CHSM48RN(DG)(BLH)/F-BH-450 vs JS182MHC120-455 2 of 17 identical Swap Change panels

Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Jinko Solar JS182MHC120-455

Astronergy CHSM48RN(DG)(BLH)/F-BH-450
CHSM48RN(DG)(BLH)/F-BH-450
450 Wp 22.50 % TOPCon Bifacial
VS
JS182MHC120-455
455 Wp 21.02 % PERC Incomplete
The verdict

CHSM48RN(DG)(BLH)/F-BH-450 leads on the differences that matter

The largest is module efficiency: 1.48 pp more efficient. 2 of 17 comparable parameters are identical, with 2 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
2 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 17 parameters
Parameter CHSM48RN(DG)(BLH)/F-BH-450 JS182MHC120-455 Difference
Module efficiency 22.50 % 21.02 % 1.48 pp more efficient
Temperature coefficient -0.290 %/°C -0.340 %/°C 0.050 %/°C better in heat
Power density 225.2 Wp/m² 210.2 Wp/m² 15.0 Wp/m² higher
Performance warranty 30 yrs 25 yrs 5 yrs longer
Open-circuit voltage 36.59 V 41.60 V 5.01 V apart
Module area 1.998 m² 2.165 m² 0.167 m² apart
Short-circuit current 15.61 A 13.73 A 1.88 A apart
Weight per kWp 54.4 kg/kWp 50.5 kg/kWp 3.9 kg/kWp lighter
Cell technology TOPCon PERC TOPCon vs PERC
Weight 24.5 kg 23.0 kg 1.5 kg lighter
Voltage at max power 30.51 V 34.90 V 4.39 V apart
Cell count 96 120 24 cells apart
Current at max power 14.75 A 13.02 A 1.73 A apart
Bifacial Yes No Yes vs No
Dimensions 1762x1134x30 mm 1909x1134x30 mm 1762x1134x30 mm vs 1909x1134x30 mm
02

What it means on a roof

Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
CHSM48RN(DG)(BLH)/F-BH-450
15,098 kWh
JS182MHC120-455
15,102 kWh
Lifetime gap
4 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario CHSM48RN(DG)(BLH)/F-BH-450 JS182MHC120-455
Standard test conditions 25 °C 100.0% of rated power 450 W 455 W
Cool, bright day 40 °C 94.9% of rated power 430 W 432 W
Typical summer roof 55 °C 89.8% of rated power 411 W 409 W
Hot roof 70 °C 84.7% of rated power 391 W 385 W
03

Full specification

Parameter CHSM48RN(DG)(BLH)/F-BH-450 JS182MHC120-455 Difference
Power and efficiency
Rated power 450 Wp 455 Wp Effectively the same
Module efficiency 22.50 % 21.02 % +1.48 pp for CHSM48RN(DG)(BLH)/F-BH-450
Power density 225.2 Wp/m² 210.2 Wp/m² +15.0 Wp/m² for CHSM48RN(DG)(BLH)/F-BH-450
Open-circuit voltage 36.59 V 41.60 V 5.01 V apart
Voltage at max power 30.51 V 34.90 V 4.39 V apart
Short-circuit current 15.61 A 13.73 A 1.88 A apart
Current at max power 14.75 A 13.02 A 1.73 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.340 %/°C +0.050 %/°C for CHSM48RN(DG)(BLH)/F-BH-450
Mechanical
Dimensions 1762x1134x30 mm 1909x1134x30 mm 1762x1134x30 mm vs 1909x1134x30 mm
Module area 1.998 m² 2.165 m² 0.167 m² apart
Weight 24.5 kg 23.0 kg -1.5 kg for JS182MHC120-455
Weight per kWp 54.4 kg/kWp 50.5 kg/kWp -3.9 kg/kWp for JS182MHC120-455
Warranty and degradation
Product warranty 25 yrs - Not published by Jinko Solar
Performance warranty 30 yrs 25 yrs +5 yrs for CHSM48RN(DG)(BLH)/F-BH-450
Annual degradation 0.40 %/yr - Not published by Jinko Solar
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 96 120 24 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,129 panels
Efficiency
#4,281 vs #9,766
CHSM48RN(DG)(BLH)/F-BH-450 leads by 5,485 places
Power density
#4,284 vs #9,810
CHSM48RN(DG)(BLH)/F-BH-450 leads by 5,526 places
Heat behaviour
#2,220 vs #8,846
CHSM48RN(DG)(BLH)/F-BH-450 leads by 6,626 places
Weight
#8,835 vs #3,947
JS182MHC120-455 leads by 4,888 places
Warranty
#21 vs #9,912
CHSM48RN(DG)(BLH)/F-BH-450 leads by 9,891 places
Overall
#6,286 vs #12,190
CHSM48RN(DG)(BLH)/F-BH-450 leads by 5,904 places
05

More useful comparisons

Open the full database
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Astronergy CHSM54RN(DG)/F-BH-530
11 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Astronergy CHSM54RN(DG)/F-BH-525
10 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Astronergy CHSM54RN(DG)/F-BH-520
10 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Astronergy CHSM54RN(DG)/F-BH-515
10 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Astronergy CHSM54RN(DG)/F-BH-510
9 differences, the largest is rated power
Same series, other bin
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 vs Astronergy CHSM48RN(DG)(BLH)/F-BH-470
5 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Astronergy CHSM48RN(DG)(BLH)/F-BH-450 or Jinko Solar JS182MHC120-455?
According to our database: Astronergy CHSM48RN(DG)(BLH)/F-BH-450 has higher module efficiency (22.50% vs 21.02%); Astronergy CHSM48RN(DG)(BLH)/F-BH-450 tolerates heat better (temp coeff -0.290%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Astronergy CHSM48RN(DG)(BLH)/F-BH-450 and Jinko Solar JS182MHC120-455?
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 has a module efficiency of 22.50%, while Jinko Solar JS182MHC120-455 is 21.02%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Astronergy CHSM48RN(DG)(BLH)/F-BH-450 use vs Jinko Solar JS182MHC120-455?
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 uses TOPCon cells; Jinko Solar JS182MHC120-455 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Astronergy CHSM48RN(DG)(BLH)/F-BH-450 and Jinko Solar JS182MHC120-455?
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 has a 30 years power warranty; Jinko Solar JS182MHC120-455 has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Astronergy CHSM48RN(DG)(BLH)/F-BH-450 and Jinko Solar JS182MHC120-455 bifacial panels?
Astronergy CHSM48RN(DG)(BLH)/F-BH-450 is bifacial (captures light from both faces); Jinko Solar JS182MHC120-455 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Compare Astronergy and Jinko Solar as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 37 Astronergy offers · See 145 Jinko Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.