Growatt MIN 4600TL-X2 (Pro) vs SOFAR 4.6KTLM-G3
VS
The verdict
MIN 4600TL-X2 (Pro) leads on the differences that matter
The largest is max dc voltage: 50 V apart. 8 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
8
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 15 parameters
What actually differs
Parameter
MIN 4600TL-X2 (Pro)
SOFAR 4.6KTLM-G3
Difference
Max DC voltage
550 V
600 V
50 V apart
Max input current per tracker
18.0 A
15.0 A
3.0 A more headroom
Max AC current
20.9 A
23.0 A
2.1 A apart
Start voltage
50 V
90 V
40 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
40-550 V
80-550 V
40-550 V vs 80-550 V
Dimensions
350x375x158 mm
344x349x164 mm
350x375x158 mm vs 344x349x164 mm
02
Full specification
Parameter
MIN 4600TL-X2 (Pro)
SOFAR 4.6KTLM-G3
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
4.60 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.9 A
23.0 A
2.1 A apart
PV input
Max PV power
6.90 kW
-
Not published by Sofar Solar
DC/AC ratio
1.50
-
Not published by Sofar Solar
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
40-550 V
80-550 V
40-550 V vs 80-550 V
Start voltage
50 V
90 V
-40 V for MIN 4600TL-X2 (Pro)
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
18.0 A
15.0 A
+3.0 A for MIN 4600TL-X2 (Pro)
Efficiency
European efficiency
97.5 %
-
Not published by Sofar Solar
Max efficiency
98.4 %
-
Not published by Sofar Solar
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
-
Not published by Sofar Solar
Weight per kW
2.3 kg/kW
-
Not published by Sofar Solar
Dimensions
350x375x158 mm
344x349x164 mm
350x375x158 mm vs 344x349x164 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sofar Solar
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt MIN 4600TL-X2 (Pro) vs GoodWe GW4600-SS
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 4600TL-X2 (Pro) vs Growatt MIN 4600TL-X
10 differences, the largest is max input current per tracker
Same type, similar size
Fronius International
Growatt MIN 4600TL-X2 (Pro) vs Fronius Primo 5.0-1 AUS
16 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.