Growatt WIT 50K-HU-US vs Growatt MID 50K-HU
VS
The verdict
MID 50K-HU leads on the differences that matter
The largest is max dc voltage: 100 V apart. 8 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
8
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 23 parameters
What actually differs
Parameter
WIT 50K-HU-US
MID 50K-HU
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
32.0 A
40.0 A
8.0 A more headroom
Max AC power
55.00 kW
50.00 kW
5.00 kW apart
Max PV power
109.20 kW
100.00 kW
9.20 kW apart
Weight
153.0 kg
50.0 kg
103.0 kg lighter
Weight per kW
3.1 kg/kW
1.0 kg/kW
2.1 kg/kW lighter
DC/AC ratio
2.18
2.00
0.18 more oversizing headroom
Max efficiency
98.2 %
98.6 %
0.4 pp more efficient
Nominal AC voltage
480 V
400 V
80 V apart
Max AC current
66.2 A
75.8 A
9.6 A apart
Start voltage
195 V
160 V
35 V earlier start
Ingress protection
IP66/NEMA 4X
IP66
IP66/NEMA 4X vs IP66
MPPT voltage range
180-800 V
200-1000 V
180-800 V vs 200-1000 V
Battery voltage
750-1000V for 3P3W / 820-1000V for 3P4W
600-980 V
750-1000V for 3P3W / 820-1000V for 3P4W vs 600-980 V
Dimensions
1350x850x510 mm
570x680x256 mm
1350x850x510 mm vs 570x680x256 mm
02
Full specification
Parameter
WIT 50K-HU-US
MID 50K-HU
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.00 kW
50.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
400 V
80 V apart
Max AC current
66.2 A
75.8 A
9.6 A apart
PV input
Max PV power
109.20 kW
100.00 kW
9.20 kW apart
DC/AC ratio
2.18
2.00
+0.18 for WIT 50K-HU-US
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
180-800 V
200-1000 V
180-800 V vs 200-1000 V
Start voltage
195 V
160 V
-35 V for MID 50K-HU
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
40.0 A
+8.0 A for MID 50K-HU
Efficiency
European efficiency
-
97.2 %
Not published by Growatt
Max efficiency
98.2 %
98.6 %
+0.4 pp for MID 50K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
750-1000V for 3P3W / 820-1000V for 3P4W
600-980 V
750-1000V for 3P3W / 820-1000V for 3P4W vs 600-980 V
Max charge current
-
42 A
Not published by Growatt
Backup power
-
30.0 kW
Not published by Growatt
Physical
Weight
153.0 kg
50.0 kg
-103.0 kg for MID 50K-HU
Weight per kW
3.1 kg/kW
1.0 kg/kW
-2.1 kg/kW for MID 50K-HU
Dimensions
1350x850x510 mm
570x680x256 mm
1350x850x510 mm vs 570x680x256 mm
Ingress protection
IP66/NEMA 4X
IP66
IP66/NEMA 4X vs IP66
Cooling
forced-air
forced-air
Same
Noise
-
55 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt WIT 50K-HU-US vs GoodWe GW50K-ET-10
13 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt WIT 50K-HU-US vs Ginlong Solis S6-EH3P50K-H
15 differences, the largest is max dc voltage
Same type, similar size
Deye
Growatt WIT 50K-HU-US vs Deye SUN-50K-SG01HP3-EU-BM4
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MID 50K-HU vs Growatt WIT 50K-A-US / WIT 50K-AU-US
7 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.