Skip to main content
MNB144(HCBF)-595W vs MNG144(HCBF)-600W 16 of 19 identical Swap Change panels

Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNG144(HCBF)-600W

Philadelphia Solar PS-MNB144(HCBF)-595W
Philadelphia Solar
PS-MNB144(HCBF)-595W
595 Wp 23.03 % N-type Bifacial
VS
Philadelphia Solar PS-MNG144(HCBF)-600W
Philadelphia Solar
PS-MNG144(HCBF)-600W
600 Wp 23.22 % N-type Bifacial
The verdict

MNB144(HCBF)-595W leads on the differences that matter

The largest is weight: 5.5 kg lighter. 16 of 19 comparable parameters are identical.

See all 3 differences
How alike are they
16 of 19 comparable
parameters are identical
identical differs
01

What actually differs

3 of 19 parameters
Parameter MNB144(HCBF)-595W MNG144(HCBF)-600W Difference
Weight 27.0 kg 32.5 kg 5.5 kg lighter
Weight per kWp 45.4 kg/kWp 54.2 kg/kWp 8.8 kg/kWp lighter
Dimensions 2278x1134x30 mm 2279x1134x30 mm 2278x1134x30 mm vs 2279x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
MNB144(HCBF)-595W
19,963 kWh
MNG144(HCBF)-600W
20,131 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario MNB144(HCBF)-595W MNG144(HCBF)-600W
Standard test conditions 25 °C 100.0% of rated power 595 W 600 W
Cool, bright day 40 °C 95.7% of rated power 569 W 574 W
Typical summer roof 55 °C 91.3% of rated power 543 W 548 W
Hot roof 70 °C 87.0% of rated power 517 W 522 W
03

Full specification

Parameter MNB144(HCBF)-595W MNG144(HCBF)-600W Difference
Power and efficiency
Rated power 595 Wp 600 Wp Effectively the same
Module efficiency 23.03 % 23.22 % Effectively the same
Power density 230.3 Wp/m² 232.2 Wp/m² Effectively the same
Open-circuit voltage 52.07 V 52.18 V Effectively the same
Voltage at max power 44.34 V 44.58 V Effectively the same
Short-circuit current 14.22 A 14.25 A Effectively the same
Current at max power 13.44 A 13.46 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2278x1134x30 mm 2279x1134x30 mm 2278x1134x30 mm vs 2279x1134x30 mm
Module area 2.583 m² 2.584 m² Effectively the same
Weight 27.0 kg 32.5 kg -5.5 kg for MNB144(HCBF)-595W
Weight per kWp 45.4 kg/kWp 54.2 kg/kWp -8.8 kg/kWp for MNB144(HCBF)-595W
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology N-type N-type Same
Cell type Monocrystalline Monocrystalline Same
Cell count 144 144 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#1,744 vs #1,289
MNG144(HCBF)-600W leads by 455 places
Power density
#1,758 vs #1,332
MNG144(HCBF)-600W leads by 426 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#708 vs #8,370
MNB144(HCBF)-595W leads by 7,662 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#3,213 vs #2,971
MNG144(HCBF)-600W leads by 242 places
05

More useful comparisons

Open the full database
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB156(HCBF)-650W
9 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB156(HCBF)-645W
8 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB156(HCBF)-640W
8 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB156(HCBF)-635W
10 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB156(HCBF)-630W
10 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB144(HCBF)-595W vs Philadelphia Solar PS-MNB144(HCBF)-600W
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Philadelphia Solar PS-MNB144(HCBF)-595W or Philadelphia Solar PS-MNG144(HCBF)-600W?
According to our database: Philadelphia Solar PS-MNG144(HCBF)-600 W has higher module efficiency (23.22% vs 23.03%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Philadelphia Solar PS-MNB144(HCBF)-595W and Philadelphia Solar PS-MNG144(HCBF)-600W?
Philadelphia Solar PS-MNB144(HCBF)-595 W has a module efficiency of 23.03%, while Philadelphia Solar PS-MNG144(HCBF)-600 W is 23.22%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Philadelphia Solar PS-MNB144(HCBF)-595W use vs Philadelphia Solar PS-MNG144(HCBF)-600W?
Philadelphia Solar PS-MNB144(HCBF)-595 W uses N-type cells; Philadelphia Solar PS-MNG144(HCBF)-600 W uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Philadelphia Solar PS-MNB144(HCBF)-595W and Philadelphia Solar PS-MNG144(HCBF)-600W?
Philadelphia Solar PS-MNB144(HCBF)-595 W has a 30 years power warranty; Philadelphia Solar PS-MNG144(HCBF)-600 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Philadelphia Solar PS-MNB144(HCBF)-595W and Philadelphia Solar PS-MNG144(HCBF)-600W bifacial panels?
Both Philadelphia Solar PS-MNB144(HCBF)-595 W and Philadelphia Solar PS-MNG144(HCBF)-600 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 Philadelphia Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.