Skip to main content
MIN 4600TL-X2 (Pro) vs MIN 4600TL-X 12 of 22 identical Swap Change inverters

Growatt MIN 4600TL-X2 (Pro) vs Growatt MIN 4600TL-X

Growatt MIN 4600TL-X2 (Pro)
Growatt
MIN 4600TL-X2 (Pro)
4.6 kW 97.5 % euro Grid-tie
VS
Growatt MIN 4600TL-X
Growatt
MIN 4600TL-X
4.6 kW 97.1 % euro Grid-tie
The verdict

MIN 4600TL-X2 (Pro) leads on the differences that matter

The largest is max input current per tracker: 5.5 A more headroom. 12 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
12 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 22 parameters
Parameter MIN 4600TL-X2 (Pro) MIN 4600TL-X Difference
Max input current per tracker 18.0 A 12.5 A 5.5 A more headroom
European efficiency 97.5 % 97.1 % 0.4 pp more efficient
Max AC power 4.60 kW 5.06 kW 0.46 kW apart
Max PV power 6.90 kW 6.44 kW 0.46 kW apart
DC/AC ratio 1.50 1.40 0.10 more oversizing headroom
Start voltage 50 V 100 V 50 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
Max AC current 20.9 A 22.0 A 1.1 A apart
Nominal AC voltage 230 V 220 V 10 V apart
MPPT voltage range 40-550 V 80-550 V 40-550 V vs 80-550 V
02

Full specification

Parameter MIN 4600TL-X2 (Pro) MIN 4600TL-X Difference
AC output
Rated AC power 4.60 kW 4.60 kW Same
Max AC power 4.60 kW 5.06 kW 0.46 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 220 V 10 V apart
Max AC current 20.9 A 22.0 A 1.1 A apart
PV input
Max PV power 6.90 kW 6.44 kW 0.46 kW apart
DC/AC ratio 1.50 1.40 +0.10 for MIN 4600TL-X2 (Pro)
Max DC voltage 550 V 550 V Same
MPPT voltage range 40-550 V 80-550 V 40-550 V vs 80-550 V
Start voltage 50 V 100 V -50 V for MIN 4600TL-X2 (Pro)
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 18.0 A 12.5 A +5.5 A for MIN 4600TL-X2 (Pro)
Efficiency
European efficiency 97.5 % 97.1 % +0.4 pp for MIN 4600TL-X2 (Pro)
Max efficiency 98.4 % 98.4 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 10.8 kg Same
Weight per kW 2.3 kg/kW 2.3 kg/kW Same
Dimensions 350x375x158 mm 350x375x158 mm Same
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty - 5 yrs Not published by Growatt
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Growatt MIN 4600TL-X2 (Pro) vs GoodWe GW4600-SS
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt MIN 4600TL-X2 (Pro) vs Fronius Primo 5.0-1 AUS
16 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MIN 4600TL-X2 (Pro) vs Ginlong Solis S6-GR1P4.6K
11 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.