SolarEdge SE3000H (HD‑Wave, single phase) vs STP3.0-3AV-40 (Sunny Tripower 3.0) 8 of 20 identical Swap Change inverters

SolarEdge SE3000H (HD‑Wave, single phase) vs SMA Solar STP3.0-3AV-40 (Sunny Tripower 3.0)

SolarEdge
SolarEdge SE3000H (HD‑Wave, single phase)
3 kW 98.3 % euro Grid-tie
VS
SMA Solar STP3.0-3AV-40 (Sunny Tripower 3.0)
SMA Solar
STP3.0-3AV-40 (Sunny Tripower 3.0)
3 kW 96.5 % euro Grid-tie
The verdict

SolarEdge SE3000H (HD‑Wave, single phase) leads on the differences that matter

The largest is european efficiency: 1.8 pp more efficient. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
8 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 20 parameters
Parameter SolarEdge SE3000H (HD‑Wave, single phase) STP3.0-3AV-40 (Sunny Tripower 3.0) Difference
European efficiency 98.3 % 96.5 % 1.8 pp more efficient
Warranty 25 yrs 5 yrs 20 yrs longer
Max DC voltage 480 V 850 V 370 V apart
Max efficiency 99.2 % 98.2 % 1.0 pp more efficient
Max PV power 4.65 kW 6.00 kW 1.35 kW apart
DC/AC ratio 1.55 2.00 0.45 more oversizing headroom
Weight 7.8 kg 17.0 kg 9.2 kg lighter
Weight per kW 2.6 kg/kW 5.7 kg/kW 3.1 kg/kW lighter
Noise 25 dB 30 dB 5 dB quieter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Max AC current 14.0 A 4.6 A 9.4 A apart
Dimensions 280x370x142 mm 470x435x176 mm 280x370x142 mm vs 470x435x176 mm
02

Full specification

Parameter SolarEdge SE3000H (HD‑Wave, single phase) STP3.0-3AV-40 (Sunny Tripower 3.0) Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.00 kW 3.00 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 230 V Same
Max AC current 14.0 A 4.6 A 9.4 A apart
PV input
Max PV power 4.65 kW 6.00 kW 1.35 kW apart
DC/AC ratio 1.55 2.00 +0.45 for STP3.0-3AV-40 (Sunny Tripower 3.0)
Max DC voltage 480 V 850 V 370 V apart
MPPT voltage range - 140-800 V Not published by SolarEdge
Start voltage - 175 V Not published by SolarEdge
MPP trackers - 2 Not published by SolarEdge
Strings per tracker - 1 Not published by SolarEdge
Max input current per tracker - 12.0 A Not published by SolarEdge
Efficiency
European efficiency 98.3 % 96.5 % +1.8 pp for SolarEdge SE3000H (HD‑Wave, single phase)
Max efficiency 99.2 % 98.2 % +1.0 pp for SolarEdge SE3000H (HD‑Wave, single phase)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 7.8 kg 17.0 kg -9.2 kg for SolarEdge SE3000H (HD‑Wave, single phase)
Weight per kW 2.6 kg/kW 5.7 kg/kW -3.1 kg/kW for SolarEdge SE3000H (HD‑Wave, single phase)
Dimensions 280x370x142 mm 470x435x176 mm 280x370x142 mm vs 470x435x176 mm
Ingress protection IP65 IP65 Same
Cooling natural natural Same
Noise 25 dB 30 dB -5 dB for SolarEdge SE3000H (HD‑Wave, single phase)
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes - Not published by SMA Solar
Integrated DC switch - Yes Not published by SolarEdge
Warranty
Warranty 25 yrs 5 yrs +20 yrs for SolarEdge SE3000H (HD‑Wave, single phase)
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
SolarEdge SE3000H (HD‑Wave, single phase) vs Solis-3P3K-4G
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SolarEdge SE3000H (HD‑Wave, single phase) vs Ginlong Solis S6-GR3P-3K02-NV-ND
12 differences, the largest is european efficiency
Same type, similar size
Growatt
SolarEdge SE3000H (HD‑Wave, single phase) vs Growatt MOD 3000TL3-X
13 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.