SMA Solar STP8.0-3AV-40 vs Growatt MOD 8000TL3-X
VS
The verdict
MOD 8000TL3-X leads on the differences that matter
The largest is max dc voltage: 100 V apart. 10 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
10
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 25 parameters
What actually differs
Parameter
STP8.0-3AV-40
MOD 8000TL3-X
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
20.0 A
13.0 A
7.0 A more headroom
European efficiency
97.7 %
98.1 %
0.4 pp more efficient
Max PV power
15.00 kW
12.00 kW
3.00 kW apart
DC/AC ratio
1.88
1.50
0.38 more oversizing headroom
Weight
20.5 kg
14.0 kg
6.5 kg lighter
Weight per kW
2.6 kg/kW
1.8 kg/kW
0.8 kg/kW lighter
Max efficiency
98.3 %
98.6 %
0.3 pp more efficient
Nominal AC voltage
230 V
400 V
170 V apart
Ingress protection
IP65
IP66
IP65 vs IP66
Max AC current
12.1 A
13.3 A
1.2 A apart
MPPT voltage range
260-800 V
140-1000 V
260-800 V vs 140-1000 V
Start voltage
175 V
160 V
15 V earlier start
Strings per tracker
2
1
1 string apart
Dimensions
497x460x176 mm
387x425x178 mm
497x460x176 mm vs 387x425x178 mm
02
Full specification
Parameter
STP8.0-3AV-40
MOD 8000TL3-X
Difference
AC output
Rated AC power
8.00 kW
8.00 kW
Same
Max AC power
8.00 kW
8.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
12.1 A
13.3 A
1.2 A apart
PV input
Max PV power
15.00 kW
12.00 kW
3.00 kW apart
DC/AC ratio
1.88
1.50
+0.38 for STP8.0-3AV-40
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
260-800 V
140-1000 V
260-800 V vs 140-1000 V
Start voltage
175 V
160 V
-15 V for MOD 8000TL3-X
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
20.0 A
13.0 A
+7.0 A for STP8.0-3AV-40
Efficiency
European efficiency
97.7 %
98.1 %
+0.4 pp for MOD 8000TL3-X
Max efficiency
98.3 %
98.6 %
+0.3 pp for MOD 8000TL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
20.5 kg
14.0 kg
-6.5 kg for MOD 8000TL3-X
Weight per kW
2.6 kg/kW
1.8 kg/kW
-0.8 kg/kW for MOD 8000TL3-X
Dimensions
497x460x176 mm
387x425x178 mm
497x460x176 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
30 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SMA Solar STP8.0-3AV-40 vs Growatt MOD 8KTL3-X2(Pro)
15 differences, the largest is max dc voltage
Same type, similar size
Sungrow
SMA Solar STP8.0-3AV-40 vs Sungrow SG8.0RT-20
12 differences, the largest is max dc voltage
Same type, similar size
GoodWe
SMA Solar STP8.0-3AV-40 vs GoodWe GW8000-DT
7 differences, the largest is max pv power
Same type, similar size
Ginlong Solis
Growatt MOD 8000TL3-X vs Ginlong Solis S6-GR3P-8K02-NV-ND
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.