Astronergy CHSM54RN(DG)/F-BH-530 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-455
VS
The verdict
CHSM54RN(DG)/F-BH-530 leads on the differences that matter
The largest is module efficiency: 1.00 pp more efficient. 9 of 19 comparable parameters are identical.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
10 of 19 parameters
What actually differs
Parameter
CHSM54RN(DG)/F-BH-530
CHSM48RN(DG)(BLH)/F-BH-455
Difference
Module efficiency
23.80 %
22.80 %
1.00 pp more efficient
Rated power
530 Wp
455 Wp
75 W more power
Power density
238.3 Wp/m²
227.7 Wp/m²
10.6 Wp/m² higher
Open-circuit voltage
41.59 V
36.75 V
4.84 V apart
Module area
2.224 m²
1.998 m²
0.226 m² apart
Weight
26.9 kg
24.5 kg
2.4 kg lighter
Weight per kWp
50.8 kg/kWp
53.8 kg/kWp
3.1 kg/kWp lighter
Cell count
108
96
12 cells apart
Voltage at max power
34.60 V
30.65 V
3.95 V apart
Dimensions
1961x1134x30 mm
1762x1134x30 mm
1961x1134x30 mm vs 1762x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
CHSM54RN(DG)/F-BH-530
17,783 kWh
CHSM48RN(DG)(BLH)/F-BH-455
15,266 kWh
Lifetime gap
2,517 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
CHSM54RN(DG)/F-BH-530
CHSM48RN(DG)(BLH)/F-BH-455
Standard test conditions
25 °C
100.0% of rated power
530 W
455 W
Cool, bright day
40 °C
95.7% of rated power
507 W
435 W
Typical summer roof
55 °C
91.3% of rated power
484 W
415 W
Hot roof
70 °C
87.0% of rated power
461 W
396 W
03
Full specification
Parameter
CHSM54RN(DG)/F-BH-530
CHSM48RN(DG)(BLH)/F-BH-455
Difference
Power and efficiency
Rated power
530 Wp
455 Wp
+75 W for CHSM54RN(DG)/F-BH-530
Module efficiency
23.80 %
22.80 %
+1.00 pp for CHSM54RN(DG)/F-BH-530
Power density
238.3 Wp/m²
227.7 Wp/m²
+10.6 Wp/m² for CHSM54RN(DG)/F-BH-530
Open-circuit voltage
41.59 V
36.75 V
4.84 V apart
Voltage at max power
34.60 V
30.65 V
3.95 V apart
Short-circuit current
16.04 A
15.71 A
Effectively the same
Current at max power
15.32 A
14.85 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1961x1134x30 mm
1762x1134x30 mm
1961x1134x30 mm vs 1762x1134x30 mm
Module area
2.224 m²
1.998 m²
0.226 m² apart
Weight
26.9 kg
24.5 kg
-2.4 kg for CHSM48RN(DG)(BLH)/F-BH-455
Weight per kWp
50.8 kg/kWp
53.8 kg/kWp
-3.1 kg/kWp for CHSM54RN(DG)/F-BH-530
Warranty and degradation
Product warranty
25 yrs
25 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
96
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#433
vs
#2,714
CHSM54RN(DG)/F-BH-530 leads by 2,281 places
Power density
#421
vs
#2,888
CHSM54RN(DG)/F-BH-530 leads by 2,467 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#4,171
vs
#7,897
CHSM54RN(DG)/F-BH-530 leads by 3,726 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#2,143
vs
#5,669
CHSM54RN(DG)/F-BH-530 leads by 3,526 places
05
Open the full database
More useful comparisons
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-530 vs Astronergy CHSM54RN(DG)/F-BH-525
One difference: module efficiency
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-530 vs Astronergy CHSM54RN(DG)/F-BH-520
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-530 vs Astronergy CHSM54RN(DG)/F-BH-515
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-530 vs Astronergy CHSM54RN(DG)/F-BH-510
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-455 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-470
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-455 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-465
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Astronergy CHSM54RN(DG)/F-BH-530 or Astronergy CHSM48RN(DG)(BLH)/F-BH-455?
According to our database: Astronergy CHSM54RN(DG)/F-BH-530 has higher module efficiency (23.80% vs 22.80%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Astronergy CHSM54RN(DG)/F-BH-530 and Astronergy CHSM48RN(DG)(BLH)/F-BH-455?
Astronergy CHSM54RN(DG)/F-BH-530 has a module efficiency of 23.80%, while Astronergy CHSM48RN(DG)(BLH)/F-BH-455 is 22.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Astronergy CHSM54RN(DG)/F-BH-530 use vs Astronergy CHSM48RN(DG)(BLH)/F-BH-455?
Astronergy CHSM54RN(DG)/F-BH-530 uses TOPCon cells; Astronergy CHSM48RN(DG)(BLH)/F-BH-455 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Astronergy CHSM54RN(DG)/F-BH-530 and Astronergy CHSM48RN(DG)(BLH)/F-BH-455?
Astronergy CHSM54RN(DG)/F-BH-530 has a 30 years power warranty; Astronergy CHSM48RN(DG)(BLH)/F-BH-455 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Astronergy CHSM54RN(DG)/F-BH-530 and Astronergy CHSM48RN(DG)(BLH)/F-BH-455 bifacial panels?
Both Astronergy CHSM54RN(DG)/F-BH-530 and Astronergy CHSM48RN(DG)(BLH)/F-BH-455 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 41 Astronergy offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.

