Growatt MID 50K-HU vs Growatt WIT 50K-HU-US
VS
The verdict
MID 50K-HU leads on the differences that matter
The largest is max dc voltage: 100 V apart. 8 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
8
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 23 parameters
What actually differs
Parameter
MID 50K-HU
WIT 50K-HU-US
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
40.0 A
32.0 A
8.0 A more headroom
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Max PV power
100.00 kW
109.20 kW
9.20 kW apart
Weight
50.0 kg
153.0 kg
103.0 kg lighter
Weight per kW
1.0 kg/kW
3.1 kg/kW
2.1 kg/kW lighter
DC/AC ratio
2.00
2.18
0.18 more oversizing headroom
Max efficiency
98.6 %
98.2 %
0.4 pp more efficient
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
75.8 A
66.2 A
9.6 A apart
Start voltage
160 V
195 V
35 V earlier start
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
MPPT voltage range
200-1000 V
180-800 V
200-1000 V vs 180-800 V
Battery voltage
600-980 V
750-1000V for 3P3W / 820-1000V for 3P4W
600-980 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Dimensions
570x680x256 mm
1350x850x510 mm
570x680x256 mm vs 1350x850x510 mm
02
Full specification
Parameter
MID 50K-HU
WIT 50K-HU-US
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
75.8 A
66.2 A
9.6 A apart
PV input
Max PV power
100.00 kW
109.20 kW
9.20 kW apart
DC/AC ratio
2.00
2.18
+0.18 for WIT 50K-HU-US
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
200-1000 V
180-800 V
200-1000 V vs 180-800 V
Start voltage
160 V
195 V
-35 V for MID 50K-HU
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
32.0 A
+8.0 A for MID 50K-HU
Efficiency
European efficiency
97.2 %
-
Not published by Growatt
Max efficiency
98.6 %
98.2 %
+0.4 pp for MID 50K-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
750-1000V for 3P3W / 820-1000V for 3P4W
600-980 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Max charge current
42 A
-
Not published by Growatt
Backup power
30.0 kW
-
Not published by Growatt
Physical
Weight
50.0 kg
153.0 kg
-103.0 kg for MID 50K-HU
Weight per kW
1.0 kg/kW
3.1 kg/kW
-2.1 kg/kW for MID 50K-HU
Dimensions
570x680x256 mm
1350x850x510 mm
570x680x256 mm vs 1350x850x510 mm
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Growatt MID 50K-HU vs GoodWe GW50K-ET-10
14 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MID 50K-HU vs Ginlong Solis S6-EH3P50K-H
11 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 50K-HU vs Deye SUN-50K-SG01HP3-EU-BM4
16 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.