GCL NT12R/54BGDF-505W vs GCL NT12R/54GDF-525W
VS
The verdict
54GDF-525W leads on the differences that matter
The largest is module efficiency: 0.90 pp more efficient. 13 of 19 comparable parameters are identical.
See all 6 differencesHow alike are they
13
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
6 of 19 parameters
What actually differs
Parameter
54BGDF-505W
54GDF-525W
Difference
Module efficiency
22.70 %
23.60 %
0.90 pp more efficient
Power density
227.0 Wp/m²
236.0 Wp/m²
9.0 Wp/m² higher
Rated power
505 Wp
525 Wp
20 W more power
Weight per kWp
54.1 kg/kWp
52.0 kg/kWp
2.1 kg/kWp lighter
Short-circuit current
15.44 A
16.16 A
0.72 A apart
Current at max power
14.76 A
15.35 A
0.59 A apart
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
54BGDF-505W
16,944 kWh
54GDF-525W
17,615 kWh
Lifetime gap
671 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
54BGDF-505W
54GDF-525W
Standard test conditions
25 °C
100.0% of rated power
505 W
525 W
Cool, bright day
40 °C
95.7% of rated power
483 W
502 W
Typical summer roof
55 °C
91.3% of rated power
461 W
479 W
Hot roof
70 °C
87.0% of rated power
439 W
456 W
03
Full specification
Parameter
54BGDF-505W
54GDF-525W
Difference
Power and efficiency
Rated power
505 Wp
525 Wp
+20 W for 54GDF-525W
Module efficiency
22.70 %
23.60 %
+0.90 pp for 54GDF-525W
Power density
227.0 Wp/m²
236.0 Wp/m²
+9.0 Wp/m² for 54GDF-525W
Open-circuit voltage
40.61 V
40.30 V
Effectively the same
Voltage at max power
34.22 V
34.20 V
Effectively the same
Short-circuit current
15.44 A
16.16 A
0.72 A apart
Current at max power
14.76 A
15.35 A
0.59 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1962x1134x30 mm
1962x1134x30 mm
Same
Module area
2.225 m²
2.225 m²
Same
Weight
27.3 kg
27.3 kg
Same
Weight per kWp
54.1 kg/kWp
52.0 kg/kWp
-2.1 kg/kWp for 54GDF-525W
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#3,307
vs
#627
54GDF-525W leads by 2,680 places
Power density
#3,353
vs
#653
54GDF-525W leads by 2,700 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#8,277
vs
#5,417
54GDF-525W leads by 2,860 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#6,858
vs
#5,035
54GDF-525W leads by 1,823 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/54GDF-530
6 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/54GDF-525
6 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL NT12R/54BGDF-520W
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL NT12R/54GDF-520W
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL GCL-NT12R/54GDF-520
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-505W vs GCL NT12R/54BGDF-515W
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL NT12R/54BGDF-505W or GCL NT12R/54GDF-525W?
According to our database: GCL NT12R/54GDF-525 W has higher module efficiency (23.60% vs 22.70%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/54BGDF-505W and GCL NT12R/54GDF-525W?
GCL NT12R/54BGDF-505 W has a module efficiency of 22.70%, while GCL NT12R/54GDF-525 W is 23.60%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/54BGDF-505W use vs GCL NT12R/54GDF-525W?
GCL NT12R/54BGDF-505 W uses TOPCon cells; GCL NT12R/54GDF-525 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/54BGDF-505W and GCL NT12R/54GDF-525W?
GCL NT12R/54BGDF-505 W has a 30 years power warranty; GCL NT12R/54GDF-525 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/54BGDF-505W and GCL NT12R/54GDF-525W bifacial panels?
Both GCL NT12R/54BGDF-505 W and GCL NT12R/54GDF-525 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 6 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.