Skip to main content
415-R vs 375-BLK 8 of 19 identical Swap Change panels

Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-375-BLK

Maxeon SPR-MAX3-415-R
Maxeon
SPR-MAX3-415-R
415 Wp 21.90 % Back Contact
VS
Maxeon SPR-MAX3-375-BLK
Maxeon
SPR-MAX3-375-BLK
375 Wp 21.20 % Back Contact
The verdict

415-R leads on the differences that matter

The largest is module efficiency: 0.70 pp more efficient. 8 of 19 comparable parameters are identical.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs
01

What actually differs

11 of 19 parameters
Parameter 415-R 375-BLK Difference
Module efficiency 21.90 % 21.20 % 0.70 pp more efficient
Rated power 415 Wp 375 Wp 40 W more power
Power density 219.0 Wp/m² 212.1 Wp/m² 6.8 Wp/m² higher
Open-circuit voltage 40.60 V 75.50 V 34.90 V apart
Short-circuit current 13.10 A 6.30 A 6.80 A apart
Module area 1.895 m² 1.768 m² 0.128 m² apart
Weight 21.2 kg 19.0 kg 2.2 kg lighter
Voltage at max power 34.50 V 64.00 V 29.50 V apart
Current at max power 12.03 A 5.86 A 6.17 A apart
Cell count 112 104 8 cells apart
Dimensions 1812x1046x40 mm 1690x1046x40 mm 1812x1046x40 mm vs 1690x1046x40 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.270 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
415-R
14,100 kWh
375-BLK
12,741 kWh
Lifetime gap
1,359 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 415-R 375-BLK
Standard test conditions 25 °C 100.0% of rated power 415 W 375 W
Cool, bright day 40 °C 96.0% of rated power 398 W 360 W
Typical summer roof 55 °C 91.9% of rated power 381 W 345 W
Hot roof 70 °C 87.8% of rated power 365 W 329 W
03

Full specification

Parameter 415-R 375-BLK Difference
Power and efficiency
Rated power 415 Wp 375 Wp +40 W for 415-R
Module efficiency 21.90 % 21.20 % +0.70 pp for 415-R
Power density 219.0 Wp/m² 212.1 Wp/m² +6.8 Wp/m² for 415-R
Open-circuit voltage 40.60 V 75.50 V 34.90 V apart
Voltage at max power 34.50 V 64.00 V 29.50 V apart
Short-circuit current 13.10 A 6.30 A 6.80 A apart
Current at max power 12.03 A 5.86 A 6.17 A apart
Temperature
Temperature coefficient -0.270 %/°C -0.270 %/°C Same
Mechanical
Dimensions 1812x1046x40 mm 1690x1046x40 mm 1812x1046x40 mm vs 1690x1046x40 mm
Module area 1.895 m² 1.768 m² 0.128 m² apart
Weight 21.2 kg 19.0 kg -2.2 kg for 375-BLK
Weight per kWp 51.1 kg/kWp 50.7 kg/kWp Effectively the same
Warranty and degradation
Product warranty 40 yrs 40 yrs Same
Performance warranty 40 yrs 40 yrs Same
Annual degradation 0.25 %/yr 0.25 %/yr Same
Technology
Cell technology Back Contact Back Contact Same
Cell type Monocrystalline Monocrystalline Same
Cell count 112 104 8 cells apart
Bifacial No No Same
04

Against the whole database

14,005 panels
Efficiency
#6,783 vs #9,076
415-R leads by 2,293 places
Power density
#6,789 vs #9,087
415-R leads by 2,298 places
Heat behaviour
#1,280 vs #1,280
Tied - the same position in the database
Weight
#4,418 vs #4,094
375-BLK leads by 324 places
Warranty
#1 vs #1
Tied - the same position in the database
Overall
#2,872 vs #5,002
415-R leads by 2,130 places
05

More useful comparisons

Open the full database
Same series, other bin
Maxeon
Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-430-R
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-425-R
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-400-COM
12 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-390-COM
11 differences, the largest is rated power
Same series, other bin
Maxeon
Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-380-COM
11 differences, the largest is rated power
Same series, other bin
Maxeon
Maxeon SPR-MAX3-415-R vs Maxeon SPR-MAX3-370-COM
13 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Maxeon SPR-MAX3-415-R or Maxeon SPR-MAX3-375-BLK?
According to our database: Maxeon SPR-MAX3-415-R has higher module efficiency (21.90% vs 21.20%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Maxeon SPR-MAX3-415-R and Maxeon SPR-MAX3-375-BLK?
Maxeon SPR-MAX3-415-R has a module efficiency of 21.90%, while Maxeon SPR-MAX3-375-BLK is 21.20%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Maxeon SPR-MAX3-415-R use vs Maxeon SPR-MAX3-375-BLK?
Maxeon SPR-MAX3-415-R uses Back Contact cells; Maxeon SPR-MAX3-375-BLK uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Maxeon SPR-MAX3-415-R and Maxeon SPR-MAX3-375-BLK?
Maxeon SPR-MAX3-415-R has a 40 years power warranty; Maxeon SPR-MAX3-375-BLK has a 40 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 26 Maxeon offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.