FIMER FIM-HY-8.0-SE-A-3PH

FIMER FIM-HY-8.0-SE-A-3PH

8 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
8.00
Typical for its class
Euro eff. (%)
97.3
Typical · median 97.5%
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 800 V
Weight (kg)
18.0
Typical · median 27.0 kg
Warranty (yrs)
-
Not published

FIMER PowerTRIO is a series of three-phase hybrid inverters designed for installations combining solar generation with energy storage. The series solves one of the most common pain points for prosumers - lack of flexibility in battery system configuration - by supporting DC- or AC-coupled setups, allowing installers to choose the topology that best fits a given project, whether it's a new installation or a retrofit. A key advantage is full-power backup even under unbalanced loads across phases, delivering real energy security for homes and small businesses during grid outages. System safety is reinforced by a patented arc-fault detection system (AFCI), reducing the risk of fire in DC wiring. The inverters also stand out thanks to a high DC/AC oversizing ratio, enabling more panel capacity than nominal AC output and improving energy harvest during periods of lower irradiance. Low operating noise and built-in connectivity (Wi-Fi, Ethernet) simplify installation in residential buildings and remote monitoring of system performance. With support for multiple units running in parallel, the PowerTRIO series scales from single-family homes to larger commercial installations, giving installers one versatile hybrid solution.

Ranking

839 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.3% 97.5% Typical 364
MPPT trackers 2 2 Typical 145
Max DC input voltage 1000 V 800 V Typical 135
Weight per kW 2.2 3.0 Typical 243
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 8 kW Continuous output
Max apparent power 8.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 320-480 V
Max AC current 12.2 A
Grid frequency 50 Hz Range 45-55 Hz / 55-65 Hz
Power factor >0.995, adj. ±0.8-1 (over/under excited)
Harmonic distortion (THD) 3.0 %
Max DC input power 12.00 kW DC/AC ratio 1.50
Max DC voltage 1000 V Caps the string length
MPPT trackers 2 1 string each
Max short-circuit current per MPPT 20.0 A Must exceed the panel's Isc
European efficiency 97.3 % Weighted across part loads
Max efficiency 97.9 % Best single operating point
Battery port Yes
Battery voltage 600-980 V
Max charge current 17.0 A
Max discharge current 17.0 A
Dimensions 373 × 518 × 183 mm Height × width × depth
Weight 18.0 kg 2.2 kg per kW
Enclosure IP65
Cooling natural
Noise 40 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 3000 m
Interfaces Wi-FiEthernet
Protocols Wi-FiEthernetRS-485Modbus TCP (SunSpec)USB
Protection AFCIDC switchSurge protection
Certifications CERCMIEC 62109-1IEC 62109-2IEC 62477-1EN IEC 61000-6-1EN IEC 61000-6-2EN IEC 61000-6-3EN IEC 61000-6-4EN 61000-3-2EN 61000-3-3EN 61000-3-11EN 61000-3-12CEI 0-16CEI 0-21DIN V VDE V 0126-1-1VDE-AR-N 4105G98 Issue 2G99 Issue 2AS/NZS 4777.2EN 50549-10IEC 61727IEC 62116EN 62116

Pros and cons

4 positive · 2 caution
What owners get
DC- or AC-coupled battery flexibility

PowerTRIO supports both DC-coupled and AC-coupled battery topologies, letting installers pick the configuration best suited to a new installation or a retrofit of existing PV with storage - a rare trait among three-phase hybrids in this power class.

Full backup power under unbalanced loads

The series delivers 100% backup power even with uneven load distribution across phases, meaning a single high-draw appliance on one phase won't reduce available UPS power on the others - most competing three-phase hybrids require balanced loads for full backup output.

Patented AFCI and low noise level

An integrated, patented arc-fault circuit interrupter (AFCI) reduces DC wiring fire risk, and a noise level below 20 dB(A) per manufacturer datasheet allows indoor installation in residential buildings without acoustic nuisance.

High DC/AC oversizing ratio and parallel operation

A high DC/AC ratio allows connecting more PV capacity than the inverter's nominal AC output, boosting yield during low-irradiance periods, while multi-unit parallel operation lets the same series scale from single-family homes to commercial installations on one platform.

Trade-offs
History of manufacturer financial instability

FIMER went through creditor-protection proceedings and insolvency in 2022-2023, with the inverter business only acquired by McLaren Applied Group (MA Solar Italy) in November 2024. For systems carrying 10-25 year warranties, this represents a real service and spare-parts continuity risk, even though the PowerTRIO series itself is not formally discontinued.

No publicly stated warranty term

Available product documentation (manual, QIG) refers warranty terms to separate Terms and Conditions supplied with the order, without an explicit duration in years - unlike competitors (e.g., Huawei, SolarEdge) that routinely publish 10+ year warranties for hybrid inverters in marketing materials.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER FIM-HY-8.0-SE-A-3PH 8 kW 97.3% 2 18.0 kg You are here
SE8000H 8 kW 99.0% - 19.6 kg +1.7 pp efficiency, 1.6 kg heavier
SigenStor Neo EC 8.0 TP 8 kW 98.6% - 30.0 kg +1.3 pp efficiency, 12.0 kg heavier
Sigen Hybrid 8.0 TP2 8 kW 98.5% 2 19.5 kg +1.2 pp efficiency, 1.5 kg heavier
8.0 LAN 8 kW 98.3% 2 32.0 kg +1.0 pp efficiency, 14.0 kg heavier
HYX-H8K-HSA2 8 kW 98.2% - 38.0 kg +0.9 pp efficiency, 20.0 kg heavier
HYX-H8K-HT 8 kW 98.2% 2 34.0 kg +0.9 pp efficiency, 16.0 kg heavier
MOD 8000TL3-XH 8 kW 98.1% 2 14.0 kg +0.8 pp efficiency, 4.0 kg lighter
MOD 8000TL3-HU 8 kW 98.1% 2 19.0 kg +0.8 pp efficiency, 1.0 kg heavier

About the PowerTRIO series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the difference between DC and AC coupling in FIMER PowerTRIO inverters, and which one should I choose?
DC coupling means the battery connects to the same DC circuit as the solar panels, giving higher charging efficiency in new installations. AC coupling lets you add an energy storage system independently of the existing PV array, which is more convenient when retrofitting an older system without touching the DC wiring. PowerTRIO supports both topologies, so the choice depends on whether the installation is new or being upgraded.
Will PowerTRIO provide full backup power to a home if the load is unbalanced across phases?
Yes, this is one of the series' key advantages. Most hybrid inverters limit backup power when loads are unbalanced across phases, but PowerTRIO delivers full backup power output regardless of how loads are distributed across phases. In practice, this means a refrigerator on one phase and air conditioning on another will keep running without interruption during a grid outage.
What does the AFCI system in PowerTRIO inverters do, and is it mandatory?
AFCI (Arc Fault Circuit Interrupter) is FIMER's patented arc-fault detection system for DC wiring, which automatically disconnects the installation when it detects abnormal arcing, before it can ignite a fire. This reduces fire risk caused by a damaged connector or chafed cable on the roof. In many countries, including under certain insurance requirements, this kind of protection is increasingly required or strongly recommended.
Can I connect more panel power to a PowerTRIO inverter than its rated AC output?
Yes, PowerTRIO has a high DC/AC oversizing ratio, allowing you to connect PV capacity that significantly exceeds the inverter's rated AC power. This configuration increases energy yield during morning, afternoon, and low-irradiance periods, when panels don't reach peak output anyway. The exact maximum oversizing ratio for a specific model should be checked in that variant's datasheet.
Can PowerTRIO inverters be connected in parallel for larger commercial installations?
Yes, PowerTRIO supports parallel operation of multiple units, allowing the system to scale from a single-family home up to a larger commercial installation without changing hardware platforms. For installers, this means one hardware solution and one monitoring interface regardless of project size, simplifying standardization of offers and service.
Is installing PowerTRIO in a residential building, e.g., a garage next to a bedroom, a problem due to noise?
It shouldn't be, since PowerTRIO features low operating noise thanks to cooling optimized for indoor installations. This allows the inverter to be mounted in utility rooms, garages, or hallways close to living spaces without worrying about the unpleasant fan noise typical of older, higher-power inverter models.