SolarEdge SE50KUS vs Growatt MAX 50KTL3 LV
VS
The verdict
SE50KUS leads on the differences that matter
The largest is max dc voltage: 100 V apart. 6 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
6
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 17 parameters
What actually differs
Parameter
SE50KUS
MAX 50KTL3 LV
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max AC power
50.00 kW
55.50 kW
5.50 kW apart
Max PV power
87.50 kW
75.00 kW
12.50 kW apart
DC/AC ratio
1.75
1.50
0.25 more oversizing headroom
Weight
32.0 kg
82.0 kg
50.0 kg lighter
Weight per kW
0.6 kg/kW
1.6 kg/kW
1.0 kg/kW lighter
Nominal AC voltage
277 V
400 V
123 V apart
Max AC current
139.5 A
80.5 A
59.0 A apart
Ingress protection
NEMA 3R
IP65
NEMA 3R vs IP65
MPPT voltage range
370-1000 V
200-1000 V
370-1000 V vs 200-1000 V
Dimensions
558x328x273 mm
600x860x300 mm
558x328x273 mm vs 600x860x300 mm
02
Full specification
Parameter
SE50KUS
MAX 50KTL3 LV
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.50 kW
5.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
277 V
400 V
123 V apart
Max AC current
139.5 A
80.5 A
59.0 A apart
PV input
Max PV power
87.50 kW
75.00 kW
12.50 kW apart
DC/AC ratio
1.75
1.50
+0.25 for SE50KUS
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
370-1000 V
200-1000 V
370-1000 V vs 200-1000 V
Start voltage
-
250 V
Not published by SolarEdge
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
2
Not published by SolarEdge
Max input current per tracker
-
26.0 A
Not published by SolarEdge
Efficiency
European efficiency
-
98.4 %
Not published by SolarEdge
Max efficiency
-
98.8 %
Not published by SolarEdge
CEC efficiency
97.0 %
-
Not published by Growatt
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
32.0 kg
82.0 kg
-50.0 kg for SE50KUS
Weight per kW
0.6 kg/kW
1.6 kg/kW
-1.0 kg/kW for SE50KUS
Dimensions
558x328x273 mm
600x860x300 mm
558x328x273 mm vs 600x860x300 mm
Ingress protection
NEMA 3R
IP65
NEMA 3R vs IP65
Cooling
forced-air
forced-air
Same
Noise
67 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
SolarEdge SE50KUS vs Huawei SUN2000-50KTL-JPM0
9 differences, the largest is max dc voltage
Same type, similar size
Huawei
SolarEdge SE50KUS vs Huawei SUN2000-50KTL-M0
10 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
SolarEdge SE50KUS vs Solis-50K-HV
11 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Growatt MAX 50KTL3 LV vs Sungrow SG50CX
6 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.