SE50K (400V grid) vs MAX 50KTL3 LV 8 of 16 identical Swap Change inverters

SolarEdge SE50K (400V grid) vs Growatt MAX 50KTL3 LV

SolarEdge SE50K (400V grid)
SolarEdge
SE50K (400V grid)
50 kW 98.0 % euro Grid-tie
VS
Growatt MAX 50KTL3 LV
Growatt
MAX 50KTL3 LV
50 kW 98.4 % euro Grid-tie
The verdict

MAX 50KTL3 LV leads on the differences that matter

The largest is max dc voltage: 100 V apart. 8 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
8 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 16 parameters
Parameter SE50K (400V grid) MAX 50KTL3 LV Difference
Max DC voltage 1000 V 1100 V 100 V apart
European efficiency 98.0 % 98.4 % 0.4 pp more efficient
Max AC power 50.00 kW 55.50 kW 5.50 kW apart
Max PV power 87.50 kW 75.00 kW 12.50 kW apart
DC/AC ratio 1.75 1.50 0.25 more oversizing headroom
Max efficiency 98.3 % 98.8 % 0.5 pp more efficient
Max AC current 72.5 A 80.5 A 8.0 A apart
MPPT voltage range 680-1000 V 200-1000 V 680-1000 V vs 200-1000 V
02

Full specification

Parameter SE50K (400V grid) MAX 50KTL3 LV Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 55.50 kW 5.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 72.5 A 80.5 A 8.0 A apart
PV input
Max PV power 87.50 kW 75.00 kW 12.50 kW apart
DC/AC ratio 1.75 1.50 +0.25 for SE50K (400V grid)
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 680-1000 V 200-1000 V 680-1000 V vs 200-1000 V
Start voltage - 250 V Not published by SolarEdge
MPP trackers - - Neither datasheet publishes this
Strings per tracker - 2 Not published by SolarEdge
Max input current per tracker - 26.0 A Not published by SolarEdge
Efficiency
European efficiency 98.0 % 98.4 % +0.4 pp for MAX 50KTL3 LV
Max efficiency 98.3 % 98.8 % +0.5 pp for MAX 50KTL3 LV
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight - 82.0 kg Not published by SolarEdge
Weight per kW - 1.6 kg/kW Not published by SolarEdge
Dimensions - 600x860x300 mm Not published by SolarEdge
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise 67 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by SolarEdge
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
SolarEdge SE50K (400V grid) vs Huawei SUN2000-50KTL-JPM0
7 differences, the largest is european efficiency
Same type, similar size
Huawei
SolarEdge SE50K (400V grid) vs Huawei SUN2000-50KTL-M0
7 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SolarEdge SE50K (400V grid) vs Solis-50K-HV
8 differences, the largest is european efficiency
Same type, similar size
Sungrow
Growatt MAX 50KTL3 LV vs Sungrow SG50CX
6 differences, the largest is max ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.