Skip to main content
425 M Silk Rhino All Black vs 440 M Silk Rhino All Black 10 of 19 identical Swap Change panels

FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 440 M Silk Rhino All Black

FuturaSun FU 425 M Silk Rhino All Black
FuturaSun
FU 425 M Silk Rhino All Black
425 Wp 21.80 % N-type
VS
FuturaSun FU 440 M Silk Rhino All Black
FuturaSun
FU 440 M Silk Rhino All Black
440 Wp 22.02 % N-type
The verdict

440 M Silk Rhino All Black leads on the differences that matter

The largest is short-circuit current: 1.68 A apart. 10 of 19 comparable parameters are identical.

See all 9 differences
How alike are they
10 of 19 comparable
parameters are identical
identical differs
01

What actually differs

9 of 19 parameters
Parameter 425 M Silk Rhino All Black 440 M Silk Rhino All Black Difference
Short-circuit current 14.17 A 15.85 A 1.68 A apart
Open-circuit voltage 38.25 V 35.14 V 3.11 V apart
Rated power 425 Wp 440 Wp 15 W more power
Module efficiency 21.80 % 22.02 % 0.22 pp more efficient
Module area 1.953 m² 1.998 m² 0.045 m² apart
Cell count 108 96 12 cells apart
Current at max power 13.42 A 14.86 A 1.44 A apart
Voltage at max power 31.67 V 29.62 V 2.05 V apart
Dimensions 1722x1134x30 mm 1762x1134x30 mm 1722x1134x30 mm vs 1762x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
425 M Silk Rhino All Black
14,260 kWh
440 M Silk Rhino All Black
14,763 kWh
Lifetime gap
503 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 425 M Silk Rhino All Black 440 M Silk Rhino All Black
Standard test conditions 25 °C 100.0% of rated power 425 W 440 W
Cool, bright day 40 °C 95.7% of rated power 407 W 421 W
Typical summer roof 55 °C 91.3% of rated power 388 W 402 W
Hot roof 70 °C 87.0% of rated power 370 W 383 W
03

Full specification

Parameter 425 M Silk Rhino All Black 440 M Silk Rhino All Black Difference
Power and efficiency
Rated power 425 Wp 440 Wp +15 W for 440 M Silk Rhino All Black
Module efficiency 21.80 % 22.02 % +0.22 pp for 440 M Silk Rhino All Black
Power density 217.6 Wp/m² 220.2 Wp/m² Effectively the same
Open-circuit voltage 38.25 V 35.14 V 3.11 V apart
Voltage at max power 31.67 V 29.62 V 2.05 V apart
Short-circuit current 14.17 A 15.85 A 1.68 A apart
Current at max power 13.42 A 14.86 A 1.44 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1722x1134x30 mm 1762x1134x30 mm 1722x1134x30 mm vs 1762x1134x30 mm
Module area 1.953 m² 1.998 m² 0.045 m² apart
Weight 26.0 kg 26.6 kg Effectively the same
Weight per kWp 61.2 kg/kWp 60.5 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 25 yrs 25 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology N-type N-type Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 96 12 cells apart
Bifacial No No Same
04

Against the whole database

14,354 panels
Efficiency
#7,225 vs #6,524
440 M Silk Rhino All Black leads by 701 places
Power density
#7,375 vs #6,524
440 M Silk Rhino All Black leads by 851 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#12,901 vs #12,750
440 M Silk Rhino All Black leads by 151 places
Warranty
#10,073 vs #10,073
Tied - the same position in the database
Overall
#10,867 vs #10,393
440 M Silk Rhino All Black leads by 474 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 450 M Silk Rhino All Black
11 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 445 M Silk Rhino All Black
10 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 430 M Silk Rhino All Black
One difference: module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 420 M Silk Rhino All Black
One difference: module efficiency
Same manufacturer
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 720 MV
15 differences, the largest is module efficiency
Same manufacturer
FuturaSun
FuturaSun FU 425 M Silk Rhino All Black vs FuturaSun FU 710 MV
15 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU 425 M Silk Rhino All Black or FuturaSun FU 440 M Silk Rhino All Black?
According to our database: FuturaSun FU 440 M Silk Rhino All Black has higher module efficiency (22.02% vs 21.80%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 425 M Silk Rhino All Black and FuturaSun FU 440 M Silk Rhino All Black?
FuturaSun FU 425 M Silk Rhino All Black has a module efficiency of 21.80%, while FuturaSun FU 440 M Silk Rhino All Black is 22.02%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 425 M Silk Rhino All Black use vs FuturaSun FU 440 M Silk Rhino All Black?
FuturaSun FU 425 M Silk Rhino All Black uses N-type cells; FuturaSun FU 440 M Silk Rhino All Black uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 425 M Silk Rhino All Black and FuturaSun FU 440 M Silk Rhino All Black?
FuturaSun FU 425 M Silk Rhino All Black has a 25 years power warranty; FuturaSun FU 440 M Silk Rhino All Black has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.