Skip to main content
Felicity Solar IVGM100KHP3G1

Felicity Solar IVGM100KHP3G1

100 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
100.00
Strong · top 8%
Euro eff. (%)
-
Not published
MPPT
8
Strong · top 17%
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
156.0
Weak · 81.0 kg above median
Warranty (yrs)
10
Strong · top 14%

The IVGM series comprises high-voltage, three-phase hybrid inverters ranging from 75 to 125 kW, built for commercial and industrial installations where power continuity and configuration flexibility are essential. Its standout feature is 0 ms grid-to-off-grid transfer, which eliminates power interruptions to critical production processes during grid outages. The system supports dual independent LFP battery banks, enabling stable operation under heavy peak loads and allowing energy storage capacity to be expanded in stages. Thanks to 2x PV input oversizing, developers can design arrays with surplus module capacity without sacrificing conversion efficiency, lowering the LCOE of the generated energy. The inverters can be combined in arrays of up to 12 units in parallel, letting the series scale from a single facility to large industrial plants and technology parks. An IP66-rated enclosure along with an active PID recovery function protect the investment for years, even in demanding environmental conditions. The IVGM series integrates with generators, smart load management systems, and microinverters, making it a versatile choice for integrators building hybrid power systems for manufacturing facilities, warehouses, and commercial sites that demand high power reliability.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers 8 4 Strong · top 17% 45
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.6 1.2 Weak · bottom 24% 392
Warranty 10 yrs 5 yrs Strong · top 14% 8
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 100 kW Continuous output
Max apparent power 110.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 220/380,230/400 Vac (-20%~+15%)
Max AC current 159.4 A
Grid frequency 50 Hz Range 45~55 Hz/55~65 Hz
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 200.00 kW DC/AC ratio 2.00
Max DC voltage 1000 V Caps the string length
MPPT voltage range 416 to 850 V
Start-up voltage 180 V
MPPT trackers 8 2 strings each
Max input current per MPPT 45.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 68.0 A Must exceed the panel's Isc
Battery port Yes
Battery voltage 160~1000Vdc
Max charge current 240.0 A
Max discharge current 240.0 A
Grid-forming Yes
Dimensions 814 × 1271 × 380 mm Height × width × depth
Weight 156.0 kg 1.6 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -40 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols RS485CANWIFIBluetooth4GLAN
Protection AFCISurge protection
Warranty 10 years Standard manufacturer cover
Certifications IEC 61727IEC 62116CEI 0-21EN 50549NRS 097RD 140UNE 217002OVE-Richtlinie R25G99VDE-AR-N 4110IEC/EN 61000-6-1/2/3/4IEC/EN 62109-1IEC/EN 62109-2

Pros and cons

5 positive · 2 caution
What owners get
0 ms grid-to-off-grid switching

The IVGM series eliminates power interruption during transition from grid to island mode, which is critical for production lines and continuous processes where even a short voltage dip causes downtime or material losses.

Dual independent LFP battery banks

Support for two separate LFP battery banks allows staged expansion of energy storage without replacing the inverter and better distribution of peak loads, a feature rarely found in commercial inverters of this power class.

2x PV input oversizing

This function allows installing PV module capacity up to twice the rated inverter power without losing AC conversion efficiency, lowering the unit cost (per kWh) of energy produced in commercial installations.

Scalability up to 12 parallel units

Combining up to 12 inverters in a parallel setup enables building systems from single sites to large industrial plants without changing the hardware platform, simplifying project standardization for integrators.

IP66 enclosure with active PID recovery

IP66 protection class combined with active PID recovery function protects PV modules from potential-induced degradation, which matters for industrial installations exposed to harsh environmental conditions (dust, humidity).

Trade-offs
Lower brand recognition in the C&I segment

Felicity Solar has significantly less presence in large commercial and industrial installations (75-125 kW) than tier-1 players such as Huawei, Sungrow, or SMA, which may mean harder access to local service support and fewer reference deployments for investors assessing long-term risk.

No publicly available independent performance testing

Unlike tier-1 inverters covered by DNV/BNEF Tier 1 reports, no publicly available independent tests of conversion efficiency or long-term durability in real-world conditions were found for the 75-125 kW IVGM series, making it harder to benchmark against competitors beyond manufacturer claims.

Inverter Power Euro eff. MPPT Weight Difference
Felicity Solar IVGM100KHP3G1 100 kW - 8 156.0 kg You are here
100M1-HYB 100 kW 98.4% - 108.0 kg 48.0 kg lighter
100M1-HYA 100 kW 98.4% - 78.0 kg 78.0 kg lighter
SUN-100K-SG02HP3-EU-GM8 100 kW 98.1% 10 161.7 kg +2 MPPT, 5.7 kg heavier
SUN-100K-SG02HP3-EU-GM10 100 kW 98.1% 10 161.7 kg +2 MPPT, 5.7 kg heavier
SUN-100K-SG02HP3-US-EM6-277V 100 kW 98.1% 6 - -2 MPPT
H3-100-Plus 100 kW 98.1% - 120.0 kg 36.0 kg lighter
P3-100-Plus 100 kW 98.1% - 120.0 kg 36.0 kg lighter
100TL 100 kW 98.1% - 80.0 kg 76.0 kg lighter

About the IVGM Series series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the 0 ms grid-to-off-grid switching in IVGM inverters and why does it matter?
This feature instantly switches power supply from the grid to island mode operation (batteries/PV) the moment a grid outage occurs, with zero interruption to the power supply. In practice, this means production lines, servers, or cold storage will not experience any voltage drop. This is critical for commercial and industrial facilities where even a millisecond-long interruption can cause equipment failure or data loss.
What power ratings are available in the IVGM series and what installations are they suited for?
The IVGM series includes three-phase hybrid inverters ranging from 75 to 125 kW. This power range is designed for commercial and industrial installations - warehouses, manufacturing plants, technology parks, and larger service facilities - rather than single-family homes. Thanks to the ability to connect up to 12 units in parallel, the system can scale all the way up to large industrial installations.
What does dual independent LFP battery banks mean in IVGM inverters?
The inverter can support two separate lithium iron phosphate (LFP) battery banks operating independently of each other. This design ensures stable performance under heavy peak loads and allows energy storage capacity to be expanded in stages - a second battery bank can be added later without replacing the entire system.
Can PV input be oversized in IVGM inverters, and by how much?
Yes, the IVGM series supports 2x PV input oversizing, meaning solar modules with up to twice the inverter's rated power can be installed without losing conversion efficiency. This allows the investor to increase energy yield from the installation and lower the levelized cost of energy (LCOE) while using the same inverter.
Are IVGM inverters suitable for harsh environmental conditions, such as industrial halls or outdoor installation?
Yes, the IP66-rated enclosure protects the inverter against dust and powerful water jets, allowing installation both inside production halls and outdoors. Additionally, the active PID regeneration function prevents voltage-induced degradation of PV modules, extending the lifespan of the entire installation even in demanding climatic conditions.
What systems and devices does the IVGM series integrate with?
IVGM inverters integrate with generators, load management systems, and microinverters, enabling the construction of complex hybrid systems tailored to specific facility needs. This versatility makes the series a popular choice among integrators designing installations for manufacturing companies and warehouses, where configuration flexibility and high power reliability are essential.