Growatt MAX 50KTL3 LV vs Sungrow SG50CX
VS
The verdict
SG50CX leads on the differences that matter
The largest is max ac power: 0.50 kW apart. 13 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
13
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 19 parameters
What actually differs
Parameter
MAX 50KTL3 LV
SG50CX
Difference
Max AC power
55.50 kW
55.00 kW
0.50 kW apart
Weight
82.0 kg
62.0 kg
20.0 kg lighter
Max AC current
80.5 A
83.6 A
3.1 A apart
Weight per kW
1.6 kg/kW
1.2 kg/kW
0.4 kg/kW lighter
Ingress protection
IP65
IP66
IP65 vs IP66
Dimensions
600x860x300 mm
645x782x310 mm
600x860x300 mm vs 645x782x310 mm
02
Full specification
Parameter
MAX 50KTL3 LV
SG50CX
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.50 kW
55.00 kW
0.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
80.5 A
83.6 A
3.1 A apart
PV input
Max PV power
75.00 kW
-
Not published by Sungrow
DC/AC ratio
1.50
-
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
250 V
250 V
Same
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
26.0 A
26.0 A
Same
Efficiency
European efficiency
98.4 %
98.4 %
Same
Max efficiency
98.8 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
82.0 kg
62.0 kg
-20.0 kg for SG50CX
Weight per kW
1.6 kg/kW
1.2 kg/kW
-0.4 kg/kW for SG50CX
Dimensions
600x860x300 mm
645x782x310 mm
600x860x300 mm vs 645x782x310 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Growatt MAX 50KTL3 LV vs Huawei SUN2000-50KTL-JPM0
8 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Growatt MAX 50KTL3 LV vs Huawei SUN2000-50KTL-M0
7 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MAX 50KTL3 LV vs Solis-50K-HV
9 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.