GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/48BGDF-440
VS
The verdict
NT12R/54BGDF-505W leads on the differences that matter
The largest is module efficiency: 0.68 pp more efficient. 9 of 19 comparable parameters are identical.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
10 of 19 parameters
What actually differs
Parameter
NT12R/54BGDF-505W
GCL-NT12R/48BGDF-440
Difference
Module efficiency
22.70 %
22.02 %
0.68 pp more efficient
Rated power
505 Wp
440 Wp
65 W more power
Weight
27.3 kg
21.5 kg
5.8 kg lighter
Power density
227.0 Wp/m²
220.2 Wp/m²
6.8 Wp/m² higher
Open-circuit voltage
40.61 V
35.38 V
5.23 V apart
Module area
2.225 m²
1.998 m²
0.227 m² apart
Weight per kWp
54.1 kg/kWp
48.9 kg/kWp
5.2 kg/kWp lighter
Voltage at max power
34.22 V
29.85 V
4.37 V apart
Cell count
108
96
12 cells apart
Dimensions
1962x1134x30 mm
1762x1134x30 mm
1962x1134x30 mm vs 1762x1134x30 mm
02
What it means on a roof
Thirty years of production
Declared annual degradation, with a 1.0% first-year loss assumed for both panels because at least one datasheet omits it, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
NT12R/54BGDF-505W
16,944 kWh
GCL-NT12R/48BGDF-440
14,763 kWh
Lifetime gap
2,181 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
NT12R/54BGDF-505W
GCL-NT12R/48BGDF-440
Standard test conditions
25 °C
100.0% of rated power
505 W
440 W
Cool, bright day
40 °C
95.7% of rated power
483 W
421 W
Typical summer roof
55 °C
91.3% of rated power
461 W
402 W
Hot roof
70 °C
87.0% of rated power
439 W
383 W
03
Full specification
Parameter
NT12R/54BGDF-505W
GCL-NT12R/48BGDF-440
Difference
Power and efficiency
Rated power
505 Wp
440 Wp
+65 W for NT12R/54BGDF-505W
Module efficiency
22.70 %
22.02 %
+0.68 pp for NT12R/54BGDF-505W
Power density
227.0 Wp/m²
220.2 Wp/m²
+6.8 Wp/m² for NT12R/54BGDF-505W
Open-circuit voltage
40.61 V
35.38 V
5.23 V apart
Voltage at max power
34.22 V
29.85 V
4.37 V apart
Short-circuit current
15.44 A
15.48 A
Effectively the same
Current at max power
14.76 A
14.74 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1962x1134x30 mm
1762x1134x30 mm
1962x1134x30 mm vs 1762x1134x30 mm
Module area
2.225 m²
1.998 m²
0.227 m² apart
Weight
27.3 kg
21.5 kg
-5.8 kg for GCL-NT12R/48BGDF-440
Weight per kWp
54.1 kg/kWp
48.9 kg/kWp
-5.2 kg/kWp for GCL-NT12R/48BGDF-440
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
96
12 cells apart
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#3,470
vs
#6,524
NT12R/54BGDF-505W leads by 3,054 places
Power density
#3,516
vs
#6,524
NT12R/54BGDF-505W leads by 3,008 places
Heat behaviour
#2,288
vs
#2,288
Tied - the same position in the database
Weight
#8,468
vs
#2,558
GCL-NT12R/48BGDF-440 leads by 5,910 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#7,053
vs
#9,959
NT12R/54BGDF-505W leads by 2,906 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/54GDF-530
6 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL NT12R/54GDF-525W
6 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/54GDF-525
6 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL NT12R/54BGDF-520W
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL NT12R/54GDF-520W
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/54GDF-520
5 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL NT12R/54BGDF-505W or GCL GCL-NT12R/48BGDF-440?
According to our database: GCL NT12R/54BGDF-505 W has higher module efficiency (22.70% vs 22.02%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/54BGDF-505W and GCL GCL-NT12R/48BGDF-440?
GCL NT12R/54BGDF-505 W has a module efficiency of 22.70%, while GCL GCL-NT12R/48BGDF-440 is 22.02%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/54BGDF-505W use vs GCL GCL-NT12R/48BGDF-440?
GCL NT12R/54BGDF-505 W uses TOPCon cells; GCL GCL-NT12R/48BGDF-440 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/54BGDF-505W and GCL GCL-NT12R/48BGDF-440?
GCL NT12R/54BGDF-505 W has a 30 years power warranty; GCL GCL-NT12R/48BGDF-440 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/54BGDF-505W and GCL GCL-NT12R/48BGDF-440 bifacial panels?
Both GCL NT12R/54BGDF-505 W and GCL GCL-NT12R/48BGDF-440 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 3 GCL offers