Philadelphia Solar PS-MNB156(HCBF)-650W vs Philadelphia Solar PS-MNB144(HCBF)-595W

Philadelphia Solar
PS-MNB156(HCBF)-650W
650 Wp
23.26 %
N-type
Bifacial
VS

Philadelphia Solar
PS-MNB144(HCBF)-595W
595 Wp
23.03 %
N-type
Bifacial
The verdict
9 differences, and they point both ways
The largest is rated power: 55 W more power. 10 of 19 comparable parameters are identical.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
9 of 19 parameters
What actually differs
Parameter
MNB156(HCBF)-650W
MNB144(HCBF)-595W
Difference
Rated power
650 Wp
595 Wp
55 W more power
Weight
32.5 kg
27.0 kg
5.5 kg lighter
Open-circuit voltage
56.55 V
52.07 V
4.48 V apart
Module area
2.794 m²
2.583 m²
0.211 m² apart
Weight per kWp
50.0 kg/kWp
45.4 kg/kWp
4.6 kg/kWp lighter
Module efficiency
23.26 %
23.03 %
0.23 pp more efficient
Cell count
156
144
12 cells apart
Voltage at max power
48.22 V
44.34 V
3.88 V apart
Dimensions
2464x1134x35 mm
2278x1134x30 mm
2464x1134x35 mm vs 2278x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
MNB156(HCBF)-650W
21,809 kWh
MNB144(HCBF)-595W
19,963 kWh
Lifetime gap
1,846 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
MNB156(HCBF)-650W
MNB144(HCBF)-595W
Standard test conditions
25 °C
100.0% of rated power
650 W
595 W
Cool, bright day
40 °C
95.7% of rated power
622 W
569 W
Typical summer roof
55 °C
91.3% of rated power
593 W
543 W
Hot roof
70 °C
87.0% of rated power
565 W
517 W
03
Full specification
Parameter
MNB156(HCBF)-650W
MNB144(HCBF)-595W
Difference
Power and efficiency
Rated power
650 Wp
595 Wp
+55 W for MNB156(HCBF)-650W
Module efficiency
23.26 %
23.03 %
+0.23 pp for MNB156(HCBF)-650W
Power density
232.6 Wp/m²
230.3 Wp/m²
Effectively the same
Open-circuit voltage
56.55 V
52.07 V
4.48 V apart
Voltage at max power
48.22 V
44.34 V
3.88 V apart
Short-circuit current
14.26 A
14.22 A
Effectively the same
Current at max power
13.48 A
13.44 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
2464x1134x35 mm
2278x1134x30 mm
2464x1134x35 mm vs 2278x1134x30 mm
Module area
2.794 m²
2.583 m²
0.211 m² apart
Weight
32.5 kg
27.0 kg
-5.5 kg for MNB144(HCBF)-595W
Weight per kWp
50.0 kg/kWp
45.4 kg/kWp
-4.6 kg/kWp for MNB144(HCBF)-595W
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
N-type
N-type
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
156
144
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#1,237
vs
#1,744
MNB156(HCBF)-650W leads by 507 places
Power density
#1,218
vs
#1,758
MNB156(HCBF)-650W leads by 540 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#3,317
vs
#708
MNB144(HCBF)-595W leads by 2,609 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#1,621
vs
#3,213
MNB156(HCBF)-650W leads by 1,592 places
05
Open the full database
More useful comparisons
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-650W vs Philadelphia Solar PS-MNB156(HCBF)-645W
The same specification on paper
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-650W vs Philadelphia Solar PS-MNB156(HCBF)-640W
3 differences, the largest is module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-650W vs Philadelphia Solar PS-MNB156(HCBF)-635W
3 differences, the largest is module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-650W vs Philadelphia Solar PS-MNB156(HCBF)-630W
3 differences, the largest is module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB144(HCBF)-600W
One difference: module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNG144(HCBF)-600W
3 differences, the largest is weight
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Philadelphia Solar PS-MNB156(HCBF)-650W or Philadelphia Solar PS-MNB144(HCBF)-595W?
According to our database: Philadelphia Solar PS-MNB156(HCBF)-650 W has higher module efficiency (23.26% vs 23.03%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Philadelphia Solar PS-MNB156(HCBF)-650W and Philadelphia Solar PS-MNB144(HCBF)-595W?
Philadelphia Solar PS-MNB156(HCBF)-650 W has a module efficiency of 23.26%, while Philadelphia Solar PS-MNB144(HCBF)-595 W is 23.03%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Philadelphia Solar PS-MNB156(HCBF)-650W use vs Philadelphia Solar PS-MNB144(HCBF)-595W?
Philadelphia Solar PS-MNB156(HCBF)-650 W uses N-type cells; Philadelphia Solar PS-MNB144(HCBF)-595 W uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Philadelphia Solar PS-MNB156(HCBF)-650W and Philadelphia Solar PS-MNB144(HCBF)-595W?
Philadelphia Solar PS-MNB156(HCBF)-650 W has a 30 years power warranty; Philadelphia Solar PS-MNB144(HCBF)-595 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Philadelphia Solar PS-MNB156(HCBF)-650W and Philadelphia Solar PS-MNB144(HCBF)-595W bifacial panels?
Both Philadelphia Solar PS-MNB156(HCBF)-650 W and Philadelphia Solar PS-MNB144(HCBF)-595 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 Philadelphia Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.