Solaria SPV665-TG12-132BD vs Solaria Solaria PowerX-400R
VS
The verdict
SPV665-TG12-132BD leads on the differences that matter
The largest is module efficiency: 0.94 pp more efficient. 2 of 16 comparable parameters are identical, with 3 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
2
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 16 parameters
What actually differs
Parameter
SPV665-TG12-132BD
Solaria PowerX-400R
Difference
Module efficiency
21.44 %
20.50 %
0.94 pp more efficient
Temperature coefficient
-0.300 %/°C
-0.360 %/°C
0.060 %/°C better in heat
Rated power
665 Wp
400 Wp
265 W more power
Performance warranty
30 yrs
25 yrs
5 yrs longer
Power density
214.3 Wp/m²
204.7 Wp/m²
9.6 Wp/m² higher
Weight
38.0 kg
22.1 kg
15.9 kg lighter
Product warranty
12 yrs
25 yrs
13 yrs longer
Open-circuit voltage
46.30 V
37.30 V
9.00 V apart
Short-circuit current
17.87 A
13.68 A
4.19 A apart
Module area
3.103 m²
1.954 m²
1.149 m² apart
Voltage at max power
39.00 V
31.00 V
8.00 V apart
Current at max power
17.06 A
12.90 A
4.16 A apart
Bifacial
Yes
No
Yes vs No
Dimensions
2383x1302x30 mm
1723x1134x35 mm
2383x1302x30 mm vs 1723x1134x35 mm
02
What it means on a roof
Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
SPV665-TG12-132BD
22,073 kWh
Solaria PowerX-400R
13,277 kWh
Lifetime gap
8,796 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
SPV665-TG12-132BD
Solaria PowerX-400R
Standard test conditions
25 °C
100.0% of rated power
665 W
400 W
Cool, bright day
40 °C
94.6% of rated power
635 W
378 W
Typical summer roof
55 °C
89.2% of rated power
605 W
357 W
Hot roof
70 °C
83.8% of rated power
575 W
335 W
03
Full specification
Parameter
SPV665-TG12-132BD
Solaria PowerX-400R
Difference
Power and efficiency
Rated power
665 Wp
400 Wp
+265 W for SPV665-TG12-132BD
Module efficiency
21.44 %
20.50 %
+0.94 pp for SPV665-TG12-132BD
Power density
214.3 Wp/m²
204.7 Wp/m²
+9.6 Wp/m² for SPV665-TG12-132BD
Open-circuit voltage
46.30 V
37.30 V
9.00 V apart
Voltage at max power
39.00 V
31.00 V
8.00 V apart
Short-circuit current
17.87 A
13.68 A
4.19 A apart
Current at max power
17.06 A
12.90 A
4.16 A apart
Temperature
Temperature coefficient
-0.300 %/°C
-0.360 %/°C
+0.060 %/°C for SPV665-TG12-132BD
Mechanical
Dimensions
2383x1302x30 mm
1723x1134x35 mm
2383x1302x30 mm vs 1723x1134x35 mm
Module area
3.103 m²
1.954 m²
1.149 m² apart
Weight
38.0 kg
22.1 kg
-15.9 kg for Solaria PowerX-400R
Weight per kWp
57.1 kg/kWp
55.2 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
25 yrs
+13 yrs for Solaria PowerX-400R
Performance warranty
30 yrs
25 yrs
+5 yrs for SPV665-TG12-132BD
Annual degradation
-
0.50 %/yr
Not published by Solaria
Technology
Cell technology
TOPCon
-
Not published by Solaria
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
-
Not published by Solaria
Bifacial
Yes
No
Yes vs No
04
14,005 panels
Against the whole database
Efficiency
#8,267
vs
#11,308
SPV665-TG12-132BD leads by 3,041 places
Power density
#8,232
vs
#11,499
SPV665-TG12-132BD leads by 3,267 places
Heat behaviour
#6,093
vs
#12,345
SPV665-TG12-132BD leads by 6,252 places
Weight
#11,052
vs
#9,691
Solaria PowerX-400R leads by 1,361 places
Warranty
#21
vs
#9,798
SPV665-TG12-132BD leads by 9,777 places
Overall
#2,776
vs
#10,732
SPV665-TG12-132BD leads by 7,956 places
05
Open the full database
More useful comparisons
Same series, other bin
Solaria
Solaria SPV665-TG12-132BD vs Solaria SPV680-TG12-132BD
3 differences, the largest is module efficiency
Same series, other bin
Solaria
Solaria SPV665-TG12-132BD vs Solaria SPV675-TG12-132BD
3 differences, the largest is module efficiency
Same series, other bin
Solaria
Solaria SPV665-TG12-132BD vs Solaria SPV670-TG12-132BD
The same specification on paper
Same series, other bin
Solaria
Solaria SPV665-TG12-132BD vs Solaria SPV660-TG12-132BD
The same specification on paper
Same series, other bin
Solaria
Solaria Solaria PowerX-400R vs Solaria Solaria PowerX-395R
One difference: module efficiency
Same series, other bin
Solaria
Solaria Solaria PowerX-400R vs Solaria Solaria PowerX-390R
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Solaria SPV665-TG12-132BD or Solaria Solaria PowerX-400R?
According to our database: Solaria SPV665-TG12-132BD has higher module efficiency (21.44% vs 20.50%); Solaria SPV665-TG12-132BD tolerates heat better (temp coeff -0.300%/°C vs -0.360%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Solaria SPV665-TG12-132BD and Solaria Solaria PowerX-400R?
Solaria SPV665-TG12-132BD has a module efficiency of 21.44%, while Solaria Solaria PowerX-400R is 20.50%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Solaria SPV665-TG12-132BD use vs Solaria Solaria PowerX-400R?
Solaria SPV665-TG12-132BD uses TOPCon cells; Solaria Solaria PowerX-400R uses Monocrystalline. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Solaria SPV665-TG12-132BD and Solaria Solaria PowerX-400R?
Solaria SPV665-TG12-132BD has a 30 years power warranty; Solaria Solaria PowerX-400R has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Solaria SPV665-TG12-132BD and Solaria Solaria PowerX-400R bifacial panels?
Solaria SPV665-TG12-132BD is bifacial (captures light from both faces); Solaria Solaria PowerX-400R is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 1 Solaria offer
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.