Skip to main content
SPV700-TG12-132BD vs SPV560-PM10-144 4 of 19 identical Swap Change panels

SpolarPV SPV700-TG12-132BD vs SpolarPV SPV560-PM10-144

SpolarPV SPV700-TG12-132BD
SpolarPV
SPV700-TG12-132BD
700 Wp 22.57 % TOPCon Bifacial
VS
SpolarPV SPV560-PM10-144
SpolarPV
SPV560-PM10-144
560 Wp 21.69 % PERC
The verdict

SPV700-TG12-132BD leads on the differences that matter

The largest is module efficiency: 0.88 pp more efficient. 4 of 19 comparable parameters are identical.

See all 15 differences
How alike are they
4 of 19 comparable
parameters are identical
identical differs
01

What actually differs

15 of 19 parameters
Parameter SPV700-TG12-132BD SPV560-PM10-144 Difference
Module efficiency 22.57 % 21.69 % 0.88 pp more efficient
Temperature coefficient -0.300 %/°C -0.350 %/°C 0.050 %/°C better in heat
Rated power 700 Wp 560 Wp 140 W more power
Weight 38.0 kg 26.5 kg 11.5 kg lighter
Power density 225.6 Wp/m² 217.0 Wp/m² 8.6 Wp/m² higher
Weight per kWp 54.3 kg/kWp 47.3 kg/kWp 7.0 kg/kWp lighter
Short-circuit current 18.35 A 13.82 A 4.53 A apart
Module area 3.103 m² 2.581 m² 0.522 m² apart
Open-circuit voltage 48.25 V 52.05 V 3.80 V apart
Cell technology TOPCon PERC TOPCon vs PERC
Current at max power 17.31 A 13.04 A 4.27 A apart
Cell count 132 144 12 cells apart
Bifacial Yes No Yes vs No
Voltage at max power 40.48 V 42.94 V 2.46 V apart
Dimensions 2383x1302x30 mm 2278x1133x30 mm 2383x1302x30 mm vs 2278x1133x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
SPV700-TG12-132BD
23,033 kWh
SPV560-PM10-144
18,441 kWh
Lifetime gap
4,592 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario SPV700-TG12-132BD SPV560-PM10-144
Standard test conditions 25 °C 100.0% of rated power 700 W 560 W
Cool, bright day 40 °C 94.8% of rated power 669 W 531 W
Typical summer roof 55 °C 89.5% of rated power 637 W 501 W
Hot roof 70 °C 84.2% of rated power 606 W 472 W
03

Full specification

Parameter SPV700-TG12-132BD SPV560-PM10-144 Difference
Power and efficiency
Rated power 700 Wp 560 Wp +140 W for SPV700-TG12-132BD
Module efficiency 22.57 % 21.69 % +0.88 pp for SPV700-TG12-132BD
Power density 225.6 Wp/m² 217.0 Wp/m² +8.6 Wp/m² for SPV700-TG12-132BD
Open-circuit voltage 48.25 V 52.05 V 3.80 V apart
Voltage at max power 40.48 V 42.94 V 2.46 V apart
Short-circuit current 18.35 A 13.82 A 4.53 A apart
Current at max power 17.31 A 13.04 A 4.27 A apart
Temperature
Temperature coefficient -0.300 %/°C -0.350 %/°C +0.050 %/°C for SPV700-TG12-132BD
Mechanical
Dimensions 2383x1302x30 mm 2278x1133x30 mm 2383x1302x30 mm vs 2278x1133x30 mm
Module area 3.103 m² 2.581 m² 0.522 m² apart
Weight 38.0 kg 26.5 kg -11.5 kg for SPV560-PM10-144
Weight per kWp 54.3 kg/kWp 47.3 kg/kWp -7.0 kg/kWp for SPV560-PM10-144
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.46 %/yr 0.45 %/yr Effectively the same
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 132 144 12 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,005 panels
Efficiency
#3,882 vs #7,530
SPV700-TG12-132BD leads by 3,648 places
Power density
#3,863 vs #7,429
SPV700-TG12-132BD leads by 3,566 places
Heat behaviour
#6,093 vs #10,419
SPV700-TG12-132BD leads by 4,326 places
Weight
#8,524 vs #1,639
SPV560-PM10-144 leads by 6,885 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#1,158 vs #5,929
SPV700-TG12-132BD leads by 4,771 places
05

More useful comparisons

Open the full database
Same series, other bin
SpolarPV
SpolarPV SPV700-TG12-132BD vs SpolarPV SPV695-TG12-132BD
The same specification on paper
Same series, other bin
SpolarPV
SpolarPV SPV700-TG12-132BD vs SpolarPV SPV690-TG12-132BD
3 differences, the largest is module efficiency
Same series, other bin
SpolarPV
SpolarPV SPV700-TG12-132BD vs SpolarPV SPV685-TG12-132BD
3 differences, the largest is module efficiency
Same series, other bin
SpolarPV
SpolarPV SPV560-PM10-144 vs SpolarPV SPV555-PM10-144
The same specification on paper
Same series, other bin
SpolarPV
SpolarPV SPV560-PM10-144 vs SpolarPV SPV550-PM10-144
3 differences, the largest is module efficiency
Same series, other bin
SpolarPV
SpolarPV SPV560-PM10-144 vs SpolarPV SPV545-PM10-144
4 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: SpolarPV SPV700-TG12-132BD or SpolarPV SPV560-PM10-144?
According to our database: SpolarPV SPV700-TG12-132BD has higher module efficiency (22.57% vs 21.69%); SpolarPV SPV700-TG12-132BD tolerates heat better (temp coeff -0.300%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of SpolarPV SPV700-TG12-132BD and SpolarPV SPV560-PM10-144?
SpolarPV SPV700-TG12-132BD has a module efficiency of 22.57%, while SpolarPV SPV560-PM10-144 is 21.69%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does SpolarPV SPV700-TG12-132BD use vs SpolarPV SPV560-PM10-144?
SpolarPV SPV700-TG12-132BD uses TOPCon cells; SpolarPV SPV560-PM10-144 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on SpolarPV SPV700-TG12-132BD and SpolarPV SPV560-PM10-144?
SpolarPV SPV700-TG12-132BD has a 30 years power warranty; SpolarPV SPV560-PM10-144 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are SpolarPV SPV700-TG12-132BD and SpolarPV SPV560-PM10-144 bifacial panels?
SpolarPV SPV700-TG12-132BD is bifacial (captures light from both faces); SpolarPV SPV560-PM10-144 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.