Skip to main content

ATESS HPS100KTL

100 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
100.00
Strong · top 8%
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
138.0
Typical · median 75.0 kg
Warranty (yrs)
-
Not published

The HPS KTL series is a line of three-phase hybrid inverters in the 100-125 kW class, built for small and medium commercial installations where both power output and supply reliability matter. The series stands out with its all-in-one design with a built-in ATS function, allowing the generator, grid, and energy storage to work together without the need for separate automatic transfer switches. A key advantage is seamless on-grid/off-grid transfer in under 10 ms, protecting sensitive loads such as cold storage or production lines from the effects of voltage loss. The series supports remote control of the diesel generator (DG) and programmable operating modes, making it easy to adapt the system to variable energy tariffs and production schedules. Thanks to multiple independent MPPT inputs, installers can flexibly combine PV strings with different orientations and shading conditions, reducing energy losses. The IP65-rated enclosure allows outdoor installation without additional shelter, while parallel operation of up to 10 units enables power scaling within a single installation without changing the system topology. This is a solution for integrators seeking a compact, weather-resistant hybrid inverter with high configuration flexibility for business, agricultural, and industrial applications.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers - 4 Not published -
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.4 1.2 Typical 349
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 100 kW Continuous output
Max apparent power 100.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 196-253Vac/340-440Vac
Max AC current 144.0 A
Grid frequency 50 Hz Range 45~55/55~65Hz
Power factor 0.8 lagging~0.8 leading
Harmonic distortion (THD) 3.0 %
Max DC input power 150.00 kW DC/AC ratio 1.50
Max DC voltage 1000 V Caps the string length
MPPT voltage range 125 to 850 V
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
Max efficiency 97.6 % Best single operating point
Battery port Yes
Battery voltage 150-950V
Max charge current 200.0 A
Max discharge current 200.0 A
Grid-forming Yes
Dimensions 680 × 960 × 300 mm Height × width × depth
Weight 138.0 kg 1.4 kg per kW
Enclosure IP65
Cooling forced-air
Noise 65 dB
Operating temperature -40 to 60 °C
Max humidity 100 %
Max altitude 5000 m
Interfaces Wi-FiDisplay
Protocols RS485CANWiFi4G
Protection AFCIDC switchSurge protection
Certifications Type II

Pros and cons

5 positive · 2 caution
What owners get
Seamless on/off-grid switching <10 ms

The built-in ATS function enables switching between the grid, generator, and energy storage in under 10 ms, as confirmed by official HPS100KTL/HPS125KTL datasheets. This removes the need for an external automatic transfer switch, shortening installation time and reducing BoS cost.

Remote generator and mode management

The series supports automatic diesel generator start/stop and load prioritization, combined with programmable operating modes, making it easier to optimize for variable energy tariffs - a feature rarely available in this power class without an additional controller.

High MPPT configuration flexibility

Multiple independent MPPT inputs allow stringing panels with different orientations and shading conditions within a single installation, reducing energy losses typical of commercial sites on irregular roofs or ground-mounted arrays.

IP65 enclosure and parallel operation up to 10 units

IP65-rated housing allows outdoor installation without an additional canopy, and the latest ATESS datasheets (2026) indicate parallel on&off-grid operation of up to 10 units, enabling capacity scaling to roughly 1.25 MW without changing system topology.

High declared conversion efficiency

The manufacturer states conversion efficiency of up to 97.6% for the 100 kW unit (HPS100000TL), in line with competing transformerless inverters in this power class.

Trade-offs
Young manufacturer with limited track record

ATESS was founded in 2017, so compared to established Tier-1 brands (Huawei, Sungrow, SMA) with 15-20 years of field history, the HPS KTL series has a shorter operational track record, which can matter for investors assessing long-term project bankability.

Inconsistent parallel-operation limit data

Manufacturer documentation published across different years states conflicting parallel-operation limits for the HPS series (ranging from 2, through 4 and 8, to 10 units in the newest sheets), making it harder to plan system scaling without verifying the current datasheet with a distributor.

Alternatives

All ATESS inverters
Inverter Power Euro eff. MPPT Weight Difference
ATESS HPS100KTL 100 kW - - 138.0 kg You are here
100M1-HYB 100 kW 98.4% - 108.0 kg 30.0 kg lighter
100M1-HYA 100 kW 98.4% - 78.0 kg 60.0 kg lighter
SUN-100K-SG02HP3-EU-GM8 100 kW 98.1% 10 161.7 kg 23.7 kg heavier
SUN-100K-SG02HP3-EU-GM10 100 kW 98.1% 10 161.7 kg 23.7 kg heavier
SUN-100K-SG02HP3-US-EM6-277V 100 kW 98.1% 6 - Similar on paper
H3-100-Plus 100 kW 98.1% - 120.0 kg 18.0 kg lighter
P3-100-Plus 100 kW 98.1% - 120.0 kg 18.0 kg lighter
100TL 100 kW 98.1% - 80.0 kg 58.0 kg lighter

About the HPS KTL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Does the HPS KTL inverter require a separate ATS switch to be purchased?
No, the HPS KTL series has an ATS function built directly into the inverter enclosure. The generator, utility grid, and energy storage system connect directly to the unit, eliminating the need for an external automatic transfer switch cabinet. This simplifies installation, reduces the number of components in the switchgear, and lowers material and labor costs compared to systems requiring a standalone ATS.
How fast does the HPS KTL switch from grid-tied to off-grid operation during a power outage?
Transfer between on-grid and off-grid operation occurs in under 10 ms, essentially seamless to connected loads. For cold storage, server rooms, or production lines with sensitive electronics, this means a grid outage does not cause downtime or data loss, since the battery storage or generator picks up the load almost instantly.
How many HPS KTL inverters can be connected together in a single installation?
This series supports parallel operation of up to 10 units, allowing total system power to scale beyond 1 MW without changing the system topology. This flexibility is useful when a business plans to expand its facility in phases and wants to add inverters incrementally to the existing array rather than investing in maximum capacity upfront.
Can the HPS KTL inverter be installed outdoors without a protective canopy?
Yes, the enclosure has an IP65 rating, providing full protection against dust and water jets from any direction. This allows the unit to be mounted on a facade, fence, or support structure outdoors without building an additional canopy, which is a common requirement for agricultural or industrial sites with limited indoor installation space.
Can the HPS KTL remotely control a diesel generator and schedule operating modes?
Yes, the series supports remote diesel generator control and programmable operating modes. Installers or operators can configure automatic generator start-up when the battery storage reaches a low state of charge, and align charge/discharge schedules with time-of-use electricity tariffs, helping reduce energy costs for businesses operating on variable production schedules.
How many independent MPPT inputs does the HPS KTL have and why does it matter?
The inverter features multiple independent MPPT inputs, allowing PV strings with different orientations, tilt angles, or shading conditions to be connected without reducing overall system performance. This lets installers design arrays for irregular roof geometries or sites with partial shading from chimneys or neighboring buildings, minimizing energy losses across the installation.