FuturaSun FU 710 MV vs FuturaSun FU 425 M Silk Rhino All Black
VS
The verdict
710 MV leads on the differences that matter
The largest is module efficiency: 1.06 pp more efficient. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
710 MV
425 M Silk Rhino All Black
Difference
Module efficiency
22.86 %
21.80 %
1.06 pp more efficient
Rated power
710 Wp
425 Wp
285 W more power
Performance warranty
30 yrs
25 yrs
5 yrs longer
Power density
228.6 Wp/m²
217.6 Wp/m²
10.9 Wp/m² higher
Weight
38.2 kg
26.0 kg
12.2 kg lighter
Weight per kWp
53.8 kg/kWp
61.2 kg/kWp
7.4 kg/kWp lighter
Open-circuit voltage
48.66 V
38.25 V
10.41 V apart
Short-circuit current
18.46 A
14.17 A
4.29 A apart
Module area
3.106 m²
1.953 m²
1.154 m² apart
Cell technology
TOPCon
N-type
TOPCon vs N-type
Voltage at max power
40.89 V
31.67 V
9.22 V apart
Current at max power
17.37 A
13.42 A
3.95 A apart
Cell count
132
108
24 cells apart
Bifacial
Yes
No
Yes vs No
Dimensions
2384x1303x33 mm
1722x1134x30 mm
2384x1303x33 mm vs 1722x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
710 MV
23,822 kWh
425 M Silk Rhino All Black
14,260 kWh
Lifetime gap
9,562 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
710 MV
425 M Silk Rhino All Black
Standard test conditions
25 °C
100.0% of rated power
710 W
425 W
Cool, bright day
40 °C
95.7% of rated power
679 W
407 W
Typical summer roof
55 °C
91.3% of rated power
648 W
388 W
Hot roof
70 °C
87.0% of rated power
617 W
370 W
03
Full specification
Parameter
710 MV
425 M Silk Rhino All Black
Difference
Power and efficiency
Rated power
710 Wp
425 Wp
+285 W for 710 MV
Module efficiency
22.86 %
21.80 %
+1.06 pp for 710 MV
Power density
228.6 Wp/m²
217.6 Wp/m²
+10.9 Wp/m² for 710 MV
Open-circuit voltage
48.66 V
38.25 V
10.41 V apart
Voltage at max power
40.89 V
31.67 V
9.22 V apart
Short-circuit current
18.46 A
14.17 A
4.29 A apart
Current at max power
17.37 A
13.42 A
3.95 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
2384x1303x33 mm
1722x1134x30 mm
2384x1303x33 mm vs 1722x1134x30 mm
Module area
3.106 m²
1.953 m²
1.154 m² apart
Weight
38.2 kg
26.0 kg
-12.2 kg for 425 M Silk Rhino All Black
Weight per kWp
53.8 kg/kWp
61.2 kg/kWp
-7.4 kg/kWp for 710 MV
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
30 yrs
25 yrs
+5 yrs for 710 MV
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
N-type
TOPCon vs N-type
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
132
108
24 cells apart
Bifacial
Yes
No
Yes vs No
04
14,354 panels
Against the whole database
Efficiency
#2,686
vs
#7,225
710 MV leads by 4,539 places
Power density
#2,624
vs
#7,375
710 MV leads by 4,751 places
Heat behaviour
#2,288
vs
#2,288
Tied - the same position in the database
Weight
#8,069
vs
#12,901
710 MV leads by 4,832 places
Warranty
#31
vs
#10,073
710 MV leads by 10,042 places
Overall
#639
vs
#10,867
710 MV leads by 10,228 places
05
Open the full database
More useful comparisons
Same series, other bin
FuturaSun
FuturaSun FU 710 MV vs FuturaSun FU 720 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 710 MV vs FuturaSun FU 700 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 450 M Silk Rhino All Black
11 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 445 M Silk Rhino All Black
10 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 440 M Silk Rhino All Black
9 differences, the largest is short-circuit current
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 430 M Silk Rhino All Black
One difference: module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: FuturaSun FU 710 MV or FuturaSun FU 425 M Silk Rhino All Black?
According to our database: FuturaSun FU 710 MV has higher module efficiency (22.86% vs 21.80%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 710 MV and FuturaSun FU 425 M Silk Rhino All Black?
FuturaSun FU 710 MV has a module efficiency of 22.86%, while FuturaSun FU 425 M Silk Rhino All Black is 21.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 710 MV use vs FuturaSun FU 425 M Silk Rhino All Black?
FuturaSun FU 710 MV uses TOPCon cells; FuturaSun FU 425 M Silk Rhino All Black uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 710 MV and FuturaSun FU 425 M Silk Rhino All Black?
FuturaSun FU 710 MV has a 30 years power warranty; FuturaSun FU 425 M Silk Rhino All Black has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 710 MV and FuturaSun FU 425 M Silk Rhino All Black bifacial panels?
FuturaSun FU 710 MV is bifacial (captures light from both faces); FuturaSun FU 425 M Silk Rhino All Black is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 8 FuturaSun offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.
