Skip to main content
375-BLK vs 415-R 8 of 19 identical Swap Change panels

Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-415-R

Maxeon SPR-MAX3-375-BLK
Maxeon
SPR-MAX3-375-BLK
375 Wp 21.20 % Back Contact
VS
Maxeon SPR-MAX3-415-R
Maxeon
SPR-MAX3-415-R
415 Wp 21.90 % Back Contact
The verdict

415-R leads on the differences that matter

The largest is module efficiency: 0.70 pp more efficient. 8 of 19 comparable parameters are identical.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs
01

What actually differs

11 of 19 parameters
Parameter 375-BLK 415-R Difference
Module efficiency 21.20 % 21.90 % 0.70 pp more efficient
Rated power 375 Wp 415 Wp 40 W more power
Power density 212.1 Wp/m² 219.0 Wp/m² 6.8 Wp/m² higher
Open-circuit voltage 75.50 V 40.60 V 34.90 V apart
Short-circuit current 6.30 A 13.10 A 6.80 A apart
Module area 1.768 m² 1.895 m² 0.128 m² apart
Weight 19.0 kg 21.2 kg 2.2 kg lighter
Voltage at max power 64.00 V 34.50 V 29.50 V apart
Current at max power 5.86 A 12.03 A 6.17 A apart
Cell count 104 112 8 cells apart
Dimensions 1690x1046x40 mm 1812x1046x40 mm 1690x1046x40 mm vs 1812x1046x40 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.270 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
375-BLK
12,741 kWh
415-R
14,100 kWh
Lifetime gap
1,359 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 375-BLK 415-R
Standard test conditions 25 °C 100.0% of rated power 375 W 415 W
Cool, bright day 40 °C 96.0% of rated power 360 W 398 W
Typical summer roof 55 °C 91.9% of rated power 345 W 381 W
Hot roof 70 °C 87.8% of rated power 329 W 365 W
03

Full specification

Parameter 375-BLK 415-R Difference
Power and efficiency
Rated power 375 Wp 415 Wp +40 W for 415-R
Module efficiency 21.20 % 21.90 % +0.70 pp for 415-R
Power density 212.1 Wp/m² 219.0 Wp/m² +6.8 Wp/m² for 415-R
Open-circuit voltage 75.50 V 40.60 V 34.90 V apart
Voltage at max power 64.00 V 34.50 V 29.50 V apart
Short-circuit current 6.30 A 13.10 A 6.80 A apart
Current at max power 5.86 A 12.03 A 6.17 A apart
Temperature
Temperature coefficient -0.270 %/°C -0.270 %/°C Same
Mechanical
Dimensions 1690x1046x40 mm 1812x1046x40 mm 1690x1046x40 mm vs 1812x1046x40 mm
Module area 1.768 m² 1.895 m² 0.128 m² apart
Weight 19.0 kg 21.2 kg -2.2 kg for 375-BLK
Weight per kWp 50.7 kg/kWp 51.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 40 yrs 40 yrs Same
Performance warranty 40 yrs 40 yrs Same
Annual degradation 0.25 %/yr 0.25 %/yr Same
Technology
Cell technology Back Contact Back Contact Same
Cell type Monocrystalline Monocrystalline Same
Cell count 104 112 8 cells apart
Bifacial No No Same
04

Against the whole database

14,005 panels
Efficiency
#9,076 vs #6,783
415-R leads by 2,293 places
Power density
#9,087 vs #6,789
415-R leads by 2,298 places
Heat behaviour
#1,280 vs #1,280
Tied - the same position in the database
Weight
#4,094 vs #4,418
375-BLK leads by 324 places
Warranty
#1 vs #1
Tied - the same position in the database
Overall
#5,002 vs #2,872
415-R leads by 2,130 places
05

More useful comparisons

Open the full database
Same series, other bin
Maxeon
Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-430-R
11 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-425-R
11 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-400-COM
5 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-390-COM
3 differences, the largest is module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-380-COM
One difference: module efficiency
Same series, other bin
Maxeon
Maxeon SPR-MAX3-375-BLK vs Maxeon SPR-MAX3-370-COM
4 differences, the largest is performance warranty
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Maxeon SPR-MAX3-375-BLK or Maxeon SPR-MAX3-415-R?
According to our database: Maxeon SPR-MAX3-415-R has higher module efficiency (21.90% vs 21.20%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Maxeon SPR-MAX3-375-BLK and Maxeon SPR-MAX3-415-R?
Maxeon SPR-MAX3-375-BLK has a module efficiency of 21.20%, while Maxeon SPR-MAX3-415-R is 21.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Maxeon SPR-MAX3-375-BLK use vs Maxeon SPR-MAX3-415-R?
Maxeon SPR-MAX3-375-BLK uses Back Contact cells; Maxeon SPR-MAX3-415-R uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Maxeon SPR-MAX3-375-BLK and Maxeon SPR-MAX3-415-R?
Maxeon SPR-MAX3-375-BLK has a 40 years power warranty; Maxeon SPR-MAX3-415-R has a 40 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 26 Maxeon offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.