Skip to main content
YL460CF48 i/2 vs YL450CF54 e/2 11 of 19 identical Swap Change panels

Yingli YL460CF48 i/2 vs Yingli YL450CF54 e/2

Yingli YL460CF48 i/2
YL460CF48 i/2
460 Wp 23.00 % TOPCon Bifacial
VS
Yingli YL450CF54 e/2
YL450CF54 e/2
450 Wp 23.00 % TOPCon Bifacial
The verdict

YL460CF48 i/2 leads on the differences that matter

The largest is short-circuit current: 1.33 A apart. 11 of 19 comparable parameters are identical.

See all 8 differences
How alike are they
11 of 19 comparable
parameters are identical
identical differs
01

What actually differs

8 of 19 parameters
Parameter YL460CF48 i/2 YL450CF54 e/2 Difference
Short-circuit current 15.76 A 14.43 A 1.33 A apart
Open-circuit voltage 36.68 V 39.23 V 2.55 V apart
Module area 1.998 m² 1.953 m² 0.045 m² apart
Rated power 460 Wp 450 Wp 10 W more power
Cell count 96 108 12 cells apart
Current at max power 15.04 A 13.79 A 1.25 A apart
Voltage at max power 30.60 V 32.64 V 2.04 V apart
Dimensions 1762x1134x30 mm 1722x1134x30 mm 1762x1134x30 mm vs 1722x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
YL460CF48 i/2
15,434 kWh
YL450CF54 e/2
15,098 kWh
Lifetime gap
336 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario YL460CF48 i/2 YL450CF54 e/2
Standard test conditions 25 °C 100.0% of rated power 460 W 450 W
Cool, bright day 40 °C 95.7% of rated power 440 W 430 W
Typical summer roof 55 °C 91.3% of rated power 420 W 411 W
Hot roof 70 °C 87.0% of rated power 400 W 391 W
03

Full specification

Parameter YL460CF48 i/2 YL450CF54 e/2 Difference
Power and efficiency
Rated power 460 Wp 450 Wp +10 W for YL460CF48 i/2
Module efficiency 23.00 % 23.00 % Same
Power density 230.2 Wp/m² 230.4 Wp/m² Effectively the same
Open-circuit voltage 36.68 V 39.23 V 2.55 V apart
Voltage at max power 30.60 V 32.64 V 2.04 V apart
Short-circuit current 15.76 A 14.43 A 1.33 A apart
Current at max power 15.04 A 13.79 A 1.25 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1722x1134x30 mm 1762x1134x30 mm vs 1722x1134x30 mm
Module area 1.998 m² 1.953 m² 0.045 m² apart
Weight 20.7 kg 20.3 kg Effectively the same
Weight per kWp 45.0 kg/kWp 45.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 108 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#2,049 vs #2,049
Tied - the same position in the database
Power density
#2,011 vs #1,835
YL450CF54 e/2 leads by 176 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#579 vs #623
YL460CF48 i/2 leads by 44 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#8,206 vs #8,571
YL460CF48 i/2 leads by 365 places
05

More useful comparisons

Open the full database
Same series, other bin
Yingli YL460CF48 i/2 vs Yingli YL465CF48 i/2
One difference: module efficiency
Same series, other bin
Yingli YL460CF48 i/2 vs Yingli YL455CF54 e/2
8 differences, the largest is module efficiency
Same series, other bin
Yingli YL460CF48 i/2 vs Yingli YL455CF48 i/2
One difference: module efficiency
Same series, other bin
Yingli YL460CF48 i/2 vs Yingli YL450CF48 i/2
3 differences, the largest is module efficiency
Same series, other bin
Yingli YL460CF48 i/2 vs Yingli YL445CF54 e/2
9 differences, the largest is rated power
Same series, other bin
Yingli YL460CF48 i/2 vs Yingli YL445CF48 i/2
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Yingli YL460CF48 i/2 or Yingli YL450CF54 e/2?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Yingli YL460CF48 i/2 and Yingli YL450CF54 e/2?
Yingli YL460CF48 i/2 has a module efficiency of 23.00%, while Yingli YL450CF54 e/2 is 23.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Yingli YL460CF48 i/2 use vs Yingli YL450CF54 e/2?
Yingli YL460CF48 i/2 uses TOPCon cells; Yingli YL450CF54 e/2 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Yingli YL460CF48 i/2 and Yingli YL450CF54 e/2?
Yingli YL460CF48 i/2 has a 30 years power warranty; Yingli YL450CF54 e/2 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Yingli YL460CF48 i/2 and Yingli YL450CF54 e/2 bifacial panels?
Both Yingli YL460CF48 i/2 and Yingli YL450CF54 e/2 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 Yingli offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.