Skip to main content
PEAK DUO ML-G12S.3 / BFG 675 vs TRON BLK M-G2.H1+/AC (Power class 440W) 1 of 18 identical Swap Change panels

Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 vs Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)

Q.PEAK DUO ML-G12S.3 / BFG 675
675 Wp 21.70 % Bifacial
VS
Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)
Q.TRON BLK M-G2.H1+/AC (Power class 440W)
440 Wp 22.50 % N-type
The verdict

TRON BLK M-G2.H1+/AC (Power class 440W) leads on the differences that matter

The largest is module efficiency: 0.80 pp more efficient. 1 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 17 differences
How alike are they
1 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 18 parameters
Parameter PEAK DUO ML-G12S.3 / BFG 675 TRON BLK M-G2.H1+/AC (Power class 440W) Difference
Module efficiency 21.70 % 22.50 % 0.80 pp more efficient
Temperature coefficient -0.340 %/°C -0.300 %/°C 0.040 %/°C better in heat
Rated power 675 Wp 440 Wp 235 W more power
Performance warranty 30 yrs 25 yrs 5 yrs longer
Weight 38.2 kg 22.9 kg 15.3 kg lighter
Product warranty 12 yrs 25 yrs 13 yrs longer
Power density 217.3 Wp/m² 225.3 Wp/m² 8.0 Wp/m² higher
Annual degradation 0.45 %/yr 0.33 %/yr 0.12 %/yr slower
Open-circuit voltage 45.74 V 39.88 V 5.86 V apart
Short-circuit current 18.45 A 13.90 A 4.55 A apart
Module area 3.106 m² 1.953 m² 1.154 m² apart
Weight per kWp 56.6 kg/kWp 52.2 kg/kWp 4.4 kg/kWp lighter
Voltage at max power 38.43 V 33.33 V 5.10 V apart
Current at max power 17.56 A 13.20 A 4.36 A apart
Cell count 132 216 84 cells apart
Bifacial Yes No Yes vs No
Dimensions 2384x1303x35 mm 1722x1134x40 mm 2384x1303x35 mm vs 1722x1134x40 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
PEAK DUO ML-G12S.3 / BFG 675
22,228 kWh
TRON BLK M-G2.H1+/AC (Power class 440W)
14,844 kWh
Lifetime gap
7,384 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario PEAK DUO ML-G12S.3 / BFG 675 TRON BLK M-G2.H1+/AC (Power class 440W)
Standard test conditions 25 °C 100.0% of rated power 675 W 440 W
Cool, bright day 40 °C 94.9% of rated power 641 W 420 W
Typical summer roof 55 °C 89.8% of rated power 606 W 400 W
Hot roof 70 °C 84.7% of rated power 572 W 381 W
03

Full specification

Parameter PEAK DUO ML-G12S.3 / BFG 675 TRON BLK M-G2.H1+/AC (Power class 440W) Difference
Power and efficiency
Rated power 675 Wp 440 Wp +235 W for PEAK DUO ML-G12S.3 / BFG 675
Module efficiency 21.70 % 22.50 % +0.80 pp for TRON BLK M-G2.H1+/AC (Power class 440W)
Power density 217.3 Wp/m² 225.3 Wp/m² +8.0 Wp/m² for TRON BLK M-G2.H1+/AC (Power class 440W)
Open-circuit voltage 45.74 V 39.88 V 5.86 V apart
Voltage at max power 38.43 V 33.33 V 5.10 V apart
Short-circuit current 18.45 A 13.90 A 4.55 A apart
Current at max power 17.56 A 13.20 A 4.36 A apart
Temperature
Temperature coefficient -0.340 %/°C -0.300 %/°C +0.040 %/°C for TRON BLK M-G2.H1+/AC (Power class 440W)
Mechanical
Dimensions 2384x1303x35 mm 1722x1134x40 mm 2384x1303x35 mm vs 1722x1134x40 mm
Module area 3.106 m² 1.953 m² 1.154 m² apart
Weight 38.2 kg 22.9 kg -15.3 kg for TRON BLK M-G2.H1+/AC (Power class 440W)
Weight per kWp 56.6 kg/kWp 52.2 kg/kWp -4.4 kg/kWp for TRON BLK M-G2.H1+/AC (Power class 440W)
Warranty and degradation
Product warranty 12 yrs 25 yrs +13 yrs for TRON BLK M-G2.H1+/AC (Power class 440W)
Performance warranty 30 yrs 25 yrs +5 yrs for PEAK DUO ML-G12S.3 / BFG 675
Annual degradation 0.45 %/yr 0.33 %/yr -0.12 %/yr for TRON BLK M-G2.H1+/AC (Power class 440W)
Technology
Cell technology - N-type Not published by Q-Cells
Cell type Monocrystalline Monocrystalline Same
Cell count 132 216 84 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,005 panels
Efficiency
#7,421 vs #4,222
TRON BLK M-G2.H1+/AC (Power class 440W) leads by 3,199 places
Power density
#7,349 vs #4,099
TRON BLK M-G2.H1+/AC (Power class 440W) leads by 3,250 places
Heat behaviour
#8,778 vs #6,093
TRON BLK M-G2.H1+/AC (Power class 440W) leads by 2,685 places
Weight
#10,738 vs #5,625
TRON BLK M-G2.H1+/AC (Power class 440W) leads by 5,113 places
Warranty
#21 vs #9,798
PEAK DUO ML-G12S.3 / BFG 675 leads by 9,777 places
Overall
#2,198 vs #7,682
PEAK DUO ML-G12S.3 / BFG 675 leads by 5,484 places
05

More useful comparisons

Open the full database
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 670
The same specification on paper
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 665
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 655
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 650
4 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W) vs Q-Cells Q.TRON BLK M-G2.D1+/AC (Power class 435W)
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 or Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)?
According to our database: Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440 W) has higher module efficiency (22.50% vs 21.70%); Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440 W) tolerates heat better (temp coeff -0.300%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 and Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)?
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 has a module efficiency of 21.70%, while Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440 W) is 22.50%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 use vs Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)?
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 uses Monocrystalline cells; Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440 W) uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 and Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W)?
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 has a 30 years power warranty; Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440 W) has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 and Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440W) bifacial panels?
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675 is bifacial (captures light from both faces); Q-Cells Q.TRON BLK M-G2.H1+/AC (Power class 440 W) is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 28 Q-Cells offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.