STP3.0-3AV-40 (Sunny Tripower 3.0)
vs
SolarEdge SE3000H (HD‑Wave, single phase)
8 of 20 identical
Swap
Change inverters
SMA Solar STP3.0-3AV-40 (Sunny Tripower 3.0) vs SolarEdge SE3000H (HD‑Wave, single phase)
SMA Solar
STP3.0-3AV-40 (Sunny Tripower 3.0)
3 kW
96.5 % euro
Grid-tie
VS
SolarEdge
SolarEdge SE3000H (HD‑Wave, single phase)
3 kW
98.3 % euro
Grid-tie
The verdict
SolarEdge SE3000H (HD‑Wave, single phase) leads on the differences that matter
The largest is european efficiency: 1.8 pp more efficient. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
STP3.0-3AV-40 (Sunny Tripower 3.0)
SolarEdge SE3000H (HD‑Wave, single phase)
Difference
European efficiency
96.5 %
98.3 %
1.8 pp more efficient
Warranty
5 yrs
25 yrs
20 yrs longer
Max DC voltage
850 V
480 V
370 V apart
Max efficiency
98.2 %
99.2 %
1.0 pp more efficient
Max PV power
6.00 kW
4.65 kW
1.35 kW apart
DC/AC ratio
2.00
1.55
0.45 more oversizing headroom
Weight
17.0 kg
7.8 kg
9.2 kg lighter
Weight per kW
5.7 kg/kW
2.6 kg/kW
3.1 kg/kW lighter
Noise
30 dB
25 dB
5 dB quieter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Max AC current
4.6 A
14.0 A
9.4 A apart
Dimensions
470x435x176 mm
280x370x142 mm
470x435x176 mm vs 280x370x142 mm
02
Full specification
Parameter
STP3.0-3AV-40 (Sunny Tripower 3.0)
SolarEdge SE3000H (HD‑Wave, single phase)
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.00 kW
Same
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
230 V
230 V
Same
Max AC current
4.6 A
14.0 A
9.4 A apart
PV input
Max PV power
6.00 kW
4.65 kW
1.35 kW apart
DC/AC ratio
2.00
1.55
+0.45 for STP3.0-3AV-40 (Sunny Tripower 3.0)
Max DC voltage
850 V
480 V
370 V apart
MPPT voltage range
140-800 V
-
Not published by SolarEdge
Start voltage
175 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
12.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
96.5 %
98.3 %
+1.8 pp for SolarEdge SE3000H (HD‑Wave, single phase)
Max efficiency
98.2 %
99.2 %
+1.0 pp for SolarEdge SE3000H (HD‑Wave, single phase)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
17.0 kg
7.8 kg
-9.2 kg for SolarEdge SE3000H (HD‑Wave, single phase)
Weight per kW
5.7 kg/kW
2.6 kg/kW
-3.1 kg/kW for SolarEdge SE3000H (HD‑Wave, single phase)
Dimensions
470x435x176 mm
280x370x142 mm
470x435x176 mm vs 280x370x142 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
30 dB
25 dB
-5 dB for SolarEdge SE3000H (HD‑Wave, single phase)
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by SMA Solar
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
5 yrs
25 yrs
+20 yrs for SolarEdge SE3000H (HD‑Wave, single phase)
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
SMA Solar STP3.0-3AV-40 (Sunny Tripower 3.0) vs Solis-3P3K-4G
8 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SMA Solar STP3.0-3AV-40 (Sunny Tripower 3.0) vs Ginlong Solis S6-GR3P-3K02-NV-ND
11 differences, the largest is european efficiency
Same type, similar size
Growatt
SMA Solar STP3.0-3AV-40 (Sunny Tripower 3.0) vs Growatt MOD 3000TL3-X
12 differences, the largest is european efficiency
Same type, similar size
Growatt
SolarEdge SE3000H (HD‑Wave, single phase) vs Growatt MOD 3000TL3-X2 (Pro)
14 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.