VSUN VSUN590N-144BMH-DG vs VSUN VSUN700N-132BMH-DG
VS
The verdict
11 differences, and they point both ways
The largest is rated power: 110 W more power. 8 of 19 comparable parameters are identical.
See all 11 differencesHow alike are they
8
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
11 of 19 parameters
What actually differs
Parameter
VSUN590N-144BMH-DG
VSUN700N-132BMH-DG
Difference
Rated power
590 Wp
700 Wp
110 W more power
Weight
32.7 kg
38.5 kg
5.8 kg lighter
Short-circuit current
14.49 A
18.32 A
3.83 A apart
Module area
2.583 m²
3.106 m²
0.523 m² apart
Module efficiency
22.84 %
22.53 %
0.31 pp more efficient
Open-circuit voltage
51.79 V
48.50 V
3.29 V apart
Power density
228.4 Wp/m²
225.3 Wp/m²
3.0 Wp/m² higher
Current at max power
13.69 A
17.29 A
3.60 A apart
Cell count
144
132
12 cells apart
Voltage at max power
43.11 V
40.50 V
2.61 V apart
Dimensions
2278x1134x35 mm
2384x1303x35 mm
2278x1134x35 mm vs 2384x1303x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.300 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
VSUN590N-144BMH-DG
19,796 kWh
VSUN700N-132BMH-DG
23,486 kWh
Lifetime gap
3,690 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
VSUN590N-144BMH-DG
VSUN700N-132BMH-DG
Standard test conditions
25 °C
100.0% of rated power
590 W
700 W
Cool, bright day
40 °C
95.5% of rated power
563 W
669 W
Typical summer roof
55 °C
91.0% of rated power
537 W
637 W
Hot roof
70 °C
86.5% of rated power
510 W
606 W
03
Full specification
Parameter
VSUN590N-144BMH-DG
VSUN700N-132BMH-DG
Difference
Power and efficiency
Rated power
590 Wp
700 Wp
+110 W for VSUN700N-132BMH-DG
Module efficiency
22.84 %
22.53 %
+0.31 pp for VSUN590N-144BMH-DG
Power density
228.4 Wp/m²
225.3 Wp/m²
+3.0 Wp/m² for VSUN590N-144BMH-DG
Open-circuit voltage
51.79 V
48.50 V
3.29 V apart
Voltage at max power
43.11 V
40.50 V
2.61 V apart
Short-circuit current
14.49 A
18.32 A
3.83 A apart
Current at max power
13.69 A
17.29 A
3.60 A apart
Temperature
Temperature coefficient
-0.300 %/°C
-0.300 %/°C
Same
Mechanical
Dimensions
2278x1134x35 mm
2384x1303x35 mm
2278x1134x35 mm vs 2384x1303x35 mm
Module area
2.583 m²
3.106 m²
0.523 m² apart
Weight
32.7 kg
38.5 kg
-5.8 kg for VSUN590N-144BMH-DG
Weight per kWp
55.4 kg/kWp
55.0 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
132
12 cells apart
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#2,767
vs
#4,151
VSUN590N-144BMH-DG leads by 1,384 places
Power density
#2,748
vs
#4,158
VSUN590N-144BMH-DG leads by 1,410 places
Heat behaviour
#6,298
vs
#6,298
Tied - the same position in the database
Weight
#10,061
vs
#9,567
VSUN700N-132BMH-DG leads by 494 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#3,897
vs
#1,229
VSUN700N-132BMH-DG leads by 2,668 places
05
Open the full database
More useful comparisons
Same series, other bin
VSUN
VSUN VSUN590N-144BMH-DG vs VSUN VSUN585N-144BMH-DG
The same specification on paper
Same series, other bin
VSUN
VSUN VSUN590N-144BMH-DG vs VSUN VSUN580N-144BMH-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN715N-132BMHT-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN710N-132BMHT-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN705N-132BMHT-DG
The same specification on paper
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN700N-132BMHT-DG
The same specification on paper
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: VSUN VSUN590N-144BMH-DG or VSUN VSUN700N-132BMH-DG?
According to our database: VSUN VSUN590N-144BMH-DG has higher module efficiency (22.84% vs 22.53%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of VSUN VSUN590N-144BMH-DG and VSUN VSUN700N-132BMH-DG?
VSUN VSUN590N-144BMH-DG has a module efficiency of 22.84%, while VSUN VSUN700N-132BMH-DG is 22.53%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does VSUN VSUN590N-144BMH-DG use vs VSUN VSUN700N-132BMH-DG?
VSUN VSUN590N-144BMH-DG uses TOPCon cells; VSUN VSUN700N-132BMH-DG uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on VSUN VSUN590N-144BMH-DG and VSUN VSUN700N-132BMH-DG?
VSUN VSUN590N-144BMH-DG has a 30 years power warranty; VSUN VSUN700N-132BMH-DG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are VSUN VSUN590N-144BMH-DG and VSUN VSUN700N-132BMH-DG bifacial panels?
Both VSUN VSUN590N-144BMH-DG and VSUN VSUN700N-132BMH-DG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 2 VSUN offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.