SOFAR 4.6KTLM-G3 vs Fronius Primo 5.0-1 AUS
VS

Fronius International
Fronius Primo 5.0-1 AUS
4.6 kW
97.1 % euro
Grid-tie
The verdict
Fronius Primo 5.0-1 AUS leads on the differences that matter
The largest is max dc voltage: 400 V apart. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
6
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 16 parameters
What actually differs
Parameter
SOFAR 4.6KTLM-G3
Fronius Primo 5.0-1 AUS
Difference
Max DC voltage
600 V
1000 V
400 V apart
Max input current per tracker
15.0 A
18.0 A
3.0 A more headroom
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Max operating temperature
60 °C
55 °C
5 °C more heat tolerant
Max AC current
23.0 A
21.7 A
1.3 A apart
MPPT voltage range
80-550 V
80-800 V
80-550 V vs 80-800 V
Start voltage
90 V
80 V
10 V earlier start
Strings per tracker
1
2
1 string apart
Dimensions
344x349x164 mm
645x431x204 mm
344x349x164 mm vs 645x431x204 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SOFAR 4.6KTLM-G3
Fronius Primo 5.0-1 AUS
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
23.0 A
21.7 A
1.3 A apart
PV input
Max PV power
-
7.50 kW
Not published by Sofar Solar
DC/AC ratio
-
1.63
Not published by Sofar Solar
Max DC voltage
600 V
1000 V
400 V apart
MPPT voltage range
80-550 V
80-800 V
80-550 V vs 80-800 V
Start voltage
90 V
80 V
-10 V for Fronius Primo 5.0-1 AUS
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
15.0 A
18.0 A
+3.0 A for Fronius Primo 5.0-1 AUS
Efficiency
European efficiency
-
97.1 %
Not published by Sofar Solar
Max efficiency
-
98.1 %
Not published by Sofar Solar
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
21.5 kg
Not published by Sofar Solar
Weight per kW
-
4.7 kg/kW
Not published by Sofar Solar
Dimensions
344x349x164 mm
645x431x204 mm
344x349x164 mm vs 645x431x204 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
55 °C
+5 °C for SOFAR 4.6KTLM-G3
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sofar Solar
Ethernet
-
Yes
Not published by Sofar Solar
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SOFAR 4.6KTLM-G3 vs Growatt MIN 4600TL-X2 (Pro)
7 differences, the largest is max dc voltage
Same type, similar size
GoodWe
SOFAR 4.6KTLM-G3 vs GoodWe GW4600-SS
6 differences, the largest is max dc voltage
Same type, similar size
Growatt
SOFAR 4.6KTLM-G3 vs Growatt MIN 4600TL-X
7 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Fronius Primo 5.0-1 AUS vs Ginlong Solis S6-GR1P4.6K
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.