Skip to main content
SE50KUS vs Solis-50K-HV 5 of 16 identical Swap Change inverters

SolarEdge SE50KUS vs Solis-50K-HV

SolarEdge
SE50KUS
50 kW Grid-tie
VS
Solis-50K-HV
Ginlong Solis
Solis-50K-HV
50 kW 98.5 % euro Grid-tie
The verdict

SE50KUS leads on the differences that matter

The largest is max dc voltage: 100 V apart. 5 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
5 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 16 parameters
Parameter SE50KUS Solis-50K-HV Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Max PV power 87.50 kW 60.00 kW 27.50 kW apart
DC/AC ratio 1.75 1.20 0.55 more oversizing headroom
Weight 32.0 kg 61.0 kg 29.0 kg lighter
Weight per kW 0.6 kg/kW 1.2 kg/kW 0.6 kg/kW lighter
Nominal AC voltage 277 V 400 V 123 V apart
Max AC current 139.5 A 66.2 A 73.3 A apart
Ingress protection NEMA 3R IP65 NEMA 3R vs IP65
MPPT voltage range 370-1000 V 200-1000 V 370-1000 V vs 200-1000 V
Dimensions 558x328x273 mm 700x630x357 mm 558x328x273 mm vs 700x630x357 mm
02

Full specification

Parameter SE50KUS Solis-50K-HV Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 277 V 400 V 123 V apart
Max AC current 139.5 A 66.2 A 73.3 A apart
PV input
Max PV power 87.50 kW 60.00 kW 27.50 kW apart
DC/AC ratio 1.75 1.20 +0.55 for SE50KUS
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 370-1000 V 200-1000 V 370-1000 V vs 200-1000 V
Start voltage - 200 V Not published by SolarEdge
MPP trackers - 4 Not published by SolarEdge
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker - - Neither datasheet publishes this
Efficiency
European efficiency - 98.5 % Not published by SolarEdge
Max efficiency - 99.0 % Not published by SolarEdge
CEC efficiency 97.0 % - Not published by Ginlong Solis
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 32.0 kg 61.0 kg -29.0 kg for SE50KUS
Weight per kW 0.6 kg/kW 1.2 kg/kW -0.6 kg/kW for SE50KUS
Dimensions 558x328x273 mm 700x630x357 mm 558x328x273 mm vs 700x630x357 mm
Ingress protection NEMA 3R IP65 NEMA 3R vs IP65
Cooling forced-air - Not published by Ginlong Solis
Noise 67 dB - Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Ginlong Solis
Arc fault protection Yes - Not published by Ginlong Solis
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
SolarEdge SE50KUS vs Huawei SUN2000-50KTL-JPM0
9 differences, the largest is max dc voltage
Same type, similar size
Huawei
SolarEdge SE50KUS vs Huawei SUN2000-50KTL-M0
10 differences, the largest is max dc voltage
Same type, similar size
Growatt
SolarEdge SE50KUS vs Growatt MAX 50KTL3 LV
11 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Solis-50K-HV vs Sungrow SG50CX
6 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.