Skip to main content
FU450MV Silk Rhino vs FU445MV Silk Rhino 18 of 19 identical Swap Change panels

FuturaSun FU450MV Silk Rhino vs FuturaSun FU445MV Silk Rhino

FuturaSun FU450MV Silk Rhino
FuturaSun
FU450MV Silk Rhino
450 Wp 22.52 % TOPCon
VS
FuturaSun FU445MV Silk Rhino
FuturaSun
FU445MV Silk Rhino
445 Wp 22.27 % TOPCon
The verdict

FU450MV Silk Rhino leads on the differences that matter

The largest is module efficiency: 0.25 pp more efficient. 18 of 19 comparable parameters are identical.

See the one difference
How alike are they
18 of 19 comparable
parameters are identical
identical differs
01

What actually differs

1 of 19 parameters
Parameter FU450MV Silk Rhino FU445MV Silk Rhino Difference
Module efficiency 22.52 % 22.27 % 0.25 pp more efficient
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
FU450MV Silk Rhino
15,098 kWh
FU445MV Silk Rhino
14,931 kWh
Lifetime gap
167 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario FU450MV Silk Rhino FU445MV Silk Rhino
Standard test conditions 25 °C 100.0% of rated power 450 W 445 W
Cool, bright day 40 °C 95.7% of rated power 430 W 426 W
Typical summer roof 55 °C 91.3% of rated power 411 W 406 W
Hot roof 70 °C 87.0% of rated power 391 W 387 W
03

Full specification

Parameter FU450MV Silk Rhino FU445MV Silk Rhino Difference
Power and efficiency
Rated power 450 Wp 445 Wp Effectively the same
Module efficiency 22.52 % 22.27 % +0.25 pp for FU450MV Silk Rhino
Power density 225.2 Wp/m² 222.7 Wp/m² Effectively the same
Open-circuit voltage 35.47 V 35.30 V Effectively the same
Voltage at max power 30.01 V 29.81 V Effectively the same
Short-circuit current 15.97 A 15.91 A Effectively the same
Current at max power 15.00 A 14.93 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 26.6 kg 26.6 kg Same
Weight per kWp 59.1 kg/kWp 59.8 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 25 yrs 25 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 96 Same
Bifacial No No Same
04

Against the whole database

14,354 panels
Efficiency
#4,277 vs #5,669
FU450MV Silk Rhino leads by 1,392 places
Power density
#4,400 vs #5,490
FU450MV Silk Rhino leads by 1,090 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#12,296 vs #12,543
FU450MV Silk Rhino leads by 247 places
Warranty
#10,073 vs #10,073
Tied - the same position in the database
Overall
#9,721 vs #10,070
FU450MV Silk Rhino leads by 349 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU450MV Silk Rhino vs FuturaSun FU455MV Silk Rhino
One difference: module efficiency
Same series, other bin
FuturaSun
FuturaSun FU450MV Silk Rhino vs FuturaSun FU 455 M Silk Rhino
2 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU450MV Silk Rhino vs FuturaSun FU 450 M Silk Rhino
One difference: cell technology
Same series, other bin
FuturaSun
FuturaSun FU450MV Silk Rhino vs FuturaSun FU 450 M Silk Rhino All Black
One difference: cell technology
Same series, other bin
FuturaSun
FuturaSun FU450MV Silk Rhino vs FuturaSun FU 445 M Silk Rhino
2 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU450MV Silk Rhino vs FuturaSun FU 445 M Silk Rhino All Black
2 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU450MV Silk Rhino or FuturaSun FU445MV Silk Rhino?
According to our database: FuturaSun FU450MV Silk Rhino has higher module efficiency (22.52% vs 22.27%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU450MV Silk Rhino and FuturaSun FU445MV Silk Rhino?
FuturaSun FU450MV Silk Rhino has a module efficiency of 22.52%, while FuturaSun FU445MV Silk Rhino is 22.27%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU450MV Silk Rhino use vs FuturaSun FU445MV Silk Rhino?
FuturaSun FU450MV Silk Rhino uses TOPCon cells; FuturaSun FU445MV Silk Rhino uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU450MV Silk Rhino and FuturaSun FU445MV Silk Rhino?
FuturaSun FU450MV Silk Rhino has a 25 years power warranty; FuturaSun FU445MV Silk Rhino has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.