Skip to main content
FU455MV Silk Rhino vs FU450MV Silk Rhino 18 of 19 identical Swap Change panels

FuturaSun FU455MV Silk Rhino vs FuturaSun FU450MV Silk Rhino

FuturaSun FU455MV Silk Rhino
FuturaSun
FU455MV Silk Rhino
455 Wp 22.77 % TOPCon
VS
FuturaSun FU450MV Silk Rhino
FuturaSun
FU450MV Silk Rhino
450 Wp 22.52 % TOPCon
The verdict

FU455MV Silk Rhino leads on the differences that matter

The largest is module efficiency: 0.25 pp more efficient. 18 of 19 comparable parameters are identical.

See the one difference
How alike are they
18 of 19 comparable
parameters are identical
identical differs
01

What actually differs

1 of 19 parameters
Parameter FU455MV Silk Rhino FU450MV Silk Rhino Difference
Module efficiency 22.77 % 22.52 % 0.25 pp more efficient
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
FU455MV Silk Rhino
15,266 kWh
FU450MV Silk Rhino
15,098 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario FU455MV Silk Rhino FU450MV Silk Rhino
Standard test conditions 25 °C 100.0% of rated power 455 W 450 W
Cool, bright day 40 °C 95.7% of rated power 435 W 430 W
Typical summer roof 55 °C 91.3% of rated power 415 W 411 W
Hot roof 70 °C 87.0% of rated power 396 W 391 W
03

Full specification

Parameter FU455MV Silk Rhino FU450MV Silk Rhino Difference
Power and efficiency
Rated power 455 Wp 450 Wp Effectively the same
Module efficiency 22.77 % 22.52 % +0.25 pp for FU455MV Silk Rhino
Power density 227.7 Wp/m² 225.2 Wp/m² Effectively the same
Open-circuit voltage 35.63 V 35.47 V Effectively the same
Voltage at max power 30.17 V 30.01 V Effectively the same
Short-circuit current 16.02 A 15.97 A Effectively the same
Current at max power 15.08 A 15.00 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 26.6 kg 26.6 kg Same
Weight per kWp 58.5 kg/kWp 59.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 25 yrs 25 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 96 Same
Bifacial No No Same
04

Against the whole database

14,354 panels
Efficiency
#3,232 vs #4,277
FU455MV Silk Rhino leads by 1,045 places
Power density
#3,046 vs #4,400
FU455MV Silk Rhino leads by 1,354 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#11,993 vs #12,296
FU455MV Silk Rhino leads by 303 places
Warranty
#10,073 vs #10,073
Tied - the same position in the database
Overall
#9,330 vs #9,721
FU455MV Silk Rhino leads by 391 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 455 M Silk Rhino
One difference: cell technology
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 450 M Silk Rhino
2 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 450 M Silk Rhino All Black
2 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU445MV Silk Rhino
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 445 M Silk Rhino
4 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 445 M Silk Rhino All Black
4 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU455MV Silk Rhino or FuturaSun FU450MV Silk Rhino?
According to our database: FuturaSun FU455MV Silk Rhino has higher module efficiency (22.77% vs 22.52%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU455MV Silk Rhino and FuturaSun FU450MV Silk Rhino?
FuturaSun FU455MV Silk Rhino has a module efficiency of 22.77%, while FuturaSun FU450MV Silk Rhino is 22.52%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU455MV Silk Rhino use vs FuturaSun FU450MV Silk Rhino?
FuturaSun FU455MV Silk Rhino uses TOPCon cells; FuturaSun FU450MV Silk Rhino uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU455MV Silk Rhino and FuturaSun FU450MV Silk Rhino?
FuturaSun FU455MV Silk Rhino has a 25 years power warranty; FuturaSun FU450MV Silk Rhino has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.