Premier Energies PE-575 TB M10_1A vs Premier Energies PE-132-630-THGB-G12R
VS
The verdict
132-630-THGB-G12R leads on the differences that matter
The largest is module efficiency: 1.08 pp more efficient. 5 of 19 comparable parameters are identical.
See all 14 differencesHow alike are they
5
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
14 of 19 parameters
What actually differs
Parameter
575 TB M10_1A
132-630-THGB-G12R
Difference
Module efficiency
22.24 %
23.32 %
1.08 pp more efficient
Rated power
575 Wp
630 Wp
55 W more power
Power density
222.6 Wp/m²
233.2 Wp/m²
10.6 Wp/m² higher
Weight
28.0 kg
33.5 kg
5.5 kg lighter
Module area
2.583 m²
2.701 m²
0.118 m² apart
Short-circuit current
13.71 A
15.65 A
1.94 A apart
Weight per kWp
48.7 kg/kWp
53.2 kg/kWp
4.5 kg/kWp lighter
Temperature coefficient
-0.300 %/°C
-0.290 %/°C
0.010 %/°C better in heat
Cell technology
TOPCon
N-type
TOPCon vs N-type
Cell count
144
132
12 cells apart
Current at max power
13.06 A
14.96 A
1.90 A apart
Open-circuit voltage
51.30 V
49.61 V
1.69 V apart
Dimensions
2278x1134x35 mm
2382x1134x35 mm
2278x1134x35 mm vs 2382x1134x35 mm
Voltage at max power
44.03 V
42.13 V
1.90 V apart
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
575 TB M10_1A
19,292 kWh
132-630-THGB-G12R
21,138 kWh
Lifetime gap
1,846 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
575 TB M10_1A
132-630-THGB-G12R
Standard test conditions
25 °C
100.0% of rated power
575 W
630 W
Cool, bright day
40 °C
95.5% of rated power
549 W
603 W
Typical summer roof
55 °C
91.0% of rated power
523 W
575 W
Hot roof
70 °C
86.5% of rated power
497 W
548 W
03
Full specification
Parameter
575 TB M10_1A
132-630-THGB-G12R
Difference
Power and efficiency
Rated power
575 Wp
630 Wp
+55 W for 132-630-THGB-G12R
Module efficiency
22.24 %
23.32 %
+1.08 pp for 132-630-THGB-G12R
Power density
222.6 Wp/m²
233.2 Wp/m²
+10.6 Wp/m² for 132-630-THGB-G12R
Open-circuit voltage
51.30 V
49.61 V
1.69 V apart
Voltage at max power
44.03 V
42.13 V
1.90 V apart
Short-circuit current
13.71 A
15.65 A
1.94 A apart
Current at max power
13.06 A
14.96 A
1.90 A apart
Temperature
Temperature coefficient
-0.300 %/°C
-0.290 %/°C
+0.010 %/°C for 132-630-THGB-G12R
Mechanical
Dimensions
2278x1134x35 mm
2382x1134x35 mm
2278x1134x35 mm vs 2382x1134x35 mm
Module area
2.583 m²
2.701 m²
0.118 m² apart
Weight
28.0 kg
33.5 kg
-5.5 kg for 575 TB M10_1A
Weight per kWp
48.7 kg/kWp
53.2 kg/kWp
-4.5 kg/kWp for 575 TB M10_1A
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
N-type
TOPCon vs N-type
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
132
12 cells apart
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#5,911
vs
#1,075
132-630-THGB-G12R leads by 4,836 places
Power density
#5,738
vs
#1,105
132-630-THGB-G12R leads by 4,633 places
Heat behaviour
#6,298
vs
#2,288
132-630-THGB-G12R leads by 4,010 places
Weight
#2,443
vs
#7,148
575 TB M10_1A leads by 4,705 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#5,017
vs
#2,035
132-630-THGB-G12R leads by 2,982 places
05
Open the full database
More useful comparisons
Same series, other bin
Premier Energies
Premier Energies PE-575 TB M10_1A vs Premier Energies PE-590 TB M10_1A
3 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-575 TB M10_1A vs Premier Energies PE-585 TB M10_1A
3 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-575 TB M10_1A vs Premier Energies PE-580 TB M10_1A
One difference: module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-575 TB M10_1A vs Premier Energies PE-570 TB M10_1A
The same specification on paper
Same series, other bin
Premier Energies
Premier Energies PE-575 TB M10_1A vs Premier Energies PE-565 TB M10_1A
3 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-575 TB M10_1A vs Premier Energies PE-560 TB M10_1A
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Premier Energies PE-575 TB M10_1A or Premier Energies PE-132-630-THGB-G12R?
According to our database: Premier Energies PE-132-630-THGB-G12R has higher module efficiency (23.32% vs 22.24%); Premier Energies PE-132-630-THGB-G12R tolerates heat better (temp coeff -0.290%/°C vs -0.300%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Premier Energies PE-575 TB M10_1A and Premier Energies PE-132-630-THGB-G12R?
Premier Energies PE-575 TB M10_1A has a module efficiency of 22.24%, while Premier Energies PE-132-630-THGB-G12R is 23.32%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Premier Energies PE-575 TB M10_1A use vs Premier Energies PE-132-630-THGB-G12R?
Premier Energies PE-575 TB M10_1A uses TOPCon cells; Premier Energies PE-132-630-THGB-G12R uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Premier Energies PE-575 TB M10_1A and Premier Energies PE-132-630-THGB-G12R?
Premier Energies PE-575 TB M10_1A has a 30 years power warranty; Premier Energies PE-132-630-THGB-G12R has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Premier Energies PE-575 TB M10_1A and Premier Energies PE-132-630-THGB-G12R bifacial panels?
Both Premier Energies PE-575 TB M10_1A and Premier Energies PE-132-630-THGB-G12R are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.
