Skip to main content
FU455MV Silk Rhino vs FU 450 M Silk Rhino All Black 17 of 19 identical Swap Change panels

FuturaSun FU455MV Silk Rhino vs FuturaSun FU 450 M Silk Rhino All Black

FuturaSun FU455MV Silk Rhino
FuturaSun
FU455MV Silk Rhino
455 Wp 22.77 % TOPCon
VS
FuturaSun FU 450 M Silk Rhino All Black
FuturaSun
FU 450 M Silk Rhino All Black
450 Wp 22.52 % N-type
The verdict

FU455MV Silk Rhino leads on the differences that matter

The largest is module efficiency: 0.25 pp more efficient. 17 of 19 comparable parameters are identical.

See all 2 differences
How alike are they
17 of 19 comparable
parameters are identical
identical differs
01

What actually differs

2 of 19 parameters
Parameter FU455MV Silk Rhino FU 450 M Silk Rhino All Black Difference
Module efficiency 22.77 % 22.52 % 0.25 pp more efficient
Cell technology TOPCon N-type TOPCon vs N-type
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
FU455MV Silk Rhino
15,266 kWh
FU 450 M Silk Rhino All Black
15,098 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario FU455MV Silk Rhino FU 450 M Silk Rhino All Black
Standard test conditions 25 °C 100.0% of rated power 455 W 450 W
Cool, bright day 40 °C 95.7% of rated power 435 W 430 W
Typical summer roof 55 °C 91.3% of rated power 415 W 411 W
Hot roof 70 °C 87.0% of rated power 396 W 391 W
03

Full specification

Parameter FU455MV Silk Rhino FU 450 M Silk Rhino All Black Difference
Power and efficiency
Rated power 455 Wp 450 Wp Effectively the same
Module efficiency 22.77 % 22.52 % +0.25 pp for FU455MV Silk Rhino
Power density 227.7 Wp/m² 225.2 Wp/m² Effectively the same
Open-circuit voltage 35.63 V 35.47 V Effectively the same
Voltage at max power 30.17 V 30.01 V Effectively the same
Short-circuit current 16.02 A 15.97 A Effectively the same
Current at max power 15.08 A 15.00 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 26.6 kg 26.6 kg Same
Weight per kWp 58.5 kg/kWp 59.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 25 yrs 25 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon N-type TOPCon vs N-type
Cell type Monocrystalline Monocrystalline Same
Cell count 96 96 Same
Bifacial No No Same
04

Against the whole database

14,354 panels
Efficiency
#3,232 vs #4,277
FU455MV Silk Rhino leads by 1,045 places
Power density
#3,046 vs #4,400
FU455MV Silk Rhino leads by 1,354 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#11,993 vs #12,296
FU455MV Silk Rhino leads by 303 places
Warranty
#10,073 vs #10,073
Tied - the same position in the database
Overall
#9,330 vs #9,721
FU455MV Silk Rhino leads by 391 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 455 M Silk Rhino
One difference: cell technology
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU450MV Silk Rhino
One difference: module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 450 M Silk Rhino
2 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU445MV Silk Rhino
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 445 M Silk Rhino
4 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU455MV Silk Rhino vs FuturaSun FU 445 M Silk Rhino All Black
4 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU455MV Silk Rhino or FuturaSun FU 450 M Silk Rhino All Black?
According to our database: FuturaSun FU455MV Silk Rhino has higher module efficiency (22.77% vs 22.52%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU455MV Silk Rhino and FuturaSun FU 450 M Silk Rhino All Black?
FuturaSun FU455MV Silk Rhino has a module efficiency of 22.77%, while FuturaSun FU 450 M Silk Rhino All Black is 22.52%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU455MV Silk Rhino use vs FuturaSun FU 450 M Silk Rhino All Black?
FuturaSun FU455MV Silk Rhino uses TOPCon cells; FuturaSun FU 450 M Silk Rhino All Black uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU455MV Silk Rhino and FuturaSun FU 450 M Silk Rhino All Black?
FuturaSun FU455MV Silk Rhino has a 25 years power warranty; FuturaSun FU 450 M Silk Rhino All Black has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.