Skip to main content
MID 50K-HU vs WIT 50K-HU-US 8 of 23 identical Swap Change inverters

Growatt MID 50K-HU vs Growatt WIT 50K-HU-US

Growatt MID 50K-HU
Growatt
MID 50K-HU
50 kW 97.2 % euro Hybrid
VS
Growatt WIT 50K-HU-US
Growatt
WIT 50K-HU-US
50 kW Hybrid
The verdict

MID 50K-HU leads on the differences that matter

The largest is max dc voltage: 100 V apart. 8 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
8 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 23 parameters
Parameter MID 50K-HU WIT 50K-HU-US Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 40.0 A 32.0 A 8.0 A more headroom
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Max PV power 100.00 kW 109.20 kW 9.20 kW apart
Weight 50.0 kg 153.0 kg 103.0 kg lighter
Weight per kW 1.0 kg/kW 3.1 kg/kW 2.1 kg/kW lighter
DC/AC ratio 2.00 2.18 0.18 more oversizing headroom
Max efficiency 98.6 % 98.2 % 0.4 pp more efficient
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 75.8 A 66.2 A 9.6 A apart
Start voltage 160 V 195 V 35 V earlier start
Ingress protection IP66 IP66/NEMA 4X IP66 vs IP66/NEMA 4X
MPPT voltage range 200-1000 V 180-800 V 200-1000 V vs 180-800 V
Battery voltage 600-980 V 750-1000V for 3P3W / 820-1000V for 3P4W 600-980 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Dimensions 570x680x256 mm 1350x850x510 mm 570x680x256 mm vs 1350x850x510 mm
02

Full specification

Parameter MID 50K-HU WIT 50K-HU-US Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 75.8 A 66.2 A 9.6 A apart
PV input
Max PV power 100.00 kW 109.20 kW 9.20 kW apart
DC/AC ratio 2.00 2.18 +0.18 for WIT 50K-HU-US
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 200-1000 V 180-800 V 200-1000 V vs 180-800 V
Start voltage 160 V 195 V -35 V for MID 50K-HU
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 32.0 A +8.0 A for MID 50K-HU
Efficiency
European efficiency 97.2 % - Not published by Growatt
Max efficiency 98.6 % 98.2 % +0.4 pp for MID 50K-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 750-1000V for 3P3W / 820-1000V for 3P4W 600-980 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Max charge current 42 A - Not published by Growatt
Backup power 30.0 kW - Not published by Growatt
Physical
Weight 50.0 kg 153.0 kg -103.0 kg for MID 50K-HU
Weight per kW 1.0 kg/kW 3.1 kg/kW -2.1 kg/kW for MID 50K-HU
Dimensions 570x680x256 mm 1350x850x510 mm 570x680x256 mm vs 1350x850x510 mm
Ingress protection IP66 IP66/NEMA 4X IP66 vs IP66/NEMA 4X
Cooling forced-air forced-air Same
Noise 55 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Growatt MID 50K-HU vs GoodWe GW50K-ET-10
14 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.