Skip to main content
SE50K (400V grid) vs SUN2000-50KTL-M0 6 of 13 identical Swap Change inverters

SolarEdge SE50K (400V grid) vs Huawei SUN2000-50KTL-M0

SolarEdge SE50K (400V grid)
SolarEdge
SE50K (400V grid)
50 kW 98.0 % euro Grid-tie
VS
Huawei
SUN2000-50KTL-M0
50 kW 98.5 % euro Grid-tie
The verdict

SUN2000-50KTL-M0 leads on the differences that matter

The largest is european efficiency: 0.5 pp more efficient. 6 of 13 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
6 of 13 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 13 parameters
Parameter SE50K (400V grid) SUN2000-50KTL-M0 Difference
European efficiency 98.0 % 98.5 % 0.5 pp more efficient
Max DC voltage 1000 V 1100 V 100 V apart
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Max efficiency 98.3 % 98.7 % 0.4 pp more efficient
Max AC current 72.5 A 79.4 A 6.9 A apart
MPPT voltage range 680-1000 V 200-1000 V 680-1000 V vs 200-1000 V
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter SE50K (400V grid) SUN2000-50KTL-M0 Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 72.5 A 79.4 A 6.9 A apart
PV input
Max PV power 87.50 kW - Not published by Huawei
DC/AC ratio 1.75 - Not published by Huawei
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 680-1000 V 200-1000 V 680-1000 V vs 200-1000 V
Start voltage - 200 V Not published by SolarEdge
MPP trackers - 6 Not published by SolarEdge
Strings per tracker - 2 Not published by SolarEdge
Max input current per tracker - 22.0 A Not published by SolarEdge
Efficiency
European efficiency 98.0 % 98.5 % +0.5 pp for SUN2000-50KTL-M0
Max efficiency 98.3 % 98.7 % +0.4 pp for SUN2000-50KTL-M0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight - 74.0 kg Not published by SolarEdge
Weight per kW - 1.5 kg/kW Not published by SolarEdge
Dimensions - 555x1075x300 mm Not published by SolarEdge
Ingress protection IP65 IP65 Same
Cooling forced-air natural forced-air vs natural
Noise 67 dB - Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Huawei
Ethernet Yes - Not published by Huawei
Arc fault protection Yes - Not published by Huawei
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
SolarEdge SE50K (400V grid) vs Huawei SUN2000-50KTL-JPM0
7 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SolarEdge SE50K (400V grid) vs Solis-50K-HV
8 differences, the largest is european efficiency
Same type, similar size
Growatt
SolarEdge SE50K (400V grid) vs Growatt MAX 50KTL3 LV
8 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Huawei SUN2000-50KTL-M0 vs Sungrow SG50CX
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.