Skip to main content
MNB156(HCBF)-645W vs MNB108(HCBF)-450W 10 of 19 identical Swap Change panels

Philadelphia Solar PS-MNB156(HCBF)-645W vs Philadelphia Solar PS-MNB108(HCBF)-450W

Philadelphia Solar PS-MNB156(HCBF)-645W
Philadelphia Solar
PS-MNB156(HCBF)-645W
645 Wp 23.08 % N-type Bifacial
VS
Philadelphia Solar PS-MNB108(HCBF)-450W
Philadelphia Solar
PS-MNB108(HCBF)-450W
450 Wp 23.02 % N-type Bifacial
The verdict

MNB108(HCBF)-450W leads on the differences that matter

The largest is rated power: 195 W more power. 10 of 19 comparable parameters are identical.

See all 9 differences
How alike are they
10 of 19 comparable
parameters are identical
identical differs
01

What actually differs

9 of 19 parameters
Parameter MNB156(HCBF)-645W MNB108(HCBF)-450W Difference
Rated power 645 Wp 450 Wp 195 W more power
Weight 32.5 kg 20.5 kg 12.0 kg lighter
Product warranty 12 yrs 25 yrs 13 yrs longer
Open-circuit voltage 56.40 V 38.84 V 17.56 V apart
Module area 2.794 m² 1.955 m² 0.839 m² apart
Weight per kWp 50.4 kg/kWp 45.6 kg/kWp 4.8 kg/kWp lighter
Voltage at max power 48.00 V 33.51 V 14.49 V apart
Cell count 156 108 48 cells apart
Dimensions 2464x1134x35 mm 1724x1134x30 mm 2464x1134x35 mm vs 1724x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
MNB156(HCBF)-645W
21,641 kWh
MNB108(HCBF)-450W
15,098 kWh
Lifetime gap
6,543 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario MNB156(HCBF)-645W MNB108(HCBF)-450W
Standard test conditions 25 °C 100.0% of rated power 645 W 450 W
Cool, bright day 40 °C 95.7% of rated power 617 W 430 W
Typical summer roof 55 °C 91.3% of rated power 589 W 411 W
Hot roof 70 °C 87.0% of rated power 561 W 391 W
03

Full specification

Parameter MNB156(HCBF)-645W MNB108(HCBF)-450W Difference
Power and efficiency
Rated power 645 Wp 450 Wp +195 W for MNB156(HCBF)-645W
Module efficiency 23.08 % 23.02 % Effectively the same
Power density 230.8 Wp/m² 230.2 Wp/m² Effectively the same
Open-circuit voltage 56.40 V 38.84 V 17.56 V apart
Voltage at max power 48.00 V 33.51 V 14.49 V apart
Short-circuit current 14.22 A 14.47 A Effectively the same
Current at max power 13.44 A 13.44 A Same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2464x1134x35 mm 1724x1134x30 mm 2464x1134x35 mm vs 1724x1134x30 mm
Module area 2.794 m² 1.955 m² 0.839 m² apart
Weight 32.5 kg 20.5 kg -12.0 kg for MNB108(HCBF)-450W
Weight per kWp 50.4 kg/kWp 45.6 kg/kWp -4.8 kg/kWp for MNB108(HCBF)-450W
Warranty and degradation
Product warranty 12 yrs 25 yrs +13 yrs for MNB108(HCBF)-450W
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology N-type N-type Same
Cell type Monocrystalline Monocrystalline Same
Cell count 156 108 48 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#1,803 vs #1,924
MNB156(HCBF)-645W leads by 121 places
Power density
#1,773 vs #2,157
MNB156(HCBF)-645W leads by 384 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#3,826 vs #773
MNB108(HCBF)-450W leads by 3,053 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#1,866 vs #5,596
MNB156(HCBF)-645W leads by 3,730 places
05

More useful comparisons

Open the full database
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-645W vs Philadelphia Solar PS-MNB156(HCBF)-650W
The same specification on paper
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-645W vs Philadelphia Solar PS-MNB156(HCBF)-640W
The same specification on paper
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-645W vs Philadelphia Solar PS-MNB156(HCBF)-635W
3 differences, the largest is module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB156(HCBF)-645W vs Philadelphia Solar PS-MNB156(HCBF)-630W
3 differences, the largest is module efficiency
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB108(HCBF)-450W vs Philadelphia Solar PS-MNB144(HCBF)-600W
9 differences, the largest is rated power
Same series, other bin
Philadelphia Solar
Philadelphia Solar PS-MNB108(HCBF)-450W vs Philadelphia Solar PS-MNG144(HCBF)-600W
10 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Philadelphia Solar PS-MNB156(HCBF)-645W or Philadelphia Solar PS-MNB108(HCBF)-450W?
According to our database: Philadelphia Solar PS-MNB156(HCBF)-645 W has higher module efficiency (23.08% vs 23.02%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Philadelphia Solar PS-MNB156(HCBF)-645W and Philadelphia Solar PS-MNB108(HCBF)-450W?
Philadelphia Solar PS-MNB156(HCBF)-645 W has a module efficiency of 23.08%, while Philadelphia Solar PS-MNB108(HCBF)-450 W is 23.02%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Philadelphia Solar PS-MNB156(HCBF)-645W use vs Philadelphia Solar PS-MNB108(HCBF)-450W?
Philadelphia Solar PS-MNB156(HCBF)-645 W uses N-type cells; Philadelphia Solar PS-MNB108(HCBF)-450 W uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Philadelphia Solar PS-MNB156(HCBF)-645W and Philadelphia Solar PS-MNB108(HCBF)-450W?
Philadelphia Solar PS-MNB156(HCBF)-645 W has a 30 years power warranty; Philadelphia Solar PS-MNB108(HCBF)-450 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Philadelphia Solar PS-MNB156(HCBF)-645W and Philadelphia Solar PS-MNB108(HCBF)-450W bifacial panels?
Both Philadelphia Solar PS-MNB156(HCBF)-645 W and Philadelphia Solar PS-MNB108(HCBF)-450 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 3 Philadelphia Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.