series is an inverter platform built to solve one very specific problem: retrofitting aging photovoltaic plants originally equipped with central inverters. Output voltages matched to the legacy infrastructure (270, 300 and 320 Vac) let operators swap out the old central inverter without rebuilding the transformer or the AC cabling, which drastically cuts the time and cost of plant revamping. The inverters use a transformerless design together with a double-stage conversion topology, allowing them to handle a wide range of input voltages even with older, non-standard module strings. With up to 6 independent MPPTs, energy production is optimized even under partial shading conditions, while the modular, configurable wiring compartment makes it easy to adapt the unit to different plant layouts. An IP66 protection rating enclosure ensures resistance to moisture and dust in demanding field conditions. Thanks to remote monitoring via Wi-Fi and Ethernet and integration with a cloud-based platform, managing multiple inverters across a large installation stays simple and predictable. This solution is aimed primarily at owners and service teams of large commercial and industrial plants who want to extend the lifespan and profitability of their assets without investing in a costly rebuild of the electrical infrastructure.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.2% 98.2% Typical 186
MPPT trackers 6 4 Typical 55
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.6 1.2 Weak · bottom 24% 393
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 80 kW Continuous output
Max apparent power 80.00 kVA
Phases Three-phase
Nominal AC voltage 270 V 216-360 V (varies by model: 216-324V/240-360V/256-360V)
Max AC current 145.0 A
Grid frequency 50 Hz Range 45-55 Hz / 55-65 Hz
Power factor >0.995, 0...1 inductive/capacitive with maximum Smax
Harmonic distortion (THD) 3.0 %
Max DC input power 82.00 kW DC/AC ratio 1.02
Max DC voltage 1000 V Caps the string length
MPPT voltage range 385 to 800 V
Start-up voltage 420 V
MPPT trackers 6 4 strings each
Max input current per MPPT 36.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 98.2 % Weighted across part loads
Max efficiency 98.4 % Best single operating point
Dimensions 869 × 1086 × 419 mm Height × width × depth
Weight 125.0 kg 1.6 kg per kW
Enclosure IP66
Cooling forced-air
Noise 68 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces Wi-FiEthernetDisplay
Protocols Ethernet (RJ45)WLAN (IEEE 802.11 b/g/n @ 2.4 GHz)RS485Modbus RTU/TCP (SunSpec compliant)
Protection DC switchSurge protection
Certifications CERCMIEC/EN 62109-1IEC/EN 62109-2EN 61000-6-2EN 61000-6-4CEI 0-16

Pros and cons

5 positive · 2 caution
What owners get
Dedicated AC voltages for revamping

Output voltages of 270, 300 and 320 Vac match the transformers of legacy central-inverter plants, avoiding any AC-side rebuild and dramatically cutting the time and cost of a revamping project compared to replacing the whole AC infrastructure.

Up to 6 independent MPPT trackers

A six-channel MPPT configuration allows reliable operation under partial shading or asymmetric string layouts, a clear advantage over the single- or dual-MPPT central inverters typically found in the aging plants this series is designed to replace.

High conversion efficiency

A maximum efficiency of up to 98.9% (per FIMER catalogue data) places the PVR-TL series on par with current tier-1 string inverters, despite the platform being engineered specifically for retrofit rather than new installations.

IP66 enclosure for harsh outdoor conditions

The IP66 protection rating ensures full resistance to dust and water jets, allowing the unit to be mounted outdoors near the original central inverter location without needing an additional shelter or container.

Remote Wi-Fi/Ethernet monitoring and cloud integration

Built-in Wi-Fi, Ethernet and RS-485 connectivity, together with integration into the FIMER cloud platform, simplifies managing multiple distributed units across a large commercial plant that previously relied on a single central inverter monitoring point.

Trade-offs
Manufacturer ownership instability

FIMER went through insolvency proceedings in 2023 (Milan court), with its assets acquired by MA Solar Italy / McLaren Applied during 2024-2025. While the series is not formally discontinued, this restructuring history raises long-term risk around spare-parts and service availability compared to stable tier-1 manufacturers without an insolvency record.

Very narrow application niche

The platform is optimized exclusively for revamping central-inverter plants with specific transformer output voltages (270/300/320 Vac), practically excluding its use in new projects or plants with different AC parameters - this narrows the addressable market compared to general-purpose string inverters.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER FIMER PVR-80-TL 80 kW 98.2% 6 125.0 kg You are here
MAX 80KTL3 LV 80 kW 98.5% - 86.0 kg 39.0 kg lighter
M88H_121 80 kW 98.5% 2 84.0 kg -4 MPPT, 41.0 kg lighter
M88H_122 80 kW 98.5% 2 84.0 kg -4 MPPT, 41.0 kg lighter
GW80KBF-MT 80 kW 98.4% 4 65.0 kg -2 MPPT, 60.0 kg lighter
GW80KHV-MT 80 kW 98.4% 4 65.0 kg -2 MPPT, 60.0 kg lighter
FTH80T-S3 80 kW 98.4% 6 70.0 kg 55.0 kg lighter
ASW80K-LT 80 kW 98.4% - 86.0 kg 39.0 kg lighter
GW80K-MT 80 kW 98.3% 4 70.0 kg -2 MPPT, 55.0 kg lighter

About the PVR-TL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Can the FIMER PVR-TL inverter replace an old central inverter without rebuilding the transformer and AC wiring?
Yes, that is the core purpose of this series. The PVR-65/75/80-TL inverters offer AC output voltages matched to existing infrastructure (270, 300, or 320 Vac), so they can replace an aging central inverter without swapping the MV/LV transformer or rerouting AC cabling. This can cut revamping time to just a few days and significantly reduces modernization costs compared to a full transformer station rebuild.
How many MPPTs does the PVR-TL inverter have, and does it improve energy yield under partial shading?
The series uses up to 6 independent MPPT trackers, allowing separate monitoring and optimization of different string groups. In large-scale installations where parts of the PV field are shaded by masts, nearby structures, or soiling, this number of MPPTs limits the energy losses that occur when the whole system is forced to operate at the level of the weakest module string.
What power rating and DC voltage does the PVR-65/75/80-TL inverter support?
The series covers three power variants: 65, 75, and 80 kW, with a maximum DC input voltage of up to 1000 V. Its transformerless design with a dual conversion stage accepts a wide range of input voltages, which matters when retrofitting older installations where legacy module strings may have non-standard electrical parameters not seen in newer PV designs.
Can the PVR-TL inverter be installed outdoors in harsh site conditions with dust and moisture?
Yes, the enclosure has an IP66 protection rating, meaning full resistance to dust ingress and powerful water jets. The inverter can be mounted directly outdoors, for example at open-field solar farms exposed to dust or high humidity, without needing an additional shelter or technical enclosure to protect the unit.
How can multiple PVR-TL inverters be managed across a large commercial installation?
The PVR-65/75/80-TL inverters include built-in Wi-Fi, Ethernet, and RS-485 communication, enabling integration with the FIMER cloud platform. This lets installers and asset owners remotely monitor performance, generate production reports, and detect faults on individual units without needing to be physically on site, which is especially valuable for large industrial PV plants.
How does the PVR-TL inverter differ from the traditional central inverters it is designed to replace?
Unlike older transformer-based central inverters, the PVR-TL uses a transformerless design with a dual conversion stage and a modular, configurable junction box. This makes it lighter, more flexible for adapting to different plant topologies, and equipped with up to 6 MPPTs, a feature legacy central units typically lacked, resulting in greater flexibility and efficiency during revamping projects.