Skip to main content
SOFAR 4.6KTLM-G3 vs MIN 4600TL-X2 (Pro) 8 of 15 identical Swap Change inverters

SOFAR 4.6KTLM-G3 vs Growatt MIN 4600TL-X2 (Pro)

SOFAR 4.6KTLM-G3
Sofar Solar
SOFAR 4.6KTLM-G3
4.6 kW Grid-tie
VS
Growatt MIN 4600TL-X2 (Pro)
Growatt
MIN 4600TL-X2 (Pro)
4.6 kW 97.5 % euro Grid-tie
The verdict

MIN 4600TL-X2 (Pro) leads on the differences that matter

The largest is max dc voltage: 50 V apart. 8 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
8 of 15 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 15 parameters
Parameter SOFAR 4.6KTLM-G3 MIN 4600TL-X2 (Pro) Difference
Max DC voltage 600 V 550 V 50 V apart
Max input current per tracker 15.0 A 18.0 A 3.0 A more headroom
Max AC current 23.0 A 20.9 A 2.1 A apart
Start voltage 90 V 50 V 40 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 80-550 V 40-550 V 80-550 V vs 40-550 V
Dimensions 344x349x164 mm 350x375x158 mm 344x349x164 mm vs 350x375x158 mm
02

Full specification

Parameter SOFAR 4.6KTLM-G3 MIN 4600TL-X2 (Pro) Difference
AC output
Rated AC power 4.60 kW 4.60 kW Same
Max AC power 4.60 kW 4.60 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 23.0 A 20.9 A 2.1 A apart
PV input
Max PV power - 6.90 kW Not published by Sofar Solar
DC/AC ratio - 1.50 Not published by Sofar Solar
Max DC voltage 600 V 550 V 50 V apart
MPPT voltage range 80-550 V 40-550 V 80-550 V vs 40-550 V
Start voltage 90 V 50 V -40 V for MIN 4600TL-X2 (Pro)
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 15.0 A 18.0 A +3.0 A for MIN 4600TL-X2 (Pro)
Efficiency
European efficiency - 97.5 % Not published by Sofar Solar
Max efficiency - 98.4 % Not published by Sofar Solar
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight - 10.8 kg Not published by Sofar Solar
Weight per kW - 2.3 kg/kW Not published by Sofar Solar
Dimensions 344x349x164 mm 350x375x158 mm 344x349x164 mm vs 350x375x158 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Sofar Solar
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
SOFAR 4.6KTLM-G3 vs GoodWe GW4600-SS
6 differences, the largest is max dc voltage
Same type, similar size
Growatt
SOFAR 4.6KTLM-G3 vs Growatt MIN 4600TL-X
7 differences, the largest is max dc voltage
Same type, similar size
Fronius International
SOFAR 4.6KTLM-G3 vs Fronius Primo 5.0-1 AUS
10 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MIN 4600TL-X2 (Pro) vs Ginlong Solis S6-GR1P4.6K
11 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.