Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM54RN(DG)/F-BH-510
VS
The verdict
515 leads on the differences that matter
The largest is module efficiency: 0.30 pp more efficient. 18 of 19 comparable parameters are identical.
See the one differenceHow alike are they
18
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
1 of 19 parameters
What actually differs
Parameter
515
510
Difference
Module efficiency
23.20 %
22.90 %
0.30 pp more efficient
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
515
17,279 kWh
510
17,112 kWh
Lifetime gap
167 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
515
510
Standard test conditions
25 °C
100.0% of rated power
515 W
510 W
Cool, bright day
40 °C
95.7% of rated power
493 W
488 W
Typical summer roof
55 °C
91.3% of rated power
470 W
466 W
Hot roof
70 °C
87.0% of rated power
448 W
443 W
03
Full specification
Parameter
515
510
Difference
Power and efficiency
Rated power
515 Wp
510 Wp
Effectively the same
Module efficiency
23.20 %
22.90 %
+0.30 pp for 515
Power density
231.6 Wp/m²
229.3 Wp/m²
Effectively the same
Open-circuit voltage
41.37 V
41.21 V
Effectively the same
Voltage at max power
34.42 V
34.29 V
Effectively the same
Short-circuit current
15.79 A
15.70 A
Effectively the same
Current at max power
14.96 A
14.87 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1961x1134x30 mm
1961x1134x30 mm
Same
Module area
2.224 m²
2.224 m²
Same
Weight
26.9 kg
26.9 kg
Same
Weight per kWp
52.2 kg/kWp
52.7 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
25 yrs
25 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#1,306
vs
#2,359
515 leads by 1,053 places
Power density
#1,473
vs
#2,343
515 leads by 870 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#5,704
vs
#6,400
515 leads by 696 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#3,194
vs
#3,700
515 leads by 506 places
05
Open the full database
More useful comparisons
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM54RN(DG)/F-BH-530
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM54RN(DG)/F-BH-525
3 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM54RN(DG)/F-BH-520
One difference: module efficiency
Same manufacturer
Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM66N(DG)/F-BH-735
12 differences, the largest is rated power
Same manufacturer
Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM66N(DG)/F-BH-730
12 differences, the largest is rated power
Same manufacturer
Astronergy CHSM54RN(DG)/F-BH-515 vs Astronergy CHSM66N(DG)/F-BH-725
10 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Astronergy CHSM54RN(DG)/F-BH-515 or Astronergy CHSM54RN(DG)/F-BH-510?
According to our database: Astronergy CHSM54RN(DG)/F-BH-515 has higher module efficiency (23.20% vs 22.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Astronergy CHSM54RN(DG)/F-BH-515 and Astronergy CHSM54RN(DG)/F-BH-510?
Astronergy CHSM54RN(DG)/F-BH-515 has a module efficiency of 23.20%, while Astronergy CHSM54RN(DG)/F-BH-510 is 22.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Astronergy CHSM54RN(DG)/F-BH-515 use vs Astronergy CHSM54RN(DG)/F-BH-510?
Astronergy CHSM54RN(DG)/F-BH-515 uses TOPCon cells; Astronergy CHSM54RN(DG)/F-BH-510 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Astronergy CHSM54RN(DG)/F-BH-515 and Astronergy CHSM54RN(DG)/F-BH-510?
Astronergy CHSM54RN(DG)/F-BH-515 has a 30 years power warranty; Astronergy CHSM54RN(DG)/F-BH-510 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Astronergy CHSM54RN(DG)/F-BH-515 and Astronergy CHSM54RN(DG)/F-BH-510 bifacial panels?
Both Astronergy CHSM54RN(DG)/F-BH-515 and Astronergy CHSM54RN(DG)/F-BH-510 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 36 Astronergy offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.